Identification and Determination of Oil Pollutants Based on 3-D Fluorescence Spectrum Combined with Self-weighted Alternating Trilinear Decomposition Algorithm
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
 Title & Authors
Identification and Determination of Oil Pollutants Based on 3-D Fluorescence Spectrum Combined with Self-weighted Alternating Trilinear Decomposition Algorithm
Cheng, Pengfei; Wang, Yutian; Chen, Zhikun; Yang, Zhe;
  PDF(new window)
 Abstract
Oil pollution seriously endangers the biological environment and human health. Due to the diversity of oils and the complexity of oil composition, it is of great significance to identify the oil contaminants. The 3-D fluorescence spectrum combined with a second order correction algorithm was adopted to measure an oil mixture with overlapped fluorescence spectra. The self-weighted alternating trilinear decomposition (SWATLD) is a kind of second order correction, which has developed rapidly in recent years. Micellar solutions of #0 diesel, #93 gasoline and ordinary kerosene in different concentrations were made up. The 3-D fluorescence spectra of the mixed oil solutions were measured by a FLS920 fluorescence spectrometer. The SWATLD algorithm was applied to decompose the spectrum data. The predict concentration and recovery rate obtained by the experiment show that the SWATLD algorithm has advantages of insensitivity to component number and high resolution for mixed oils.
 Keywords
SWATLD;3-D fluorescence spectrum;Oil mixture;Component number;
 Language
Korean
 Cited by
 References
1.
M. A. Cohen, “Water pollution from oil spills,” Encyclopedia of Energy, Natural Resource, and Environmental Economics 3, 121-126 (2013).

2.
R. H. Peiris, M. Jaklewicz, and H. Budman, “Assessing the role of feed water constituents in irreversible membrane fouling of pilot-scale ultrafiltration drinking water treatment systems,” Water Res. 47, 3364-3374 (2013). crossref(new window)

3.
M. Insausti and B. S. Fernández Band, “Single excitation-emission fluorescence spectrum (EEF) for determination of cetane improver in diesel fuel,” Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy 140, 416-420 (2015). crossref(new window)

4.
J. R. Choi, K. Kim, and D. Kim, “In situ fluorescence optical detection using a Digital Micromirror Device (DMD) for 3D cell-based assays,” J. Opt. Soc. Korea 16, 42-46 (2012). crossref(new window)

5.
J. Lee, C. G. Pack, S. Y. Kim, and S. W. Kim, “Diffusion coefficients of CdSe/CdS quantum rods in water measured using polarized fluorescence correlation spectroscopy,” J. Opt. Soc. Korea 18, 598-604 (2014). crossref(new window)

6.
D. Patra, “Distinguishing motor oils at higher concentration range by evaluating total fluorescence quantum yield as a novel sensing tool,” Sens. Actuators B: Chemical 129, 632-638 (2008). crossref(new window)

7.
R. J. Kavanagh, K. B. Burnison, and R. A. Frank, "Detecting oil sands process-affected waters in the Alberta oil sands region using synchronous fluorescence spectroscopy," Chemosphere 76, 7 (2009).

8.
M. Fernandez, S. Clavijo, R. Forteza, and V. Cerda, “Determination of polycyclic aromatic hydrocarbons using lab on valve dispersive liquid-liquid microextraction coupled to high performance chromatography,” Talanta 138, 190-195 (2015). crossref(new window)

9.
M. Gao, H. Wang, and M. Ma, “Optimization of a phase separation based magnetic-stirring salt-induced liquid-liquid microextraction method for determination of fluoroquinolones in food,” Food Chem. 175, 181-188 (2015). crossref(new window)

10.
M. Suranova, J. Semanova, and B. Sklarsova, “Application of accelerated solvent extraction for simultaneous isolation and pre-cleaning up procedure during determination of polycyclic aromatic hydrocarbons in smoked meat products,” Food Anal. Method 8, 1014-1020 (2015). crossref(new window)

11.
L. Ferey and N. Delaunay, “Capillary and microchip electrophoretic analysis of polycyclic aromatic hydrocarbons,” Anal. Bioanal. Chem. 407, 2727-2747 (2015). crossref(new window)

12.
M. Kalwa, S. P. Quinaia, A. L. Pletsch, Y. R. Torres, and D. Finger, “Polycyclic aromatic hydrocarbons in surface sediments of Binacional Itaipu Lake, Brazil: characteristics, sources and toxicity evaluation,” Env. Earth Sci. 72, 4473-4481 (2014). crossref(new window)

13.
Y. Ma, C. Q. Cai, H. M. Yang, L. Luo, and X. M. Chen, “The amplified resonance light scattering signal detection of DNA hybridization using polycyclic aromatic hydrocarbons as a probe,” Spectrosc. Lett. 47, 184-191 (2014). crossref(new window)

14.
C. Liaud, T. Dintzer, V. Tschamber, G. Trouve, and C. S. Le, “Particle-bound PAHs quantification using a 3-stages cascade impactor in French indoor environments,” Env. Pollut. 195, 64-72 (2014). crossref(new window)

15.
A. Smolinski, P. Kuna-Gwozdziewicz, M. J. Laczny, and A. Bak, “Study of the polycyclic aromatic hydrocarbons content in gas released from burning mine waste dump,” Acta Chromatographia 27, 239-254 (2015). crossref(new window)

16.
Z. K. Chen, Y. Wang, F. B. Wang, Y. T. Wang, and Y. Zhou, “Excitation-emission matrix spectroscopy and parallel factor analysis for micro-content petroleum pollutant,” Spectrosc. Spect. Anal. 34, 2561-2567 (2014).

17.
B. Q. Zhu, S. A. Pennell, and D. K. Ryan, “Characterizing the interaction between uranyl ion and soil fulvic acid using parallel factor analysis and a two-site fluorescence quenching model,” Microchem. J. 115, 51-57 (2014). crossref(new window)

18.
H. Parastar and N. Akvan, “Multivariate curve resolution based chromatographic peak alignment combined with parallel factor analysis to exploit second-order advantage in complex chromatographic measurements,” Anal. Chim. Acta 816, 18-27 (2014). crossref(new window)

19.
L. J. Li and S. X. Du, “The three-dimensional fluorescence spectrometric detection of mycotoxin based on parallel factor analysis,” Chin. J. Anal. Chem. 31, 40-43 (2012).

20.
S. R. Zhang, H. L. Wu, and R. Q. Yu, “A study on the differential strategy of some iterative trilinear decomposition algorithms: PARAFAC-ALS, ATLD, SWATLD, and APTLD,” J. Chemometr. 29, 179-191 (2015). crossref(new window)

21.
Y. Li, H. L. Wu, and X. D. Qing, “A novel method to estimate the chemical rank of three-way data for second-order calibration,” Chemometr. Intell. Lab. Syst. 127, 177-184 (2013). crossref(new window)

22.
L. Yang, D. L. Liu, and Y. J. Wei, “Determination of Osthole in Cnidii Fructus and human plasma using excitation-emission matrix fluorescence with the aid of second-order calibration methods,” Chin. J. Anal. Chem. 34, 22-26 (2015).

23.
L. Q. Hu, C. L. Yin, Y. H. Du, and Z. P. Zeng, "Simultaneous and direct determination of Vancomycin and Cephalexin in human plasma by using HPLC-DAD coupled with second-order calibration algorithms," J. Anal. Method. Chem. 2012, 256963 (2012).

24.
J. Zhang, Z. J. Wang, S. R. Zhu, and X. M. Meng, “Determination of sulfonamides in synthetic samples and pharmaceutical tablets using HPLC-DAD combined with SWATLD algorithm,” Information Technology Applications in Industry 263, 2117-2121 (2013).

25.
R. Bro, "Multi-way analysis in the food industry, models, algorithms, and applications," Ph. D. Thesis, University of Amsterdam (1998), pp. 110-121.

26.
J. A. Ocana, F. J. Barragan, and M. Callejon, “Spectro-fluorimetric and micelle-enhanced spectrofluorimetric determination of gatifloxacin in human urine and serum,” J. Pharmaceut. Biomed. Anal. 37, 327-332 (2005). crossref(new window)

27.
J. L. Manzoori and M. Amjadi, “Spectrofluorimetric and micelle-enhanced spectrofluorimetric methods for the determination of gemfibrozil in pharmaceutical preparations,” J. Pharmaceut. Biomed. Anal. 31, 507-513 (2003). crossref(new window)