RESEARCH PAPERS : A DEVELOPMENT OF A NOVEL THERMAL DESORPTION TECHNIQUE FOR MEASUREMENT OF VOCS IN AMBIENT AIR
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
  • Journal title : Environmental Engineering Research
  • Volume 7, Issue 3,  2002, pp.177-184
  • Publisher : Korean Society of Environmental Engineering
  • DOI : 10.4491/eer.2002.7.3.177
 Title & Authors
RESEARCH PAPERS : A DEVELOPMENT OF A NOVEL THERMAL DESORPTION TECHNIQUE FOR MEASUREMENT OF VOCS IN AMBIENT AIR
Lee,Gang-Ung; Kim,Jo-Cheon; Song,Hui-Nam; Kim,Jong-Hwan; Han,Jin-Seok; Sin,Jin-Ho;
  PDF(new window)
 Keywords
nafion dryer;peltier trap;preconcentration;thermal desorption;VOC;
 Language
English
 Cited by
 References
1.
Choi, H. J., "Preional Air Quality Management Polices and Prospects in Korea," Proceedings of 30th Meeting of KOSAE, pp. 41 -43 (2000).

2.
Rafson, J. H., Odor and VOC Control Handbook, Mcgraw-Hill, New York, (1998).

3.
Ministry of Environment, Environmental White Paper, Chapter 3 (2001).

4.
Paek, S. O., "Sampking and Analytical Methods for the Determination of Volatitle Organic Compounds in Ambient Air," J KAPRA, 12(1),1-13 (1996),

5.
Kim, M. G., Park, C. O., Kwon, Y. J., Lee, Y. K., and Lee, D. W., "Variations of Concentration Levels of Volatitle Organic Compounds in the Indoor Air due to Floor Waxing," KOSAE's Regular Conference, 11, 253 - 254 (1998).

6.
Heo, G, S. and Kim, B. J., "Development of VOC CRM and INterlaboratory comparison of VOC Analysis between Domestic Analytical Lads(I)," J. KAPRA , 13, 221 - 229 (1998).

7.
McClenny, W. A., Pleil, J. D., Evans, G. F., Oliver, K. D., Holdrene, M. W., and Winberry, W. T., "Canister-Based Method for Monitoring Toxic VOCs in Ambient Air," Air & Waste Management Association, 41, 1308-1318 (1991). crossref(new window)

8.
Sin, D. W., Wong, Y. C., Sham, W. C., and Wang, D., "Development of an analytical technique and stability technique and stability evaluation of 143 C3-C12 volatile organic compounds in Summa canisters by gas chromatography-mass spectrometry," The Analyst, 126(3), 310-321 (2001). crossref(new window)

9.
Riggin, R. M. and Markle, R. A., Comparison of Solid Adsorbent Sampling Techniques for Volatile Organic Compounds in Ambient Air, EPA/600/S4-85/077 (1986).

10.
Pollack, A. J. and Holdren, M. W., "Multiadsorbent Preconcentration and Gas Chromatographic Analysis of Air Toxics with an Automated Collection/Analytical System," Air & Waste Management Association, 41, 1213 - 1217 (1991). crossref(new window)

11.
Kim, J-C, "Factors controlling natural VOC emissions in a southeastern US pine forest," Atmos. Environ., 35, 3279 - 3292 (2001). crossref(new window)

12.
Woolfenden, E. A., Broadway, G. M., Higham, P., and Seeley, I., Alternative on-line and sorbent tube-based sampling procedures for 24-hr air pollution profiling, Perkin Elmer Inc. (1994).

13.
Shepson, P. B., Kseindienst, T. E., and McElhoe H. B., "A Cryogenic Trap/Porous Polymer Sampling Techniques for the Quantitative Determination of Ambient Volatile Organic Compound Concentrations," Atmos. Environ., 21, 579-587 (1987). crossref(new window)

14.
Namiesnik, J., Torres, L., Kozlowski, E., and Mathieu, J., "Evaluation of the suitability of selected porous polymers for preconcentration of volatile organic compounds," J. Chromatography, 208, 239-252 (1981).

15.
Senum, G. I., "Theoretical Collection Efficiencies of Adsorbent Samplers," Environ. Sci. Technol., 15, 1073-1075 (1981). crossref(new window)

16.
Harris, J. C., Miseo, E. V., and Piecewicz, J. F., Further Characterization of Sorbents for Environmental Sampling, EPA-600/5782-052 (1982).

17.
MacLeod, G. and Ames, J. M., Comparative Assessment of the Artifact Background on Thermal Desorption of Tenax-GC and Tenax-TA, Elsevier Sci. Publishers B.V. (1986).

18.
Rothweiler, H., Wager, P. A., and Schsatter C., "Comparison of Tenax-TA and Carbotrap for Sampling and Analysis of Volatile Organic Compounds in Air," Atmos. Environ.. 25B, 231-235 (1991).

19.
Cao, X-L and Hewitt, C. N., "Thermal Desorption Efficiences for Different Adsorbate/Adsorbent Systems typically used in Air Monitoring Programs," Chemosphere, 27, 695-705 (1993). crossref(new window)

20.
Kim, K-H, Kim, J-C, Lee, G., Heo, G. S., and Lee., B-K, "Interlaboratory Study of Sampling and Analysis Techniques for Ambient VOCs under Field Conditions," J. KOSAE, 16, 685-691 (2000).

21.
Walling, J. F., Berkley, F. E., Swanson, D. H., and Toth, F. J., Sampling Air for Gaseous Organic Chemicals Using Solid Adsorbents, Application to Tenax. EPA600/S4-82-059 (1982).

22.
Bertman, S. B., Martin, P, B., and Roberts, J. M., "Automated Cryogenic Trapping Technique for Capillary GC Analysis of Atmospheric Trace Compounds Requiring No Expendable Cryobens: Application to the Measurement of Organic Nitrates," Anal. Chem., 65, 2944-2946 (1993). crossref(new window)

23.
Paek, S. O., "Sampling and Analytical Methods for the Determination of Volatile Organic Compounds in Ambient Air," J.KAPRA, 12(1), 1-13 (1996).