JOURNAL BROWSE
Search
Advanced SearchSearch Tips
Recognition and Classification of Power Quality Disturbances on the basis of Pattern Linguistic Values
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
 Title & Authors
Recognition and Classification of Power Quality Disturbances on the basis of Pattern Linguistic Values
Liu, XiaoSheng; Liu, Bo; Xu, DianGuo;
  PDF(new window)
 Abstract
This paper presents a new recognition and classification method for power quality (PQ) disturbances on the basis of pattern linguistic values. This method solves the difficulty of recognizing disturbances rapidly and accurately by using fuzzy logic. This method uses classification disturbance patterns to define the linguistic values of fuzzy input variables and used the input variables of corresponding disturbance pattern to set membership functions. This method also sets the fuzzy rules by analyzing the distribution regularities of the input variable values. One characteristic of this method is that the linguistic values of fuzzy input variables and the setting of membership functions are not only related to the input variables but also to the character of classification disturbance and the classification results. Furthermore, the number of fuzzy rules is equal to the number of disturbance patterns. By using this method for disturbance classification, the membership function and design of fuzzy rules are directly related to the objective of classification, thus effectively reducing the complexity of the design process and yielding accurate classification results. The classification results of the simulation and measured data verify the feasibility and effectiveness of this method.
 Keywords
Power quality;Disturbances classification;Fuzzy logic;S-transform;
 Language
English
 Cited by
 References
1.
F. Z. Zhao, R. G. Yang, “Voltage sag disturbance detection based on short-time Fourier transform,” Proceedings of the CSEE, vol. 27, no. 10, pp. 28-34, 109, Apr. 2007.

2.
T. X. Zhu, S. K. Tso, and K. L. Lo, “Wavelet-based fuzzy reasoning approach to PQ disturbance recognition,” IEEE Trans. Power Deliv., vol. 19, no. 4, pp. 1928-1935, Oct. 2004. crossref(new window)

3.
R. G. Stockwell, L. Mansinha, and R. P. Lowe, “Localization of the complex spectrum: the S-transform,” IEEE Transactions on Signal Processing, vol. 44, no. 4, pp. 998-1001, Apr. 1996. crossref(new window)

4.
M. S. Manikandan, S. R. Samantaray, I. Kamwa, et.al, “Detection and classification of power quality disturbances using sparse signal decomposition on hybrid dictionaries,” IEEE Transactions on Instrumentation and Measurement, vol. 64, no. 1, pp. 594-605, Jan. 2015.

5.
S. Kalyani and K.S. Swarup, “Classification and assessment of power system security using multiclass SVM,” IEEE Trans. Syst. Man and Cybernetics Part C-Applications and Reviews, vol. 41, no. 5, pp. 753-758, Sep. 2011. crossref(new window)

6.
K. Manimala, K. Selvi, and R. Ahila, “Optimization techniques for improving power quality data mining using wavelet packet based support vector machine,” Neurocomputing, vol. 77, no. 1, pp. 36-47, Feb. 2012. crossref(new window)

7.
H. Eristi and Y. Demir, “Automatic classification of power quality events and disturbances using wavelet transform and support vector machines,” IET Gener. Transm. Distrib., vol. 6, no. 10, pp. 986-976, 2012. crossref(new window)

8.
N. Thai and L. Yuan, “Power quality disturbance classification utilizing S-transform and binary feature matrix method,” Electric Power Systems Research, vol. 79, pp. 569-575, Apr. 2012.

9.
T. K. Abdel-Galil, E. F. El-saadany, and A. M. Youssef, et.al, “Disturbance classification using hidden Markov models and vector quantization,” IEEE Trans. Power Deliv., vol. 20, no. 3, pp. 2129-2135, Jul. 2005. crossref(new window)

10.
S. Mishra, C. N. Bhende, and B. K. Panigrahi, “Detection and classification of power quality disturbances using S-transform and probabilistic neural network,” IEEE Trans. Power Deliv., vol. 23, no. 1, pp. 280-287, Jan. 2008. crossref(new window)

11.
O. Mário, V. C. Denis, and D. F. Odilon, et.al, “Power quality analysis applying a hybrid methodology with wavelet transforms and neural networks,” Electrical Power and Energy Systems, vol. 31, no.5, pp. 206-212, Jun. 2009. crossref(new window)

12.
K. Raj, S. Bhim, and T. S. Dilip, “Recognition of single-stage and multiple power quality events using Hilbert-Huang transform and probabilistic neural network,” Electrical Power and Energy Systems, vol. 43, no. 6, pp. 607-619, Apr. 2015.

13.
A. N. Chirag and K. Prasanta, “Power quality disturbance classification employing S-transform and three-module artificial neural network,” Int. Trans. Electr. Energ. Syst. vol. 24, no. 9, pp. 1301-1322, Sep. 2014. crossref(new window)

14.
B.K. Panigrahi and V.R. Pandi, “Optimal feature selection for classification of power quality disturbances using wavelet packet-based fuzzy k-nearset neighbour algorithm,” IET Gener. Transm. Distrib., vol. 3, no. 3, pp. 296-306, Mar. 2009. crossref(new window)

15.
S. R. Samantaray, “Decision tree-initialised fuzzy rule-based approach for power quality events classification,” IET Gener. Transm. Distrib., vol. 4, no. 4, pp. 538-551, Apr. 2010. crossref(new window)

16.
A. A. Abdelsalam, A. A. Eldesouky, and A. A. Sallam, “Classification of power system disturbances using linear Kalman filter and fuzzy-expert system,” Int. Jour. Elec. Power, vol. 43, no. 1, pp. 688-695, Dec. 2012. crossref(new window)

17.
A. Rodriguez, J. A. Aguado, and F. Martin, “Rule-based classification of power quality disturbances using S-transform,” Electric Power Systems Research, vol. 86, pp. 113-121, May 2012. crossref(new window)

18.
D. Granados-Lieberman, R.J. Romero-Troncoso, and R.A. Osornio-Rios, et.al, “Techniques and methodologies for power quality analysis and disturbances classification in power systems: a review,” IET Gener. Transm. Distrib., vol. 5, no. 4, pp. 519-529, Apr. 2011. crossref(new window)

19.
K. Rajiv and G. Rashmi, “Fuzzy lattice based technique for classification of power quality disturbances,” Eur Trans. Electr. Power, vol. 22, no. 8, pp. 1053-1064, Nov. 2012. crossref(new window)

20.
K. S. Yap, C. P. Lim, and M. T. Au, “Improved GART neural network model for pattern classification and rule extraction with application to power systems,” IEEE Trans. Neural Networ., vol.22, no.12, pp. 2310-2323, Dec. 2011. crossref(new window)

21.
S. K. Meher and A. K. Pradhan, “Fuzzy classifiers for power quality events analysis,” Electr. Pow. Syst. Res., vol. 80, no. 1, pp. 71-76, Jan. 2010. crossref(new window)

22.
H.S. Behera, P.K. Dashb, and B. Biswal, “Power quality time series data mining using S-transform and fuzzy expert system,” Appl. Soft Comput., vol. 10, no. 3, pp . 945-955, Jun. 2010. crossref(new window)

23.
S. A. Deokar, L. M. Waghmare, “Integrated DWT-FFT approach for detection and classification of power quality disturbances,” Electrical Power and Energy Systems, vol. 61, pp. 594-605, Oct. 2014. crossref(new window)

24.
M. G. Ameen, E. Nesimi, L. S. Wen, “Automatic classification and characterization of power quality events,” IEEE Trans. Power Deliv., vol. 23, no. 4, pp. 2417-2425, Oct. 2008. crossref(new window)

25.
M. Uyar, S. Yildirim, M. T. Gencoglu, “An expert system based on s-transform and neural network for automatic classification of power quality disturbances,” Expert Syst. Appl., vol. 36, no. 3, pp. 5962-5975, Apr. 2009. crossref(new window)