Advanced SearchSearch Tips
Evaluation on Flexural Behavior of Double-tee Slabs with the Least Depth from Optimization Process
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
 Title & Authors
Evaluation on Flexural Behavior of Double-tee Slabs with the Least Depth from Optimization Process
  PDF(new window)
Precast prestressed double-tee slab may be designed by the PCI Design Handbook. It is based on the bridge construction and is required for reorganization for the use of buildings in the domestic construction environments. Much enhanced sections are developed from the reforming process on the determined design factors in the previous experimental works on double tees. Pre-determined shape, reinforcement detail, and 5000 psi concrete strength can not be expected as the best solution for the domestic construction requirements because large amount of use on that systems are anticipated. Flexural tests are performed on four full-scale 12.5m proto-type models, "least depth double tee", which are resulted from the optimization process. Domestic superimposed live load regulation, domestic material properties which is available to product, building design requirements and economy in construction are considered as the main factors to establish. the first two sections are double tee section for 1.2 ton/ market live load with straight and one-point depressed strands and the second two are for 0.6 ton/ parking live load with those strand types. All of the specimens tested fully comply with the flexural strength requirements as specified by ACI 318-95. However, the research has shown that following improved considerations are needed for better result in practice. The locations and method of connection for the lowest bottom mild bar, connection method between precast and cast-in-place concrete, and dap-end reinforcement are need to be improved.
double-tee;slab;flexure;beam test;leath depth;
 Cited by
Flexural Behaviors of Precast Prestressed Rectangular and Inverted-tee Concrete Beams for Buildings,Yu, Sung-Yong;

KCI Concrete Journal, 2002. vol.14. 1, pp.36-42
프리스트레스트 프리캐스트 더블 티형보의 최적설계,유승룡;민창식;

한국콘크리트학회논문집, 1999. vol.11. 6, pp.57-67 crossref(new window)
최적이론에 의하여 설계된 최소 깊이 더블티 댑단부 전단거동 평가,유승룡;김대훈;

한국콘크리트학회논문집, 1999. vol.11. 4, pp.43-54 crossref(new window)
건축용 프리캐스트 프리스트레스트 역티형 보와 직사각형 보의 휨거동 비교,유승룡;

한국콘크리트학회논문집, 2000. vol.12. 6, pp.75-82 crossref(new window)
Building Code Requirements for Reinforced Concrete and Commentary(ACI 318-95), 0000.

(4th ed.), 0000.

철근콘크리트 구조계산 규준 및 해설, 1995.

(2rd.), 1978.

Journal of PCI, 1969. vol.14. 1, pp.62-71

Journal of PCI, 1985. vol.30. 2, pp.172-182

Journal of PCI, 1963. vol.60. 6, pp.719-742

(3rd ed.), 1981. pp.646

Journal of PCI, 1977. vol.22. 3, pp.30-47