To analyse the absorbed radiation dose of the visual organs (eyes, corneas, lenses) during a head CT scan, a with the purpose of radiation protection was designed. Afterwards, the reduction rate of radiation dose when using an eye-shielding was analyzed. The results showed that the higher the energy, the higher the absorbed dose of the eyes. Excluding the head, the organs with high dose were the eyes, corneas, and lenses, respectively. Furthermore, the dose reduction rate before and after shielding was between 38% and 55% for the eyes, and between 35% and 52% for the corneas. In the case of the lenses, when the front was shielded, the reduction rate was 51%, and when the front and the side were shielded simultaneously, the reduction rate was 67%.
Radiation Protection;CT;Visual Organs;Eye-shielding;
 Cited by
D. K. Han, S. G. Ko, H. J. Yang, and M. C. Kim, "The evaluation of image quality and radiation dose in multi detector CT," Korean society of Radiological science, Vol.30, pp.129-138, 2007.

백철오, 한만석, "CT검사 시 다양한 매개변수와 환자의 불안 요인에 관한 연구," 방사선기술과학, 제34권, 제2호, 2011.

이정근, 장영일, 장성주, "MDCT의 3차원 볼륨렌더링을 이용한 복강축과 위창자간막동맥의 변위형태에 관한연구," 방사선기술과학, 제36권, 제2호, 2013.

오정권, 비이온성 이량체 조영제 투여가 신장 배설 기능에 미치는 영향, 부산대학교 일반대학원, 석사학위논문, 2000.

조유진, 조평곤, "Liver CT 검사에서 프로토콜 변화에 따른 선량 감소와 영상의 질 개선에 관한 연구," 방사선기술과학, 제38권, 제2호, 2015.

이명철, "대한방사선방어학회 30년사," 대한방사선방어학회, 2007

J. S. P. Tan, K. L. Tan, J. C. L. Lee, C. M. Wan, J. L. Leong, and L. L. Chan, "Comparison of Eye Lens Dose on Neuroimaging Protocols between 16- and 64-Section Multidetector CT: Achieving the Lowest Possible Dose," American Society of Neuroradiology, Published October 14, 2008 as 10.3174/ajnr.A1327, 2009.

M. Y. Jung, D. C. Kweon, and S. l. Kwon, "Effectiveness of Bismuth Shield to Reduce Eye Lens Radiation Dose Using the Photoluminescence Dosimetry in Computed Tomography," Korean society of Radiological science, Vol.32, pp.307-312, 2009.

The 2007 recommendations of the international commission on radiological protection. Oxford: Elsevier, 2007.

IAEA. IAEA Cataract study ; IAEA activity on Retrospective Evaluation of Lens Injuries and Dose(RELID), 2008.

J. R. Bristol, "Comparison of Eye Plaque Dosimetry using Deterministic and Monte Carlo Methods," Oregon State University, Degree of Master of Science, 2010.

M. Cristy and K. F. Eckerman "Specific Absorbed Fractions of Energy at Various Ages from Internal Photon sources," ORNL/TM-8381, Oak Ridge National Laboratory, Oak Ridge, TN, USA, 1987.

J. H. Kim, C. S. Kim, C. S. Lim, and J. Y. Chung, "Evaluation of radiation exposure upon visual organs during a head CT scan," Journal of Nuclear Science and Technology, Vol.49, No.7, pp.754-759, 2012. crossref(new window)