Seismic Performance Preliminary Evaluation Method of Reinforced Concrete Apartments with Bearing Wall system
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
 Title & Authors
Seismic Performance Preliminary Evaluation Method of Reinforced Concrete Apartments with Bearing Wall system
Chung, Lan; Woo, Sung-Sik; Choi, Ki-Young; Park, Tae-Won;
  PDF(new window)
 Abstract
In Korea, the seismic design regulations was established since 1988 about regularity scale of structures. However, It was not established about seismic performance and evaluation method as the most existing buildings was constructed before Earthquake-Resistant Design(1988). In this study, for model structures which are 4 units of non-seismic designed apartment and 3 units of seismic designed in Korea performed seismic performance evaluation by suggested KISTC (2004). And the result compare to evaluate Capacity Spectrum Method by using MIDAS Gen and SDS. As a result, we observed that suggested KISTC`s method have overestimated for shear stress and drift index. The purpose of this study provides most conformity seismic performance evaluation process and the appropriate method of calculating the seismic performance index in Korea.
 Keywords
seismic design code;seismic performance;wall-type apartment;shear stress;drift index;
 Language
Korean
 Cited by
1.
국내 공동주택의 지진위험도 현황에 관한 연구,김현진;박태원;정란;

한국안전학회지, 2008. vol.23. 6, pp.100-107
2.
인방보에 마찰형 감쇠기가 설치된 전단벽의 제진효과,정희산;민경원;

한국전산구조공학회논문집, 2009. vol.22. 1, pp.105-115
3.
연결보가 있는 철근콘크리트 내력벽시스템의 내진성능평가 -1990년대 공동주택을 중심으로-,이영욱;채지용;

한국지진공학회논문집, 2011. vol.15. 4, pp.23-31 crossref(new window)
4.
리모델링을 위한 평면확장부 전단강도 평가에 관한 연구,강창구;정란;이상현;박태원;

대한건축학회논문집:구조계, 2011. vol.27. 2, pp.3-10
5.
비내진설계 내력벽식구조물의 슬래브 내진성능 향상방안 연구,황지현;박태원;

한국방재학회 논문집, 2013. vol.13. 4, pp.1-6 crossref(new window)
6.
특수 및 준특수 상세에 따른 철근콘크리트 전단벽의 내진성능평가,오해철;이기학;천영수;김태완;

한국지진공학회논문집, 2014. vol.18. 4, pp.181-191 crossref(new window)
1.
Seismic Performance Evaluations of RC Bearing Wall Systems with Coupling Beams - For Apartment Buildings in 1990s, Journal of the Earthquake Engineering Society of Korea, 2011, 15, 4, 23  crossref(new windwow)
2.
Seismic Performance Evaluation of Reinforced Concrete Shear Wall Systems Designed with Special and Semi-Special Seismic Details, Journal of the Earthquake Engineering Society of Korea, 2014, 18, 4, 181  crossref(new windwow)
3.
Retrofitting Effects of Seismic Resistance Capacity of Existing RC Wall Type Apartment Slab Structures, Journal of korean society of hazard mitigation, 2013, 13, 4, 1  crossref(new windwow)
 References
1.
기상청 홈페이지 자료실, www.kmaneis.go.kr

2.
한국시설안전기술공단, '건축 구조불의 내진 성능 평가 요령', 한국시설안전기술공단, 2004, pp.23-57

3.
권영웅, 홍성걸, 박홍근, 송진규, 김민수, '철근콘크리트 전단벽식 고층건물의 내진 성능 평가에 관한 연구', 한국 구조물진단학회, 추계학술발표논문집, 2002, pp.129-134

4.
정 란, 우운택, 박태원, 나승욱, '전단벽식 구조시스템의 내진 성능 평가 지표 산정', 한국지친공학회 추계학술발 표회 논문집, 6권 1호, 2002, pp.223-230

5.
대한건축학회, 건축구조설계기준, KBC-2005, pp.(3)18-23

6.
ATC, Seismic Evaluation and Retrofit of Concrete Buildings, ATC-40 Report, Applied Technology Council, Redwood City, California, 1996

7.
FEMA, NEHRP Guidelines for the Seismic Rehabilitation of Buildings, FEMA273, Federal Emergency Management Agency, Washington D.C., October, 1997

8.
박태원, 식 구조 공동주택의 내진 성능 보강 효과,단 국대학교 건축공학과 대학원 박사학위 논문, 2005, pp.21-59