 Abstract
To evaluate the safety of propane cylinder, the flame test was performed by the flame exposure scenario of propane cylinder. The cylinder which was exposed in a flame was rapidly occurred to increase the internal pressure by liquid expansion, if so it cause of physical explosion. Therefore, the cylinder which was applied with thermal pressure relief device sholud be not bursted and the propane should be discharged to outside safely. The flame average temperature that was around of cylinder is , and then it increased by discharged propane. The result of flame test, the cylinder was deformed, but it was not bursted. The regulations of flame exposure test for propane cylinder were not restricted, this paper can be applied to restrict the flame test if the cylinder is possible to expose the flame. Also, the results is expected as reference for estimation of the pressure cylinder performance.
 Keywords
propane cylinder;flame test;thermal pressure relief device;
 Language
Korean
 Cited by
 References
1.
K. P. Lee, S. M. Kwan, "Developing a Scale of Competitiveness Focusing on the Selection Attributes of Auto-Camp Ground", The Korea Academic Society of Tourism and Leisure, Vol(25), No(3), pp. 37-52, 2013.

2.
B. Y. Lee, Y. C. Jung, "A Study on the Relationship Between Auto-camping Experiences, Satisfaction and Behavioral intentions : Focused on the 4Es Theory", The Korea Academic Society of Tourism and Leisure, Vol(24), No(7), pp. 275-294, 2012.

3.
K. P. Lee, S. M. Kwan, "An Analysis of Structural Relationships between Motivation, Values, Satisfaction, and Loyalty for Auto Camping Participants", Korea Academic Society of Tourism Management, Vol(28), No(5), pp. 45-70, 2013.

4.
API RP 520 : 2003, Sizing, Selection, and Installation of Pressure-Relieving Devices in Refineries : Part 2 - Installation, American Petroleum Institute, 2003

5.
LP Gas Code of Practice 1, Bulk LPG Storage at Fixed Installations Part 1 : 2004 - Design, Installation and Operation of Vessels Located Abobe Ground, LP Gas Association, 2004

6.
Korea Gas Safety Corporation, "Facility/Technical/Inspection/Re-inspection Code for Manufacture of Safety Valves for High-pressure Gases", Republic of Korea, 2015