Exposure Level of Airborne Bacteria in the University Laboratories in Seoul, Korea
Hwang, Sung-Ho; Yoo, Kyong-Nam; Park, Ji-Ho; Park, Dong-Uk; Yoon, Chung-Sik;
  PDF(new window)
This study evaluated the bacterial concentrations and affecting factors at the laboratories of a university in Seoul, Korea. Thirty-three samples of total airborne bacteria (TAB) and eighteen samples of gram negative bacteria (GNB) were collected from both microbiology laboratories (7) and chemistry laboratories (6). GM (GSD) of TAB and GNB concentrations were 194 (2.52) , 24 (4.1) , respectively. TAB concentrations in the chemical laboratories (GM (GSD): 193 (2.0) ) were not significantly different from those in microbial laboratories (GM (GSD): 202 (2.7) , (p>0.05)). GM (GSD) of TAB concentrationsat the top of sink, the center of laboratory, and the front of ventilation ventilation device within laboratories, 182 (3.2) , 217 (2.2) , 176 (2.4) , respectively, were not significantly different (p=0.48). Related factors were measured such as temperature, relative humidity, floor of laboratory, number of persons and laboratory area. TAB concentrations were significantly related to temperature (r=0.36, p<0.05), and the floor of laboratory and temperature were also significantly related (r=0.49, p<0.001). However, other factors such as relative humidity, number of persons and laboratory area did not show any significant relationship with TAB concentrations (p>0.05). TAB concentrations were affected significantly by cleaning frequency (p<0.001) and floor of laboratory (p<0.05). There was also a significant difference (p<0.01) between TAB indoor concentrations and TAB outdoor concentrations. However, other factors such as general ventilation did not affect TAB concentrations (p>0.05) in this study.
total airborne bacteria;gram-negative bacteria;chemical laboratory;microbial laboratory;indoor;temperature;bioaerosol;
 Cited by
서울지하철 일부 역사 내 부유 곰팡이 농도 및 환경요인,황성호;안재경;박재범;

한국환경보건학회지, 2014. vol.40. 2, pp.81-87 crossref(new window)
Concentrations of Airborne Fungi and Environmental Factors in the Subway Stations in Seoul, Korea, Korean Journal of Environmental Health Sciences, 2014, 40, 2, 81  crossref(new windwow)
Xiang, L., Zhiqiang, J. Z. : Prompt tracking of indoor airborne contaminant source location with probability-based inverse multi-zone modeling. Building and Environment, 44, 1135-1143, 2009 crossref(new window)

American Conference of Governmental Industrial Hygienists (ACGIH) : Guidelines for the assessment of bioaerosols in the indoor environment. Cincinnati, Ohio, 1989

World Health Organization. Indoor air quality. :biological contaminants. WHO regional publications, European series no, 31, Copenhagen, 1999

Douwes, J., Thorne, P., Pearce, N., Heederik, D. :Bioaerosol health effects and exposure assessment progress and prospects. Annals of Occupational Hygiene, 47, 187-200, 2003 crossref(new window)

Owen, M. K., Ensor, D. S., Sparks, L. E. : Airborne particle sizes and sources found in indoor air. Atmospheric Environment, 26(A), 2149-2162, 1992 crossref(new window)

Kim, K. Y., Jeong, Y. I., Kim, C. N., Won, J. U.,Roh, J. H. : Distribution of airborne microorganism in the feedstuff manufacture factory. Korean Society of Occupational and Environmental Hygiene, 17(4), 335-342, 2007

Fisher, G., Muller, T., Schwalbe, R., Ostrowski, R.,Dott, W. : Exposure to airborne fungi, MVOC and mycotoxins in biowaste-handling facilities. International Journal of Hygiene and Environmental Health, 203, 97-104, 2000 crossref(new window)

Burge H. Bioareosols : prevalence and health effects in the indoor environment. Journal of Allergy Clinical Immunology, 86, 687-701, 1990 crossref(new window)

Lee, S. C., Guo, H., Li, W. M., Chan, L. Y. : Intercomparison of air pollutant concentrations in different indoor environment in Hong Kong. Atmospheric Environment, 36, 1929-1940, 2002 crossref(new window)

Awad, A. H. A. : Environmental study in subway metro stations in Cairo, Egypt. Journal of Occupational Health, 44, 112-118, 2002 crossref(new window)

Jo, W. K., Seo, Y. J. : Indoor and outdoor bioaerosol levels at recreation facilities, elementary schools, and homes. Chemospehre, 61, 1570-1579, 2005 crossref(new window)

Zuraimi, M. S., Tham, K. W. : Indoor air quality and its determinants in tropical child care centers. Atmospheric Environment, 42, 2225-2239, 2008 crossref(new window)

NIOSH (National Institute of Occupational, Safety and Health) : Sampling and characterization of bioaerosols. NIOSH Manual Analytical Methods, 4, 82-112, 1998

Bullock, W. H., Ignacio, J. S. : A Strategy for assessing and managing occupational exposures, 3rd ed

American Industrial Hygiene Association, Fairfax, VA, pp.349-355, 2006

Lee, S. C., Li, W. M., Ao, C. H. : Investigation of indoor air quality at residential homes in Hong Kong. Atmospheric Environment, 36, 225-237, 2002 crossref(new window)

Kim, K. Y., Roh, Y. M., Kim, Y. S., Lee, C. M.,Sim, I. S. : Profile of airborne microorganisms distributed in general offices. Korean Society of Occupational and Environmental Hygiene, 18(1), 11-19, 2008

Charriere. N., Droz. P., Oppliger. A. : Effects of bioaerosol exposure on work-related symptoms among Swiss sawmill workers. International Arch Occupational Environment Health, 1, 12-17, 2007

Guo, H., Lee, S. C., Chan, L. Y. : Indoor air quality investigation at air conditioned and non-air conditioned markets in Hong Kong. International Journal of Science Total Environment, 323, 87-98, 2004 crossref(new window)

Ren, P., Jankun, T. M., Belanger, K., Bracken, M.B., Leaderer, B. P. : The relation between fungal propagules in indoor air and home characteristics. Allergy, 56, 419-424, 2001 crossref(new window)

Tsai, M. Y., Liu, H. M. : Exposure to culturable airborne bioaerosols during noodle manufacturing in central Taiwan. International Journal of Science Total Environment, 10, 1016, 2008

Mui, K. W., Wong, L. T., Hui, P. S. : Risks of unsatisfactory airborne bacteria level in air-conditioned offices of subtropical climates. Building and Environment, 43, 475-479, 2008 crossref(new window)

Hirst, J. M., Stedman, O. J., Hogg, W. H. : Long distance spore transport : methods of measurement, vertical spore profiles and the detection of immigrant spores. Journal of General Microbiology, 48, 329-355, 1967 crossref(new window)

Scheff, P. A., Paulius, V. K., Curtis, L., Conroy, L. M. : Indoor air quality in a middle school, Part 2:development of emission factors for particulate matter and bioaerosols. Applied Occupational and Environmental Hygiene, 15, 835-842, 2000 crossref(new window)

Lee, J. H., Jo, W. K. : Characteristics of indoor and outdoor bioaerosals at Korean high-rise apartment buildings. Environmental Research, 101, 11-17, 2006 crossref(new window)