JOURNAL BROWSE
Search
Advanced SearchSearch Tips
Performance Analysis of Electronic Personal Dosimeter(EPD) for External Radiation Dosimetry
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
 Title & Authors
Performance Analysis of Electronic Personal Dosimeter(EPD) for External Radiation Dosimetry
Lee, Byoung-Il; Kim, Taejin; Lim, Young-Khi;
  PDF(new window)
 Abstract
As performance of electronic personal dosimeter (EPD) used for auxiliary personal dosimeter in nuclear power plants (NPPs) has been being continuously improved, we investigated application cases in Korea and other countries and also tested it in NPPs to assess the performance of EPD for external radiation dosimetry. Result of performance tests done in domestic NPPs was similar to those obtained by IAEA in cooperation with EURADOS (IAEA-TECDOC-1564). In addition, EPD/TLD dose ratio has shown similar tendency of EPD/Film-badge dose ratio from the research by the Japan Atomic Power Company (JAPC) and EPD provided more conservative value than TLD or Film-badge. Although some EPD's failures have been discussed, EPD has shown continuous improvement according to the report of Institute of Nuclear Power Operation (INPO) and data from domestic NPPs. In conclusion, It is considered that the general performance of EPD is adequate for external radiation dosimetry compared with that of TLD, providing appropriate performance checking procedure and alternative measures for functional failure.
 Keywords
EPD;TLD;Active dosimeter;Passive dosimeter;Nuclear power plant;
 Language
Korean
 Cited by
 References
1.
Health and Safety Executive. The ionising radiations regulations 1999. Health and Safety Executive IRR99. 1999.

2.
International Electrotechnical Commission. Radiation protection instrumentation-measurement of personal dose equivalents Hp(10) and Hp(0.07) for X, gamma, neutron and beta radiations-direct reading personal dose equivalent meters and monitors. International Eletrotechnical Commission IEC 61526. 2005.

3.
IAEA. Intercomparison of personal dose equivalent measurements by active personal dosimeters. International Atomic Energy Agency IAEATECDOC-1564. 2007.

4.
Bolognese-Milsztajn T, Ginjaume M, Luszik-Bhadra M, Vanhavere F, Wahl W, Weeks A. Active personal dosemeters for individual monitoring and other new development. Radiat prot dosim. 2004; 112(1):141-168. crossref(new window)

5.
U.S. Department of Energy. Standard for the performance testing of dosimetry system(DOELAB). U.S. Department of Energy DOE/EH-0027. 1986.