JOURNAL BROWSE
Search
Advanced SearchSearch Tips
Orthogonal versus Parallel Plating for Distal Humeral Fractures
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
  • Journal title : Clinics in Shoulder and Elbow
  • Volume 18, Issue 2,  2015, pp.105-112
  • Publisher : Korean Shoulder and Elbow Society
  • DOI : 10.5397/cise.2015.18.2.105
 Title & Authors
Orthogonal versus Parallel Plating for Distal Humeral Fractures
Moon, Jun-Gyu; Lee, Ji-Ho;
  PDF(new window)
 Abstract
In orthopedic trauma surgery, treatment of intraarticular distal humerus fractures is a challenge. With development of implants and biomechanical studies, surgical strategies with recommendations including preoperative computed tomography images, proper approaches and open reduction and internal fixation with dual plates have emerged. In addition, as an effort to provide stable fixation to permit early elbow motion, different methods of internal fixation, particularly plate configuration, have evolved. Using dual plates, either oriented parallel to each other or orthogonal, stable fixation has been achieved and satisfactory clinical outcomes have been reported. With rationales and advantages/disadvantages of each plate configuration, both techniques are selected according to surgeons' preference, and, in specific cases, one could be preferred over another. The key to successful fixation by either technique is obtaining anatomical reduction with restoration of two stable columns of the distal humerus.
 Keywords
Humerus;Humeral fractures;Fracture fixation;
 Language
English
 Cited by
 References
1.
Abzug JM, Dantuluri PK. Use of orthogonal or parallel plating techniques to treat distal humerus fractures. Hand Clin. 2010;26(3):411-21, vii. crossref(new window)

2.
Goel DP, Pike JM, Athwal GS. Open reduction and internal fixation of distal humerus fractures. Oper Tech Orthop. 2010;20(1):24-33. crossref(new window)

3.
Green A. Surgical treatment of bicolumn distal humeral fractures: relevant anatomy and classification. Instr Course Lect. 2009;58:505-7.

4.
Tejwani NC, Murthy A, Park J, McLaurin TM, Egol KA, Kummer FJ. Fixation of extra-articular distal humerus fractures using one locking plate versus two reconstruction plates: a laboratory study. J Trauma. 2009;66(3):795-9. crossref(new window)

5.
Schemitsch EH, Tencer AF, Henley MB. Biomechanical evaluation of methods of internal fixation of the distal humerus. J Orthop Trauma. 1994;8(6):468-75. crossref(new window)

6.
Schuster I, Korner J, Arzdorf M, Schwieger K, Diederichs G, Linke B. Mechanical comparison in cadaver specimens of three different 90-degree double-plate osteosyntheses for simulated C2-type distal humerus fractures with varying bone densities. J Orthop Trauma. 2008;22(2):113-20. crossref(new window)

7.
Wong AS, Baratz ME. Elbow fractures: distal humerus. J Hand Surg Am. 2009;34(1):176-90. crossref(new window)

8.
Ramsey ML. Surgical exposures for bicolumn distal humeral fractures. Instr Course Lect. 2009;58:509-14.

9.
Seigerman DA, Choung EW, Yoon RS, et al. Identification of the radial nerve during the posterior approach to the humerus: a cadaveric study. J Orthop Trauma. 2012;26(4):226-8. crossref(new window)

10.
Yildirim AO, Oken OF, Unal VS, Esmer AF, Gülçek M, Ucaner A. Avoiding iatrogenic radial nerve injury during humeral fracture surgery: a modified approach to the distal humerus. Acta Orthop Traumatol Turc. 2012;46(1):8-12. crossref(new window)

11.
McCann PA, Smith GC, Clark D, Amirfeyz R. The tricipital aponeurosis: a reliable soft tissue landmark for humeral plating. Hand Surg. 2015;20(1):53-8. crossref(new window)

12.
Jupiter JB, Neff U, Holzach P, Allgower M. Intercondylar fractures of the humerus. An operative approach. J Bone Joint Surg Am. 1985;67(2):226-39.

13.
Korner J, Diederichs G, Arzdorf M, et al. A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates. J Orthop Trauma. 2004;18(5):286-93. crossref(new window)

14.
Helfet DL, Schmeling GJ. Bicondylar intraarticular fractures of the distal humerus in adults. Clin Orthop Relat Res. 1993;(292):26-36.

15.
Henley MB, Bone LB, Parker B. Operative management of intra-articular fractures of the distal humerus. J Orthop Trauma. 1987;1(1):24-35. crossref(new window)

16.
Holdsworth BJ, Mossad MM. Fractures of the adult distal humerus. Elbow function after internal fixation. J Bone Joint Surg Br. 1990;72(3):362-5.

17.
Letsch R, Schmit-Neuerburg KP, Sturmer KM, Walz M. Intraarticular fractures of the distal humerus. Surgical treatment and results. Clin Orthop Relat Res. 1989;(241):238-44.

18.
Sanchez-Sotelo J, Torchia ME, O'Driscoll SW. Complex distal humeral fractures: internal fixation with a principle-based parallel-plate technique. J Bone Joint Surg Am. 2007;89(5):961-9. crossref(new window)

19.
O'Driscoll SW. Optimizing stability in distal humeral fracture fixation. J Shoulder Elbow Surg. 2005;14(1 Suppl S):186S-94. crossref(new window)

20.
O'Driscoll SW. Parallel plate fixation of bicolumn distal humeral fractures. Instr Course Lect. 2009;58:521-8.

21.
Schwartz A, Oka R, Odell T, Mahar A. Biomechanical comparison of two different periarticular plating systems for stabilization of complex distal humerus fractures. Clin Biomech (Bristol, Avon). 2006;21(9):950-5. crossref(new window)

22.
Got C, Shuck J, Biercevicz A, et al. Biomechanical comparison of parallel versus 90-90 plating of bicolumn distal humerus fractures with intra-articular comminution. J Hand Surg Am. 2012;37(12):2512-8. crossref(new window)

23.
Self J, Viegas SF, Buford WL Jr, Patterson RM. A comparison of double-plate fixation methods for complex distal humerus fractures. J Shoulder Elbow Surg. 1995;4(1 Pt 1):10-6. crossref(new window)

24.
Stoffel K, Cunneen S, Morgan R, Nicholls R, Stachowiak G. Comparative stability of perpendicular versus parallel doublelocking plating systems in osteoporotic comminuted distal humerus fractures. J Orthop Res. 2008;26(6):778-84. crossref(new window)

25.
Penzkofer R, Hungerer S, Wipf F, von Oldenburg G, Augat P. Anatomical plate configuration affects mechanical performance in distal humerus fractures. Clin Biomech (Bristol, Avon). 2010;25(10):972-8. crossref(new window)

26.
Sabalic S, Kodvanj J, Pavic A. Comparative study of three models of extra-articular distal humerus fracture osteosynthesis using the finite element method on an osteoporotic computational model. Injury. 2013;44 Suppl 3:S56-61. crossref(new window)

27.
Zalavras CG, Vercillo MT, Jun BJ, Otarodifard K, Itamura JM, Lee TQ. Biomechanical evaluation of parallel versus orthogonal plate fixation of intra-articular distal humerus fractures. J Shoulder Elbow Surg. 2011;20(1):12-20. crossref(new window)

28.
Caravaggi P, Laratta JL, Yoon RS, et al. Internal fixation of the distal humerus: a comprehensive biomechanical study evaluating current fixation techniques. J Orthop Trauma. 2014;28(4):222-6. crossref(new window)

29.
Arnander MW, Reeves A, MacLeod IA, Pinto TM, Khaleel A. A biomechanical comparison of plate configuration in distal humerus fractures. J Orthop Trauma. 2008;22(5):332-6. crossref(new window)

30.
Shin SJ, Sohn HS, Do NH. A clinical comparison of two different double plating methods for intraarticular distal humerus fractures. J Shoulder Elbow Surg. 2010;19(1):2-9. crossref(new window)

31.
Tian D, Jing J, Qian J, Li J. Comparison of two different doubleplate fixation methods with olecranon osteotomy for intercondylar fractures of the distal humeri of young adults. Exp Ther Med. 2013;6(1):147-51.

32.
Lee SK, Kim KJ, Park KH, Choy WS. A comparison between orthogonal and parallel plating methods for distal humerus fractures: a prospective randomized trial. Eur J Orthop Surg Traumatol. 2014;24(7):1123-31. crossref(new window)

33.
Sanchez-Sotelo J, Torchia ME, O'Driscoll SW. Complex distal humeral fractures: internal fixation with a principle-based parallel-plate technique. Surgical technique. J Bone Joint Surg Am. 2008;90 Suppl 2 Pt 1:31-46. crossref(new window)

34.
Green A. Postoperative management after open reduction and internal fixation of distal humeral fractures. Instr Course Lect. 2009;58:535-9.

35.
Kimball JP, Glowczewskie F, Wright TW. Intraosseous blood supply to the distal humerus. J Hand Surg Am. 2007;32(5):642-6. crossref(new window)