JOURNAL BROWSE
Search
Advanced SearchSearch Tips
Establishment of CTD Calibration System and Uncertainty Estimation
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
  • Journal title : Ocean and Polar Research
  • Volume 36, Issue 1,  2014, pp.77-85
  • Publisher : Korea Institute of Ocean Science & Technology
  • DOI : 10.4217/OPR.2014.36.1.077
 Title & Authors
Establishment of CTD Calibration System and Uncertainty Estimation
Lee, Jung-Han; Hwang, Keun-Choon; Kim, Eun-Soo; Lee, Seung-Hun;
  PDF(new window)
 Abstract
The quality control of ocean observations data is becoming a major issue as real-time observational data and information services have increased recently. Therefore, it is necessary for oceanographic instruments to calibrate. In this paper, we first introduce the CTD calibration system and traceability. Next, CTD calibration procedures and estimation of uncertainty of measurement are described. The expanded uncertainty (k = 2) of the temperature, pressure and conductivity are 0., and 0.006 mS/cm respectively. Finally, the excellence of CTD calibration and its measurement capability has been proven by comparing the inter-calibration result of KIOST and Sea-Bird Electronics (SBE). CTD calibration residuals are less than , MPa, S/m for SBE 3plus temperature sensor, SBE 19plus pressure sensor and SBE 4C conductivity sensor respectively.
 Keywords
CTD (Conductivity-Temperature-Depth);calibration;uncertainty;KOLAS;ISO/IEC 17025;
 Language
Korean
 Cited by
 References
1.
국립수산과학원 (2010) KODC NEWSLETTER. 국립수산과학원, SP-2010-ME-046, 40 p NFRDI (2010) (KODC Newsletter. National Fisheries Research and Development Institute, SP-2010-ME-046, 40 p (in Korean))

2.
이하웅, 박동원 (1991) CTD 시스템의 특성분석 및 비교. 해양연구 13(2):87-93(Lee HW, Park DW (1991) A comparison and analysis of characteristics of Two CTD Systems. Ocean Res 13(2): 87-93 (in Korean))

3.
최아라, 박영규, 민홍식, 김경홍 (2009) 후처리과정을 통한 CTD 관측 자료 품질 개선에 대하여. Ocean and Polar Res 31(4):339-347(Choi A-R, Park Y-G, Min HS, Kim KH (2009) The Improvement of CTD Data through Post Processing. Ocean and Polar Res 31(4):339-347 (in Korean)) crossref(new window)

4.
한국계량측정협회 (2003a) 표준백금저항온도계의 표준교정절차. 한국계량측정협회, KASTO 03-18-2040-117, 27 p (KASTO (2003a) Standard Calibration Procedure of Standard Platinum Resistance Thermometers. Korea Association of Standards & Testing Organizations, KASTO 03-18-2040-117, 27 p (in Korean))

5.
한국계량측정협회 (2003b) 아날로그 및 디지털 압력계의 표준교정절차. 한국계량측정협회, KASTO 03-09-1030-011, 26 p (KASTO (2003b) Standard Calibration Procedure of Analog or Digital Pressure Gauges. Korea Association of Standards & Testing Organization, KASTO 03-09-1030-011, 26 p (in Korean))

6.
한국계량측정협회 (2008) 온도 지시/기록/제어장치의 표준교정절차. 한국계량측정협회, KASTO 07-50103-116, 19 p (KASTO (2008) Standard Calibration Procedure of Temperature Indicators/Recorders/Controllers. Korea Association of Standards & Testing Organizations, KASTO 07-50103-116, 19 p (in Korean))

7.
한국표준과학연구원 (1999) 측정불확도 표현 지침. 한국표준과학연구원, KRISS-99-070-SP, 19 p (KRISS (1999) Guide to the expression of uncertainty in measurement. Korea Research Institute of Standards and Science, KRISS-99-070-SP, 19 p (in Korean))

8.
한국표준과학연구원 (2002) 국제 측정학 용어집. 한국표준과학연구원, KRISS-SP-2008-022, 126 p (KRISS (2002) Internal vocabulary of basic and general terms in metrology. Korea Research Institute of Standards and Science, KRISS-SP-2008-022, 126 p (in Korean))

9.
Kim Y-G, Kim K, Cho Y-K, Ossi H (2000) CTD data processing for CREAMS expeditions: thermal-lag correction of Sea-Bird CTD. J Korean Society of Oceanography 35(4):192-199

10.
Lewis EL (1980) The practical salinity scale 1978 and its antecedents. IEEE J Oceanic Eng 5(1):3-8 crossref(new window)

11.
Preston-Thomas H (1990) The International Temperature Scale of 1990 (ITS-90). Metrologia 27(1):3-10 crossref(new window)

12.
Sea-Bird Electronic (2007) SBE 19plus SEACAT Profiler User's Manual. Sea-Bird Electronic, Washington, 99 p

13.
Sea-Bird Electronic (2013) SBE 9plus CTD User's manual. Sea-Bird Electronic, Washington, 73 p