A Study on Hydraulic Modifications of Low-Pressure Membrane Inlet Structure with CFD and PIV Techniques
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
 Title & Authors
A Study on Hydraulic Modifications of Low-Pressure Membrane Inlet Structure with CFD and PIV Techniques
Oh, Jeong Ik; Choi, Jong-Woong; Lim, Jae-Lim; Kim, Donggil; Park, No-Suk;
  PDF(new window)
 Abstract
This study was conducted to suggest hydraulic modification for improving evenness of inlet flow distribution into side stream type low-pressure MF (microfiltration) module using CFD (computational fluid dynamics) simulation and PIV (particle image velocimetry) techniques. From the results of CFD simulation for various typed inlet structure, it was investigated that installing internal orifice baffle in inlet the distribution channel could improve the evenness of inlet flow distribution over about 40%. Also, from the results of PIV measurements which were carried out for verifying the CFD simulation, it was observed that the momentum of the water body coming from the opposite side of the inlet was relatively larger. This momentum would generate strong shear force in the near of inlet side wall. On the other hands, occurrence of dead zone and eddy flow was confirmed in the opposite side.
 Keywords
Evenness of Flow Distribution;Side Stream Type MF Module;Hydraulic Modification;Computational Fluid Dynamics (CFD);Particle Image Velocimetry (PIV);
 Language
Korean
 Cited by
1.
하수처리장 고도처리공정에 적용된 네오하이드로포일 교반기의 성능 평가,주윤식;손건태;배영준;구정은;김준영;이승환;

한국수처리학회지, 2016. vol.24. 2, pp.53-62 crossref(new window)
 References
1.
Li, Y. L. and Tung, K. L., "CFD simulation of fluid flow through spacer-filled membrane module: selecting suitable cell types for periodic boundary conditions," Desalination, 233, 351-358(2008). crossref(new window)

2.
Owen, G., Bandi, M., Howell, J. A. and Churchouse, S. J., "Economic assessment of membrane process for water and waste water treatment," J. Membr. Sci., 102, 77-91(1995). crossref(new window)

3.
Guo, H., Wyart, Y., Perot, J., Nauleau, F. and Moulin, P., "Low-pressure membrane integrity tests for drinking water treatment: A review," Water Res., 44, 41-57(2010). crossref(new window)

4.
David, H., Furukawa, P. E. and Ch, E., "NWRI Final Project Report: a Global Perspective of Low Pressure Membrane," USA, California(2008).

5.
Brehant, A., Glucina, K., Lemoigne, I. and Laine, J. M., Risk Mangement Approach for Monitoring UF Membrane Integrity and Experimental Validation using MS2-phages. IWA World Water Congress, Austria Vienna(2008).

6.
Huang, H., Schwab, K. and Jacangelo, J. G., "Pretreatment for Low Pressure Membrane in Water Treatment: A Review," Environm. Sci. Technol., 43(9), 3011-3019(2009). crossref(new window)

7.
Zhu, B. T., Clifford, D. A. and Chellam, S., "Virus removal by iron coagulation-microfiltration." Water Res., 39(20), 5153-5161(2005). crossref(new window)

8.
Yan, M., Wang, D., Ni, J., Qu, J., Chow, C. W. K. and Liu, H., "Mechanism of natural organic matter removal by polyaluminum chloride: Effect of coagulant particle size and hydrolysis kinetics," Water Res., 42(3), 3361-3370(2008). crossref(new window)

9.
Kim, J., Cai, Z. and Benjamin, M. M., "Effects of adsorbents on membrane fouling by natural organic matter," J. Membr. Sci., 310(1-2), 356-364(2008). crossref(new window)

10.
Clark, M. M., Ahn, W. Y., Li, X., Sternisha, N. and Riley, R. L., "Formation of polysulfone colloids for adsorption of natural organic foulants," Langmuir, 21(16), 7207-7213 (2005). crossref(new window)

11.
Plummer, J. D. and Edzwald, J. K., "Effects of chlorine and ozone on algal cell properties and removal of algae by coagulation," J. Water Supply Res. Technol.-AQUA-, 51(6), 307-318(2002). crossref(new window)

12.
Wang, X., Wang, L., Liu, Y. and Duan, W., "Ozonation pretreatment for ultrafiltration of the secondary effluent," J. Membr. Sci., 287(2), 187-191(2007). crossref(new window)

13.
Koh, M., Clark, M. A. and Howe, K. J., "Filtration of lake natural organic matter: Adsorption capacity of a polypropylene microfilter," J. Membr. Sci., 256(1-2), 169-175 (2005).

14.
Sakol, D. and Konieczny, K., "Application of coagulation and conventional filtration in raw water pretreatment before microfiltration membranes," Desalination, 162(1-3), 61-73 (2004). crossref(new window)

15.
Park, N. S., Kim, S., Lee, Y. and Wang C., "Effects of Longitudinal Baffles on Particles settling in a Sedimentation Basin," Water Sci. Technol., 69(6), 1212-1218(2014). crossref(new window)

16.
Kim, S., Park, N. S., Jeong, W. and Wang, C., "Process control systems of granular media filter considering daily flow-rate fluctuation," Desalination and Water Treat., 51(37-39), 6978-6984(2013). crossref(new window)

17.
Lee, A., Park, N. S., Kim, S. and Kim, N., "Physical modification to improve a channel's flow distribution," Korean J. Chem. Eng., 29(2), 201-208(2012). crossref(new window)

18.
ANSYS, ANSYS CFX Tutorials, ANSYS, Inc., Southpointe U.S.A(2009).

19.
Rajendran, V. P. and Patel, V. C., "Measurement of Vortices in Model Pump Intake Bay by PIV," J. Hydraulic Eng., ASCE, 126(5), 322-334(2000). crossref(new window)