JOURNAL BROWSE
Search
Advanced SearchSearch Tips
Performance Analysis of Two-stage Compression Refrigeration System with Internal Heat Exchanger Applied Various Refrigerants
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
 Title & Authors
Performance Analysis of Two-stage Compression Refrigeration System with Internal Heat Exchanger Applied Various Refrigerants
Yoon, Jung-In; Heo, Seong-Kwan; Je, Jae-Myun; Jeon, Min-Ju; Son, Chang-Hyo; Moon, Jung-Hyun;
  PDF(new window)
 Abstract
In this paper, cycle performance analysis of two-stage compression and one-stage expansion refrigeration system applied various refrigerants is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include degree of superheating and subcooling, compressor efficiency, evaporation temperature, condensing temperature, mass flow rate ration into inter-cooler, effectiveness of internal heat exchanger. The main results were summarized as follows : The COP of two-stage compression and 1-stage expansion refrigeration system increases with the increasing subcooling, mass flow rate ration of inter-cooler, evaporation temperature, but decreases with the increasing condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of two-stage compression and 1-stage expansion using substitute refrigerant have an effect on COP of this system. The COP of alternative refrigerants was higher than the COP of R22 in this study, although the COP of some mixed refrigerants were lower than COP of R22.
 Keywords
Two-stage compression and one-stage expansion refrigeration system;Alternative refrigerant;Internal heat exchanger;COP;Mass flow-rate;
 Language
Korean
 Cited by
 References
1.
K. S. Roh, 2012, "Performance Analysis of 2-Stage Compression and 1-Stage Expansion Refrigeration System using Alternative Natural Refrigerants", Journal of the Korean Institute of Gas, Vol. 16, No. 1.

2.
H. K. Ku, 2014, "Performance Analysis of R-1270(Propylene) Refrigeration ystem Using Internal Heat Exchanger", Journal of the Korean Society for Power System Engineering, Vol. 18, No. 4, pp. 36-42.

3.
K. S. Rog and J. R. Kim, 2013, "Performance Analysis of Two-stage Compression and Two-stage Expansion Refrigeration System using Freon Refrigerants", Vol. 25, No. 2, pp. 301-306. crossref(new window)

4.
C. W. Park, D. G. Lee, S. K. Choi and C. D. Kang, 2009, "Two-Stage compression cycle operating with alternative refrigerant using by EES program", pp. 533-538.