Design of DC Side Voltage and Compensation Analysis of THD for Shunt Power Quality Controller under System Load of Rectifier with R-L Load
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
 Title & Authors
Design of DC Side Voltage and Compensation Analysis of THD for Shunt Power Quality Controller under System Load of Rectifier with R-L Load
Zhao, Guopeng; Han, Minxiao;
  PDF(new window)
 Abstract
For a shunt power quality controller (SPQC) the DC side voltage value which is closely related to the compensation performance is a significant parameter. Buy so far, very little discussion has been conducted on this in a quantitative manner by previous publications. In this paper, a method to design the DC side voltage of SPQC is presented according to the compensation performance in the single-phase system and the three-phase system respectively. First, for the reactive current and the harmonic current compensation, a required minimal value of the DC side voltage with a zero total harmonic distortion (THD) of the source current and a unit power factor is obtained for a typical load, through the equivalent circuit analysis and the Fourier Transform analytical expressions. Second, when the DC side voltage of SPQC is lower than the above-obtained minimal value, the quantitative relationship between the DC side voltage and the THD after compensation is also elaborated using the curve diagram. Hardware experimental results verify the design method.
 Keywords
Power quality;Shunt power quality controller (SPQC);DC side voltage;Total harmonic distortion (THD);Compensation performance;Harmonics;
 Language
English
 Cited by
1.
Time-resolved analysis and optical diagnostics of Trichel corona in atmospheric air, Journal of Physics D: Applied Physics, 2016, 49, 24, 245206  crossref(new windwow)
2.
Hierarchical NiO–In2O3microflower (3D)/ nanorod (1D) hetero-architecture as a supercapattery electrode with excellent cyclic stability, J. Mater. Chem. A, 2016, 4, 13, 4820  crossref(new windwow)
3.
Realization of Unified Power Quality Conditioner for Mitigating All Voltage Collapse Issues, Circuits and Systems, 2016, 07, 06, 779  crossref(new windwow)
 References
1.
Ji-Ho Park and Young-Sik Baek, “Coordination Control of Voltage Between STATCOM and Reactive Power Compensation Devices in Steady-State,” J. Electr. Eng. Technol., vol. 7, no. 5, pp. 689-697, Sep. 2012. crossref(new window)

2.
Wen-Hao Zhang, Seung-Jae Lee and Myeon-Song Choi, “Setting Considerations of Distance Relay for Transmission Line with STATCOM,” J. Electr. Eng. Technol., vol. 5, no. 4, pp. 522-527, Dec. 2010. crossref(new window)

3.
Yash Pal, A. Swarup and Bhim Singh, “A Novel Control Strategy of Three-phase, Four-wire UPQC for Power Quality Improvement,” J. Electr. Eng. Technol., vol. 7, no. 1, pp. 1-8, Jan. 2012. crossref(new window)

4.
Jun-Bo Sim, Ki-Cheol Kim, Rak-Won Son and Joong-Ki Oh, “Ride-through of PMSG Wind Power System Under the Distorted and Unbalanced Grid Voltage Dips,” J. Electr. Eng. Technol., vol. 7, no. 6, pp. 898-904, Nov. 2012. crossref(new window)

5.
Sung-Eun Lee, Dong-Jun Won and Il-Yop Chung, “Operation Scheme for a Wind Farm to Mitigate Output Power Variation,” J. Electr. Eng. Technol., vol. 7, no. 6, pp. 869-875, Nov. 2012 crossref(new window)

6.
M. Reyes, P. Rodriguez, S. Vazquez, A. Luna, R. Teodorescu, and J. M. Carrasco, “Enhanced Decoupled Double Synchronous Reference Frame Current Controller for Unbalanced Grid-Voltage Conditions,” IEEE Trans. Power Electron., vol. 27, no. 9, pp. 3934-3943, May 2012. crossref(new window)

7.
Van-Tung Phan and Hong-Hee Lee, “Enhanced Proportional-Resonant Current Controller for Unbalanced Stand-alone DFIG-based Wind Turbines,” J. Electr. Eng. Technol., vol. 5, no. 3, pp. 443-450, Sep. 2010. crossref(new window)

8.
Young-Do Choy, Byung-Moon Han, Jun-Young Lee and Gilsoo Jang, “Real-Time Hardware Simulator for Grid-Tied PMSG Wind Power System,” J. Electr. Eng. Technol., vol. 6, no. 3, pp. 375-383, May 2011. crossref(new window)

9.
S. W. Mohod, M. Aware, “Analysis and design of a grid connected wind generating system with VSC,” in Proceedings of 2008 IEEE Region 10 Conference, Hyderabad, India, Nov. 2008.

10.
G. P. Zhao, M. X. Han, “DC voltage design and corresponding compensation performance analysis for static var generator,” Int. J. Electr. Power & Energy Syst., vol. 43, no. 1, pp. 501-513, Dec. 2013.

11.
Y. B. Wang, J. W. Li, J. Yu, “Comprehensive analysis and design for one-cycle controlled DC side APF,” in Proceedings of IEEE Industrial Technology International Conference, Mumbai, India, Dec. 2006.

12.
S.J. Chiang, J. M. Chang, “Design and implementation of the parallelable active power filter,” in Proceedings of IEEE 30th Annual Power Electron. Specialists Conference, Charleston, SC, USA, Aug. 1999.

13.
S. Fukuda, D.S. Li, “A static synchronous compensator using hybrid multi-inverters,” in Proceedings of IEEE 35th Annual Power Electron. Specialists Conference, Aachen, Germany, June, 2004.

14.
A. Tarkiainen, R. Pollanen, M. Niemela, J. Pyrhonen, “DC-link voltage effects on properties of a shunt active filter,” in Proceedings of IEEE 35th Annual Power Electron. Specialists Conference, Aachen, Germany, June, 2004.

15.
H. Akagi, Y. Tsukamoto, A. Nabae, “Analysis and design of an active power filter using quad-series voltage source PWM converters,” IEEE Trans. on Ind. Appl., vol. 26, no. 1, pp. 93-98, Jan./Feb. 1990. crossref(new window)

16.
G. P. Zhao, J. J. Liu, “Analysis and specifications of switching frequency in parallel active power filters regarding compensation characteristics,” J. Power Electron. vol. 10, no. 6, pp. 749-761, Nov. 2010. crossref(new window)

17.
A. M. Hava, E. Demirkutlu, “Output voltage control of a four-leg inverter based three-phase UPS,” in Proceedings of 2007 European Conference on Power Electronics and Applications, Aalborg, Denmark, Sept. 2007.

18.
Young-Do Choy, Byung-Moon Han, Jun-Young Lee and Gilsoo Jang, “Real-Time Hardware Simulator for Grid-Tied PMSG Wind Power System,” J. Electr. Eng. Technol., vol. 6, no. 3, pp. 375-383, May 2011. crossref(new window)

19.
Sol-Bin Lee, Kyo-Beum Lee, Dong-Choon Lee and Jang-Mok Kim, “An Improved Control Method for a DFIG in a Wind Turbine under an Unbalanced Grid Voltage Condition,” J. Electr. Eng. Technol., vol. 5, no. 4, pp. 614-622, Dec. 2010 crossref(new window)

20.
A. Cavallini, M. Loggini, G.C. Montanari, “Comparison of approximate methods for estimate harmonic currents injected by AC/DC converters,” IEEE Trans. on Ind. Electron., vol. 41, no. 2, pp. 256-262, Apr. 1994. crossref(new window)

21.
L. Asiminoaei, F. Blaabjerg, S. Hansen, “Evaluation of harmonic detection methods for active power filter applications,” in Proceedings of IEEE 2005 Twentieth Annual Applied Power Electronics Conference and Exposition, Austin, Texaa, USA, March, 2005.

22.
S.J. Lee, H. Kim, S.K. Sul, F. Blaabjerg, “A novel control algorithm for static series compensators by use of PQR instantaneous power theory,” IEEE Trans. on Power Electron., vol. 19, no. 3, pp. 814-827, May, 2004. crossref(new window)