JOURNAL BROWSE
Search
Advanced SearchSearch Tips
Synthesis of Improved Polyaluminumchloride and Its Coagulation Properties
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
 Title & Authors
Synthesis of Improved Polyaluminumchloride and Its Coagulation Properties
Choi, Yong-Wook;
  PDF(new window)
 Abstract
The synthetic technology of improved polyaluminiumchloride (IPAC) similar to characteristics of PACS was established with minimum expense for modifying existing production line. The conditions for activating silicate was studied before the synthesis of IPAC, and the IPAC was synthesised with raw materials such as aluminumhydroxide and concentrated hydrochloric acid, followed by adding activated silicate and alginate. The specification of product, chemical structure, and coagulating properties were tested by using specification testing method, instrumental analytical method, and Jar tester, respectively. As a result, the product, IPAC, contained aluminium oxide content more than 17%, and no precipitation was shown at all while the IPAC solution was preserved, and the larger floc and faster coagulation were represented compared to existing PAC under the same conditions. It was suggested that these synthetic technology could be applied to the existing production line for producing PAC without approximately cost raising factor because of adding sulfuric acid-activated silicate instead of sodium sulfate.
 Keywords
Improved Polyaluminumchloride(IPAC);Coagulant;Silicate;Alginate;
 Language
Korean
 Cited by
 References
1.
손선관, 화학공업과 기술, 1984, 2(1), 36.

2.
최계운, 곽창호, 김량, 대한상하수도학회지, 1994, 2, 43.

3.
Huang, C.; Shiu, H. Colloids surfaces, 1996, 113, 155. crossref(new window)

4.
Gregor, J. E.; Nokes, C. J.; Fenton, E. Wat. Res., 1997,31(12), 2949. crossref(new window)

5.
Duan, J.; Wang, J.; Graham, N.; Wilson, F. Desalination,2002, 150, 1. crossref(new window)

6.
Duan, J.; Gregory, J. Colloids surfaces, 1996, 107, 309. crossref(new window)

7.
Kvech, S.; Edwards, M. Wat. Res. 2002, 36, 4356. crossref(new window)

8.
Schintu, M.; Meloni, P.; Contu, A. Ecotoxicol. Environ.Safety, 2000, 46, 29. crossref(new window)

9.
박선구, 송기봉, 양영모, 한국환경분석학회지, 2000,3(4), 189.

10.
주득종, 김윤영, 이석훈, 김영훈, 하태욱, 양승태, 최상준,한국물환경학회지, 2003, 19(1), 59.

11.
Barkacs, K.; Bohuss, I.; Bukovszky, A.; Varga, I.;Zaray, G. Microchem. J. 2000, 67, 271. crossref(new window)

12.
김미향, 김영만, 최범석, 분석과학회지, 1999, 12(6), 478.

13.
Gao, B. Y.; Hahn, H. H.; Hoffmann, E. Wat. Res. 2002,36, 3573. crossref(new window)

14.
한국공업규격, KS M 1510-1983.

15.
수처리제의 기준과 규격 및 표시기준 고시안, 환경부,1995.

16.
Standard method for the examination of water andwastewater, 16th Ed., APHA, Washington, DC, 1985.

17.
신정래, 수처리 약품, 동화기술, pp. 63-92, 1995.

18.
Gregor, J. E.; Fenton, E.; Brokenshire, G.; Brink, V. D.;O'sullivan, B. Wat. Res. 1996, 30(6), 1319. crossref(new window)

19.
Lu, X.; Chen, Z.; Yang, X. Wat. Res. 1999, 33(15), 3271. crossref(new window)

20.
Cathalifaud, G.; Mazet, J. A. M. Wat. Res. 1997, 31(4),689. crossref(new window)