The Distal Filling Effects on Hip Jont Function in Cementless Total Hip Replacement
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
 Title & Authors
The Distal Filling Effects on Hip Jont Function in Cementless Total Hip Replacement
;;;;
  PDF(new window)
 Abstract
In cementless total hip replacement(THR), an initial stability of the femoral component is important to long term fixation of femoral stem. The intial stability has close relationship with the relative displacement of prosthessis and sponge bone at the proximal of femur. After implantation of the proshesis, the surrounding bone is partially shielded from load carrying and starts to resorb. Stress shielding is the cause of the loss of proximal bone. Assessing stress distribution of femur is important to predict stress shielding. The initial stability and the stress shielding were investigated for two loading conditions approximating a single leg stance and a stair climbing. Three types of stems were studied by the finite element method to analyze the biomechanical effects of distal filling of cementless femoral stems. Three types of stems empolyed are a distal filling stem, a distal flexible stem, and a distal tapered stem.
 Keywords
Total Hip Replacement(인공 고관절 대치술);Distal Filling Stem(원부의 압박형 스템);Distal Flexible Stem(원위부 비압박형 스템);Distal Tapered Stem(원위부가 짧은 비압박형 스템);Stress Shielding(응력 차단);Finite Element Analysis(유한요소해석);
 Language
Korean
 Cited by
 References
1.
Biegler, F. B., Reuben, J. D., Harrigan, T. P., Hou, F. J. and Akin, J. E., 1995, 'Effect of Porous Coating and Loading Conditions on Total Hip Femoral Stem Stability,' J Arthroplasty, Vol. 10, No. 6

2.
채수원, 정중환, 김성곤, 1998, '무시멘트형 인공고관절에서 직선형 및 곡선형 대퇴스템의 생역학적 특성,' 대한기계학회 논문집 A권, 제22권, 제5호

3.
Keyak, J. H., Rossi, S. A., Jones, K. A., and Skinner, H. B., 1998, 'Prediction of Femoral Fracture Load Using Automated Finite Element Modeling,' J. Biomechanics, Vol. 31, pp. 125-133 crossref(new window)

4.
Rohlman, A., Cheal, E. J., Hayes, W. C. and Bergmann, G., 1988, 'A Non Linear Finite Element Analysis of Interface Conditions in Porous Coated Hip Endoprostheses,' J. Biomechanics, Vol. 21, pp. 605-611 crossref(new window)

5.
Van Rietbergen, B., Huiskes, R., Weinans, H., Sumner, D. R., Turner, T. M. and Galante, J. O., 1993, 'The Mechanism of Bone Remodeling And Resorption Around Press-Fitted THA Stems,' J Biomechanics, Vol. 26, No. 4, pp. 369-382 crossref(new window)

6.
Huiskes, R., Weinans, H., Van Rietbergen, B., 1992, 'The Relationship Between Stress Shielding and Bone Resorption Around Total Hip Stems and the Effects of Flexible Materials,' Clin Orthop, Vol. 274, pp. 124-134

7.
Burke, D. W., O'Connor, D. O., Zalenski, E. B., Jasty, M. and Harris, W. H., 1991, 'Micromotion of Cemented and Uncemented Femoral Components,' J. Bone Joint Sur[Br], Vol. 73-B, No. 1, pp. 33-37

8.
Skinner, H. B., Kilgus, D. J., Keyak, J., Shimaoka, E. E., Kim, A. S. And Tipton, J. S., 1994, 'Correlation of Computed Finite Element Stresses to Bone Density After Remodeling Around Cementless Femoral Implants,' Clinical Orthopaedics And Related Research, No. 305, pp. 178-189

9.
Mann, K. A., Bartel, D. L., Wright, T. M. and Hurstein, A. H., 1995, 'Coulomb Frictional Interfaces in Modeling Cemented Total Hip Replacements : A More Realistic Model,' J. Biomechanics, Vol. 28, No. 9, pp. 1067-1078 crossref(new window)

10.
Rubin, P. J., Rakotomanana, R. L., Leyvraz, P. F., Zysset, P. K., Curnier, A. and Heegard, J. H., 1993, 'Friction Interface Micromotions and Anisotropic Stress Distribution in a Femoral Total Hip Component,' J. Biomechanics, Vol. 26 pp. 725-38

11.
Keaveny, T. M. and Bartel, D. L., 1992, ' Mechanical Consequence of Bone Ingrowth and Fibrous Tissue Encapsulation for a Cementless Hip Prothesis in the Long-Term,' Trans 38th ORS, Vol. 17, p. 73

12.
Harrigan, T. P. and Harris, W. H., 1991, 'A Three-Dimensional Non-Linear Finite Element Study of the Effect of Cement-Prosthesis Debonding Incemented Femoral Total Hip Components,' J. Biomechanics, Vol. 24, pp. 1047-1058 crossref(new window)

13.
Davy, D. T., Kotzar, G. M., Brown, R. H., Heiple, K. G., Berilia, J. and Burstein, A. H., 1988, 'Telemetric Force Measurement Across the Hip After Total Arthroplasty,' J. Bone Joint Surg, Vol. 70-A, pp. 45-50

14.
Keaveny, T. M. and Bartel, D. L., 1993, 'Effects of Porous Coating and Collar Support on Early Load Transfer for a Cementless Hip Prosthesis,' J. Biomechanics, Vol. 26, pp. 1355-1368 crossref(new window)