JOURNAL BROWSE
Search
Advanced SearchSearch Tips
Observer-Based FL-SMC Active Damping for Back-to-Back PWM Converter with LCL Grid Filter
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
 Title & Authors
Observer-Based FL-SMC Active Damping for Back-to-Back PWM Converter with LCL Grid Filter
Gwon, Jin-Su; Lee, Hansoo; Kim, Sungshin;
  PDF(new window)
 Abstract
This paper proposes an active damping control method for a grid-side converter that has an LCL grid filter in the back-to-back converter. To remove the resonant frequency components produced by the LCL filter, it is necessary to measure the grid current. To do this, sensors must be added. However, it is not necessary to add sensors because the grid current is estimated by designing a suboptimal observer. In order to remove the nonlinearity and to gain fast response of control, both feedback linearization and sliding mode control are applied. The proposed method is verified through a simulation.
 Keywords
PWM converters;FL-SMC control;Suboptimal observer;Kalman filter;Total harmonic distortion;Power quality;
 Language
English
 Cited by
 References
1.
II. J. Gabe, V. F. Montagner, and H. Pinheiro, “Design and implementation of a robust current controller for VSI connected to the grid through an LCL filter,” IEEE Trans. Power Electron., vol. 24, no. 6, pp. 1444–1452, 2009. crossref(new window)

2.
Y. Tang, P. C. Loh, P. Wang, F. H. Choo, F. Gao, and F. Blaabjerg, “Generalized design of high performance shunt active power filter with output LCL filter,” IEEE Trans. Ind. Electron., vol. 59, no. 3, pp. 1443–1452, 2012. crossref(new window)

3.
L. Xiao, Y. Lei, Z. Wang, and X. Zheng, “Optimisation of LCL filter based on closed-loop total harmonic distortion calculation model of the grid-connected inverter,” IET Power Electron., vol. 8, no. 6, pp. 860–868, 2015. crossref(new window)

4.
M. Liserre, F. Blaabjerg, and R. Teodorescu, “Grid impedance estimation via excitation of LCL-filter resonance,” IEEE Trans. Ind. Appl., vol. 43, no. 5, pp. 1401–1407, 2007. crossref(new window)

5.
W. Wu, Y. He, T. Tang, and F. Blaabjerg, “A new design method for the passive damped LCL and LLCL filter-based single-phase grid-tied inverter,” IEEE Trans. Ind. Electron., vol. 60, no. 10, pp. 4339–4350, 2013. crossref(new window)

6.
G.-B. Koo, J.-B. Park, and Y.-H. Joo, “Observer-based sampled-data controller of linear system for the wave energy converter,” Int. J. Fuzzy Log. Intell. Syst., vol. 11, no. 4, pp. 275–279, 2011. crossref(new window)

7.
D. Fr?nken, K. Meerk?tter, and J. Wa?muth, “Observer-based feedback linearization of dynamic loudspeakers with AC amplifiers,” IEEE Trans. Speech Audio Process., vol. 13, no. 2, pp. 233–242, 2005. crossref(new window)

8.
M. Liserre, F. Blaabjerg, and S. Hansen, “Design and control of an LCL-filter-based three-phase active rectifier,” IEEE Trans. Ind. Appl., vol. 41, no. 5, pp. 1281–1291, 2005. crossref(new window)

9.
G. I.With, O. Lcl, Z. Zou, S. Member, Z.Wang, M. Cheng, and S. Member, "Modeling , Analysis , and Design of Multifunction," vol. 29, no. 7, pp. 3830-3839, 2014. crossref(new window)

10.
L. Peng, Q. Liu, Y. Kang, S. Tang, D. Wu, and Y. Qi, “A Novel Design and Optimization Method of LCL Filter for Shunt Active Power Filter,” IEEE Trans. Ind. Electron., vol. 61, no. 8, pp. 4000–4010, 2014.

11.
J. Arif, S. Ray, and B. Chaudhuri, “Multivariable selftuning feedback linearization controller for power oscillation damping,” IEEE Trans. Control Syst. Technol., vol. 22, no. 4, pp. 1519–1526, 2014. crossref(new window)

12.
T. S. T. Shaocheng, C. T. C. Tianyou, and S. C. S. Cheng, “Adaptive fuzzy sliding mode control for nonlinear systems,” Proc. IEEE 5th Int. Fuzzy Syst., vol. 1, no. 1, pp. 12–18, 1996.

13.
S.-H. Yu, C.-H. Hyun, and M.-N. Park, “Backstepping Control and Synchronization for 4-D Lorenz-Stenflo Chaotic System with Single Input,” Int. J. Fuzzy Log. Intell. Syst., vol. 11, no. 3, pp. 143–148, 2011. crossref(new window)

14.
S.-H. Yu, C.-H. Hyun, and M.-G. Park, “Control and Synchronization of New Hyperchaotic System using Active Backstepping Design,” Int. J. Fuzzy Log. Intell. Syst., vol. 11, no. 2, pp. 77–83, 2011. crossref(new window)