Demagnetization Detection for IPM-type BLDCMs According to Irreversible Demagnetization Patterns and Pole-Slot Coefficients
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
  • Journal title : Journal of Power Electronics
  • Volume 16, Issue 1,  2016, pp.48-56
  • Publisher : The Korean Institute of Power Electronics
  • DOI : 10.6113/JPE.2016.16.1.48
 Title & Authors
Demagnetization Detection for IPM-type BLDCMs According to Irreversible Demagnetization Patterns and Pole-Slot Coefficients
Kang, Dong-Hyeok; Kim, Hyung-Kyu; Park, Jun-Kyu; Hyun, Seung-Ho; Hur, Jin;
  PDF(new window)
 Abstract
This paper proposes a method for detecting irreversible demagnetization using the harmonic analysis of back electromotive force (BEMF) in interior permanent magnet-type brushless DC motors. First, demagnetization patterns, such as equality, inequality, and weighted demagnetizations, are defined and classified by considering the possibility of demagnetization resulting from motor operating characteristics. Second, an available diagnostic model for the harmonic analysis of BEMFs is defined according to pole-slot coefficients because the characteristics of BEMFs under demagnetization conditions are affected by the combination of poles and slots. Third, BEMFs and their harmonic components under normal and demagnetization conditions are analyzed through simulation and experiment to verify the proposed demagnetization detection technique.
 Keywords
Brushless DC motors;Demagnetization;Demagnetization patterns;Fault diagnosis;Permanent magnet motors;Pole- slot coefficient;
 Language
English
 Cited by
 References
1.
D. J. McFarland and T. M. Jahns, “Investigation of the rotor demagnetization characteristics of interior PM synchronous machines during fault conditions,” IEEE. Trans. Ind. Applicat., Vol. 50, No. 4, pp. 2768-2775, Jul./Aug. 2014. crossref(new window)

2.
A. Sarikhani and O. A. Mohammed, “Inter-turn fault detection in PM synchronous machines by physics-based back electromotive force estimation,” IEEE. Trans. Ind. Electron., Vol. 60, No. 8, pp. 3472-3484, Aug. 2013. crossref(new window)

3.
S. Rajagopalan, J. M. Aller, J. A. Restrepo, T. G. Habetler, and R. G. Harley, “Analytic-wavelet-ridge-based detection of dynamic eccentricity in brushless direct current (BLDC)motors functioning under dynamic operating conditions,” IEEE. Trans. Ind. Electron., Vol. 54, No. 3, pp. 1410-1419, Jun. 2007. crossref(new window)

4.
J. Urresty, J.-R. Riba Ruiz, M. Delgado, and L. Romeral, “Detection of demagnetization faults in surface-mounted permanent magnet synchronous motors by means of the zero-sequence voltage component,” IEEE. Trans. Energy Convers., Vol. 27, No. 1, pp. 42-51, Mar. 2012. crossref(new window)

5.
D. Torregrossa, A. Khoobroo, and B. Fahimi, “Prediction of acoustic noise and torque pulsation in PM synchronous machine with static eccentricity and partial demagnetization using field reconstruction method,” IEEE Trans. Ind. Electron., Vol. 59, No. 2, pp. 934-944, Feb. 2012. crossref(new window)

6.
J. M. Hong, S. U. Park, D. S. Hyun, T. J. Kang, S. B. Lee, and C. Kral, “Detection and classification of rotor demagnetization and eccentricity faults for PM synchronous motors,” IEEE. Trans. Ind. Applicat., Vol. 48, No. 3, pp. 923-932, May/Jun. 2012. crossref(new window)

7.
P. Zhou, D. Lin, Y. Xiao, N. Lambert, and M. A. Rahman, “Temperature-dependent demagnetization model of permanent magnets for finite element analysis,” IEEE. Trans. Magn., Vol. 48, No.2, pp. 1031-1034, Feb. 2012. crossref(new window)

8.
T. Hosoi, H. Watanabe, K. Shima, T. Fukami, R. Hanaoka, and S. Takata, “Demagnetization analysis of additional permanent magnets in salient-pole synchronous machines with damper bars under sudden short circuits,” IEEE. Trans. Ind. Electron., Vol. 59, No. 6, pp. 2448-2456, Jun. 2012. crossref(new window)

9.
Y. S. Lee, K. T. Kim, and J. Hur, “Finite-element analysis of the demagnetization of IPM-type BLDC motor with stator turn fault,” IEEE. Trans. Magn., Vol. 50, No. 2, Feb. 2014.

10.
A. G. Espinosa, J. A. Rosero, J. Cusido, L. Romeral, and J. A. Ortega, “Fault detection by means of Hilbert-Huang transform of the stator current in a PMSM with demagnetization,” IEEE. Trans. Energy Convers., Vol. 25, No. 2, pp. 312-318, Jun. 2010. crossref(new window)

11.
K. C. Kim, K. S. Kim, H. J. Kim, and J. Lee, “Demagnetization analysis of permanent magnets according to rotor types of interior permanent magnet synchronous motor,” IEEE. Trans. Magn., Vol. 45, No. 6, pp. 2799-2802, Jun. 2009. crossref(new window)

12.
L. Silong, L. Yingjie, and B. Sarlioglu, “Partial Irreversible Demagnetization assessment of flux-switching permanent magnet machine using ferrite permanent magnet material,” IEEE. Trans. Magn., Vol. 51, No. 7, Feb. 2015. crossref(new window)

13.
V. I. Patel, J. Wang, and S. S. Nair, “Demagnetization assessment of fractional-slot and distributed wound 6-phase permanent magnet machines,” IEEE. Trans. Magn., Vol. 51, No. 6, Dec. 2014.

14.
D. H. Kang, J. K. Park, S. H. Hyun, and J. Hur, "BEMF characteristic analysis of IPM type motor according to demagnetization pattern of permanent magnet," in proc. International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia), pp. 714-721, 2015.

15.
J. A. Farooq, A. Djerdir, and A. Miraoui, “Analytical modeling approach to detect magnet defects in permanentmagnet brushless motors,” IEEE. Trans. Magn., Vol. 44, No. 12, pp. 4599-4604, Dec. 2008. crossref(new window)

16.
S. Rajagopalan, W. Roux, T. G. Habeltler, and R. G. Harley, “Dynamic eccentricity and demagnetization rotor magnet detection in trapezoidal flux (Brushless DC)motors operating under different load conditions,” IEEE. Trans. Power Electron., Vol. 22, No. 5, pp. 2061-2069, Sep. 2007. crossref(new window)