Study on Discharge Characteristics of Water Pollutants among Industrial Wastewater per Industrial Classification and the Probability Evaluation
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
 Title & Authors
Study on Discharge Characteristics of Water Pollutants among Industrial Wastewater per Industrial Classification and the Probability Evaluation
Ahn, Tae-ung; Kim, Won-ky; Son, Dae-hee; Yeom, Ick-tae; Kim, Jae-hoon; Yu, Soon-ju;
  PDF(new window)
 Abstract
Information on the lists of pollutants from industrial wastewater discharge are essential not only to specify the key pollutants to be managed in permission process but to design the treatment facilities by the dischargers. In this study, wastewater quality analysis was conducted for three industrial categories including the specified hazardous water pollutants. The general description of the wastewater occurrence, major sources, treatment facilities are also investigated to obtain integrated database on the pollutant inventories for the industrial categories. In addition Based on the analysis of raw wastewater and final effluent, the detected pollutant items are confirmed by analyzing their presence in the raw or supplement materials, the potential of formation as byproducts, and the possibility of inclusion as impurities. The three industrial categories include petrochemical basic compounds, basic organic compounds, and thermal power generation. The water pollutants emitted from petrochemical basic compound manufacturing facilities are 31 items including 16 specified hazardous water pollutants. Basic organic compound manufacturing facilities discharge 30 kinds of pollutants including 14 specified hazardous water pollutants. Thermal power generation facilities emit 20 pollutants, 8 specified hazardous water pollutants among them. These substances were decided as emission inventories of water pollutants finally through the probability evaluation. The compounds detected for each categories are screened through investigation on the possible causes of their occurrence and confirmed as the final water pollutant inventories.
 Keywords
Industrial Wastewater;Water Pollutants;Specified Hazardous Water Pollutants;Discharge Inventories;Probability Evaluation;
 Language
Korean
 Cited by
 References
1.
National Institute of Environmental Research (NIER), "Monitoring of hazardous chemicals for wastewater discharge facilities in the Nakdong river basin(II)," p. 1(2011).

2.
Kwon, O. S., Jung, J. Y., Heo, T. Y., Jeon, H. B., Lee, Y. H. and Park, S. M., "Establishment of effluent limitation based on Wastewater Characteristics and treatment technology," J. Korean Soc. Water Environ., 28(6), 804-812(2012).

3.
Kim, M. I. and Kang, M. A., "Monitoring of Micro Noxious Chemicals Caused by Fiber and Chemistry Industrial Wastewater on the Nakdong River Water System," J. Korean Soc. Eng. Geol., 16(2), 145-152(2006).

4.
Ministry of Environment (MOE), "Improvement of Wastewater Management System for Industry, Ministry of Environment," pp. 3-19(2008).

5.
Ministry of Environment (MOE), "Status of the Priority Water Pollutant and Management in Korea," p. 1-3(2013).

6.
Ministry of Environment (MOE), "Survey of Specific Hazardous Substances from Wastewater by Industrial Wastewater Treatment Plants," p. 1-5(2012a).

7.
U. S. EPA, "NPDES Permit Writers' Manual," pp. 20-35 (2010).

8.
National Institute of Environmental Research (NIER), "Estimation on Pollutant Unit Mass from an Industrial Wastewater Discharging Facility," p. 2-14(2013).

9.
Lee, I. S., Sim, W. J., Oh, J. E., Kim, C. W., Jang, Y. S. and Yoon, Y. S., "Evaluation of Removal Efficiencies of Micro pollutants in Wastewater Treatment Plants," Korean Soc. Environ. Eng., 29(2), 214-219(2007).

10.
Ministry of Environment (MOE), "Water Quality and Ecosystem Conservation Act, Ministry of Environment," p. 246 (2010).

11.
Ha, D. H. and Jung, J. Y., "Evaluation of Organics and Inorganics Removal of Physicochemical Pre-treatment Processes for Reuse of Metal Industry Wastewater," Korean Soc. Environ. Eng., 35(3), 226-232(2013). crossref(new window)

12.
European Commission., "Integrated Pollution Prevention and Control (IPPC) Reference Document on Best Available Techniques in the Large Volume Organic Chemical Industry," p. 1-7(2003).

13.
European Commission., "Integrated Pollution Prevention and Control (IPPC) Reference Document on Best Available Techniques for the Manufacture of Organic Fine Chemicals," pp. 1-14(2006a).

14.
European Commission, "Integrated Pollution Prevention and Control (IPPC) Reference Document on Best Available Techniques for Large Combustion Plants," pp. 1-11(2006b).

15.
Ministry of Environment (MOE), "Effluent limitation Standard, Enforcement Regulation in Water Quality and Ecosystem Conservation Act,"(2012b).

16.
National Institute of Environmental Research (NIER), "BAT Assessment and Unit Load Counting for Wastewater Treatment Processes," pp. 5-19(2004).

17.
Kim, J. H., "Study on establishment of the industrial wastewater effluent limitations based on best practicable control technology currently available," J. Korean Soc. Water Environ., 28(4), 608-614(2012).

18.
Jung, Y. H., Kim, S. K., Shin, S. K., Kang, I. G., Lee, J. I., Lee, W. S. and Lee, J. B., "A Study on the Characteristic Trace Organic Pollutants in the Industrial Wastewater," The Korean Soc. Anal. Sci., 11(1), 62-72(1998).

19.
Ministry of Environment (MOE). "Analysis of environmental improvement effect of industrial wastewater management policies," pp. 16-20(2003).