JOURNAL BROWSE
Search
Advanced SearchSearch Tips
A Study on the Risk of Particulate Materials Included in the Combustion Products of Building Materials
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
  • Journal title : Fire Science and Engineering
  • Volume 30, Issue 1,  2016, pp.43-48
  • Publisher : Korea Institute of Fire Science and Engineering
  • DOI : 10.7731/KIFSE.2016.30.1.043
 Title & Authors
A Study on the Risk of Particulate Materials Included in the Combustion Products of Building Materials
Kim, Nam-Kyun; Cho, Nam-Wook; Rie, Dong-Ho;
  PDF(new window)
 Abstract
In this study, the experiment to confirm the risks of particulate material was carried out as a precedent study for developing the toxicity evaluation method of combustion products including the toxicity of particulate material. In the experiment, the test result of filtering and exposing particulate material among combustion products and that of exposing combustion products including particulate material were compared and analyzed by analyzing changes in average movement stop time according to the installation of Membrane filter between the stirring box and test box through the gas toxicity test of the same specimen to filter particulate material among combustion products. As the test result, in case of installing a filter, the average movement stop time of an experimental rat increased by up to 264% in case of lumber specimen and up to 179% in case of urethane specimen. Through such result, the necessity of identifying the toxicity of particulate material and carrying out quantitative toxicity test for particulate material was confirmed.
 Keywords
Particulate materials;Combustion gas;Gas toxicity;Building materials;
 Language
Korean
 Cited by
1.
필로티 공간의 화재 시 재실자의 위험성에 관한 연구,최승복;최두찬;최돈묵;

한국화재소방학회논문지, 2016. vol.30. 5, pp.144-150 crossref(new window)
2.
목재 기반 소재의 연소생성물 노출 실험을 통한 독성요인 분석,김남균;박정호;조남욱;

한국화재소방학회논문지, 2016. vol.30. 6, pp.57-63 crossref(new window)
 References
1.
KS F 2271 : 2006, "Fire Retardant Testing Method of Interior Finishes and Structures" (2006).

2.
H. R. Kim, Y. T. Kim, Y. J. Park and H. P. Lee, "A Study on the Toxicity of Wall Papers", Proceedings of 2009 Autumn Annual Conference, Korean Institute of Fire Science and Engineering, pp. 492-497 (2009).

3.
Y. K. Park, D. I. Kim and S. H. Hyun, "The Combustion Gases Toxicity Evaluation of Plastics Material by Colorimetric Gas Detector Tubes", Fire Science and Engineering, Vol. 16, No. 4, pp. 77-84 (2002).

4.
Y. K. Park, "A Study on Combustible Gases Toxicity Evaluation of Polymeric Materials", Fire Science and Engineering, Vol. 15, No. 3, pp. 7-13 (2001).

5.
N. W. Cho, J. C. Lee, B. J. Lee, J. B. Choi and D. H. Rie, "A Comparative Study on Toxic Gas Index by BS6853 and Gas Hazardous Test", Proceedings of 2010 Spring Annual Conference, Korean Institute of Fire Science & Engineering, pp. 155-159 (2011).

6.
S. S. Kim, N. W. Cho and D. H. Rie, "A Research for Assesment Fire Toxic Gas of Construction Material Using FT-IR and FED", Fire Science and Engineering, Vol. 25, No. 6, pp. 27-31 (2011).

7.
S. S. Kim, N. W. Cho and D. H. Rie, "A Research of Risk Assesment for Urethane Fire Based on Fire Toxicity", Fire Science and Engineering, Vol. 29, No. 2, pp. 73-78 (2015).

8.
D. H. Lee and Y. K. Kong, "A Study on Combustion Gas Toxicity of Polymeric Materials Using FTIR Gas Analysis", Journal of Korean Society of Hazard Mitigation, Vol. 5, No. 4, pp. 79-84 (2005).

9.
N. W. Cho, J. C. Lee and D. H. Rie, "A Comparative Study on Toxic Gas Index and Stop Time of Mouse Activity", Fire Science and Engineering, Vol. 25, No. 4, pp. 35-41 (2011).

10.
Republic of Korea, Ministry of Land, Transport and Maritime Affairs Act 2011-39, "Fire Retardant Performance Standard of Interior Finishes" (2011).

11.
ISO 19702 : 2006, "Toxicity Testing of Fire Effluents - Guidance for Analysis of Gases and Vapours in Fire Effluents Using FT-IR Gas Analysis" (2006).

12.
ISO TR 13344 : 2004, "Estimation of the Lethal Toxic Potency of Fire Effluents" (2004).

13.
G. E. Hartzell, D. N. Priest and W. G. Switzer, "Modeling of Toxicological Effects of Fire Gases: Ii. Mathematical Modeling of Intoxication of Rats by Carbon Monoxide and Hydrogen Cyanide", Journal of Fire Sciences, Vol. 3, No. 2, pp. 115-128 (1985). crossref(new window)

14.
US army medical research institute of chemical defense, "Proceedings of the Annual Chemical Defense Bioscience Review (4th) Held at Aberdeen Proving Ground", Maryland, US (1984).