Effect of IPMSM d-q Axis Parameters According to Magnetic Saturation and Armature Reaction
Jang, Kibong;
  PDF(new window)
FEA was used to analyze inductance and torque of IPMSM. Torque and inductance are analyzed on the dq-axis. It was shown that Ld and Lq have harmonic components, and magnitude as well as phase of the harmonics varies according to the current values. This paper shows the relationship between these inductance harmonics and the 6th harmonic component of torque.
IPM;Harmonics;Magnetic saturation;Vector control;Inductance;Flux linkage;
 Cited by
Rahman, K.M.; Hiti, S., “Identification of machine parameters of a synchronous motor,” IEEE Transactions on Industry Applications, vol. 41, no. 2, pp. 557-565, March-April 2005 crossref(new window)

Dutta, R.; Rahman, M.F., “A Comparative Analysis of Two Test Methods of Measuring d - and q -Axes Inductances of Interior Permanent-Magnet Machine,” IEEE Transactions on Magnetics, vol. 42, no. 11, pp. 3712-3718, Nov. 2006 crossref(new window)

Yoshiaki Kano ; Kyohei Watanabe ;Takashi Kosaka ; Nobuyuki Matsui, “A new modeling approach for circuit-field-coupled time-stepping electromagnetic analysis of saturated interior permanent magnet synchronous motors,” EE. in Japan, Vol. 174, No. 1, pp. 49-58, 2011.

O.A. Mohammed; S. Liu; Z. Liu, “Physical Modeling of PM Synchronous Motors for Integrated Coupling With Machine Drives,” IEEE Transactions on Magnetics, vol. 41, no. 5, pp. 1628-1631, Nov. 2005 crossref(new window)

Thomas Herold; David Franck; Enno Lange; Kay Hameyer, “Extension of a D-Q Model of a Permanent Magnet Excited Synchronous Machine by Including Saturation, Cross-Coupling and Slotting Effects,” IEEE International Electric Machines & Drive conference (IEMDC), 2011