Measurements of Soot Volume Fraction Using Laser Induced Incandescence
Lee, Seung; Lee, Sang-Hup; Lee, Byeong-Jun; Hahn, Jae-Won;
  PDF(new window)
Laser induced incandescence (LII) method is frequently used to measure soot volume fraction in flames. In this study, experiments were performed to measure soot volume fraction in coaxial diffusion flame using LII method and calibrated with laser scattering/extinction method. The effects of laser intensity (>), laser wavelength (532nm, 1064nm) and detection wavelength (400nm, 600nm) on the LII signal were investigated. On the range of there were no effects of laser intensity on LII signal. Except these ranges, LII signal was increased with laser intensity. For the long gate width, the LII signals of the higher laser intensity (>) cases had better correlation with soot volume fraction which were measured by laser extinction method compared with lower laser intensity cases. The errors of 2-dimensional cases at the calibration height were approximately 50% regardless of laser wavelength
Laser Induced Incandescence;Laser Scattering/Extinction;Soot Volume Fraction;
 Cited by
주기적 연료 공급이 비애혼합 화염 특성에 미치는 영향에 관한 연구,이상협;전대현;이병준;

대한기계학회논문집B, 2002. vol.26. 1, pp.94-100 crossref(new window)
Eckbreth A. C., 1977. 'Effects of Laser-Modulated Particle Incandescence on Raman Scattering Diagnostics,' J. of applied physics, Vol. 48, pp. 4473-4479 crossref(new window)

Melton L. A., 1984. 'Soot Diagnostics Based on Laser Heating,' Applied Optics, Vol. 23, pp. 2201-2208

Hefedt D. L., 1993. 'Real-Time Soot Concentration Measurement Technique for Engine Exhaust Streams,' SAE technical paper No. 930075, pp. 33-45

Quey B., Lee T. W., Ni T., and Santoro R. J., 1994. 'Spatially Resolved Measurements of Soot Volume Fraction Using LII,' Combustion and Flame, Vol. 97, pp. 384-392 crossref(new window)

Ni T., Pinson J. A., Gupta S., and Santoro R. J., 1995. '2-Dim Imaging of Soot Volume Fraction by the Use of LII,' Applied Optics, Vol. 34, pp. 7073-7091

Santoro R. J., Semerjian H. G., and Dobbins R. A., 1983. 'Soot Particle Measurements in Diffusion Flames,' Combustion and Flame. Vol 51, pp 203-218 crossref(new window)

Kosaka H., Nishigaki T., Kamimoto T., and Harada S., 1995. 'A Study on Soot Formation and Oxidation in an Unsteady Spray Flame Via Laser Induced Incandescence and Scattering Techniques,' SAE technical paper No. 952451, pp. 1390-1399

Dec J. E., and Zur Loye A. O., and Diebers D. L., 1995. 'Soot Distribution in a D.I. Diesel Engine Using 2-D Laser Induced Incandescence Imaging,' SAE technical paper No. 950456, pp. 51-59

Dec J. E., and Espey C., 1993. 'Imaging and Early Soot Formation in a Di Engine Using 2-Dim Laser Induced Incandescence Imaging,' SAE technical paper No. 910224, pp. 1-13

Choi M. Y., Jensen K. A., 1998. 'Calibration and Correlation of LII for Soot Volume Fraction Measurements,' Combustion and Flame. Vol 112, pp. 485-491 crossref(new window)

황준영, 1995, '확산 화염의 매연특성에 관한 실험적 연구,' 서울대학교 대학원 석사학위논문

Vaglieco B. M., Beretta F., and D'alessio A., 1990. 'In Situ Evaluation of the Soot Refractive Index in the Uv-Visible from The Measurement at the Scattering and Extinction Coefficients in Rich Flames,' Combustion and Flame, Vol. 79, pp. 259-271 crossref(new window)

Bengtsson P. E., Alden M., 1995. 'Soot-Visualization Strategies Using Laser Techniques Laser-Induced Fluorescence in C//2 from Laser-Vaporized Soot and Laser-Induced Soot Incandescence,' Applied Physics. B Vol. 60, pp. 51-59 crossref(new window)