A Study on the Protective Capacity of Military Shelters in the Contact Areas
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
 Title & Authors
A Study on the Protective Capacity of Military Shelters in the Contact Areas
Park, Young Jun; Park, Sangjin; Eom, Hong Seob; Son, Kiyoung;
  PDF(new window)
 Abstract
Protection against direct projectiles has been adapted just to the main command posts in the existing protective facility standards. However, protective capacity for the shelters against direct projectiles is also required because the initial survivability as well as the operation sustainment of the shelters is critical during a couple of days from outbreak of war. In this study, the Russian artillery is used to determine the existing and future threat of the North Korean Armed Forces indirectly. And then, required protective capacity of military shelters in the contact areas is calculated along with UFC 3-340-02 and it is verified using modeling and simulation. Based on the assessed capacity, actual inspect of military facilities with contact areas on spot is performed whether military shelters have enough protection capacity against determined threats. According to the field study, it is verified that proper earth bermed shelter has enough protection capacity. The results in this study could be used how to retrofit the current shelters in the contact areas.
 Keywords
Shelters;Protective Capacity;Overburden Soil Load;Contact Area;
 Language
Korean
 Cited by
1.
M&S를 통한 지하탄약고의 격실 방폭문 내폭력 산정 연구,박영준;백종혁;손기영;

한국군사과학기술학회지, 2016. vol.19. 3, pp.302-310 crossref(new window)
2.
접적지역 RC형 방호시설 조사와 모델링을 통한 한국형 방호벽 설계안의 제시,박영준;이민수;이희만;

한국건축시공학회지, 2016. vol.16. 4, pp.341-348 crossref(new window)
1.
Suggestion on the Prototype of the Korean Barriers through the Investigation and Modeling of RC Protective Installments in Contact Areas, Journal of the Korea Institute of Building Construction, 2016, 16, 4, 341  crossref(new windwow)
 References
1.
Field Manuals 0-1 Strategy(ROK Army Headquarters, 2013).

2.
Field Manuals 9-8 Division(ROK Army Headquarters, 2009).

3.
A Study on Reestablishment of Protection Criteria in Contact Area(Defense Installations Agency, 2014).

4.
A Study on Protective Criteria for the Important Military Facilities(Ministry of National Defense, 2012).

5.
Hazardous Materials Management(Consolidated Army Logistics School, 2010).

6.
Design Guideline to Ammunition Storage(Ministry of National Defense, 2012).

7.
Modern protective structures(Yangseogak, 2012).

8.
TM 5-855-1(US Army, 1965).

9.
UFC 3-340-02(US DOD, 2008).

10.
L. Bibiana, and A. Ricardo, "Craters Produced by Underground Explosions," de Mecanica Computacional, Vol. 225, pp. 1603-1614, 2006.