The purpose of this study was to evaluate the perceived distance from home to high-voltage power lines using a transmission and substation geographic information system(TGIS). Of the 725, 136 respondents reported that high voltage power transmission tower, power lines or substation was within visual field range from home. Among them, 114 respondents reported valid address, which could be used in the analysis of TGIS. Forty two respondents(36.8 %) estimated that the power lines were closer and 15 respondents(13.2 %) estimated that they were farther than they actually were. Our current findings suggest that the reported distance from home to high-voltage power transmission towers, power lines, and substations cannot be used as a proxy for exposure to electromagnetic fields due to the low validity.
 Keywords
Electromagnetic Field;Transmission and Substation Geographic Information System;High-Voltage Power Transmission Tower;Risk Perception;
 Language
Korean
 Cited by
 References
1.
전인수, "고압선로에서 발생하는 전자기장의 위해성 관리 방안", 한국전자파학회논문지, 14(10), pp. 1017-1023. 2003년 10월.

2.
IARC(International Agency for Research on Cancer), Working Group on the Evaluation of Carcinogenic Risks to Humans. Non-ionizing Radiation, Part 1: Static and Extremely Low-Frequency(ELF) Electric and Magnetic Fields, IARC Press, 2002.

3.
World Health Organization, "Electromagnetic fields and public health: Exposure to extremely low frequency fields", Fact Sheet no. 322, World Health Organization, 2007.

4.
권범철, "밀양 송전탑 사태 일지", 창원:경남도민일보, 2013. [Accessed March 31, 2015]. http://www.idomin.com/news/articleView.html?idxno=427239

5.
홍여선. "당진 하늘은 '송전탑 거미줄'... 더 이상 NO!", 청주: 동양일보, 2014. [Accessed March 31, 2015]. http://www.dynews.co.kr/news/articleView.html?idxno=227219

6.
L. Kheifets, D. Renew, G. Sias, and J. Swanson, "Extremely low frequency electric fields and cancer: assessing the evidence", Bioelectromagnetics, vol. 31, no. 2, pp. 89-101, Feb. 2010.

7.
서경규, "송.변전설비에서의 자기장 발생 현황과 규제 기준", 대구경북개발연구, 11(3), pp. 1333-145, 2012년 12월.

8.
홍승철, 최성호, 김윤신, 박재영, "60 Hz 고압 송전선로의 자기장 발생범위에 대한 GIS 적용 방안에 대한 연구", 환경영향평가, 15(4), pp. 271-277, 2006년.

9.
대한전기학회, "가공 송전선로 전자계 노출량 조사 연구", 한국전력공사, 2010년.

10.
송해룡, 김원제, "원전주변 지역주민의 위험지각이 위험태도와 위험수용에 미치는 영향", 한국콘텐츠학회논문지, 12(6), pp. 238-248, 2012년.

11.
좌보경, 윤문영, 백혜진, "미디어, 지각된 위험 특성, 위험 인식의 관계에 대한 연구: 발암물질 위험 이슈를 중심으로", 홍보학연구, 17(4), pp. 72-109, 2013년 11월.

12.
송해룡, 김원제, "공중의 환경위험이슈에 대한 커뮤니케이션 행동 연구: 지구온난화 쟁점(상황)을 중심으로", 스피치와 커뮤니케이션, 23, pp. 273-309, 2014년 4월.

13.
T. Behrens, E. Lynge, I. Cree, S. Sabroe, J. M. Lutz, N. Afonso, M. Eriksson, P. Guenel, F. Merletti, M. Morales-Suarez-Varela, A. Stengrevics, J. Fevotte, A. Llopis-Gonzalez, G. Gorini, G. Sharkova, L. Hardell, and W. Ahrens, "Occupational exposure to electromagnetic fields and sex-differential risk of uveal melanoma", Occup. Environ. Med., vol. 67, no. 11, pp. 751-759, Nov. 2010. crossref(new window)

14.
옥민수, 임소윤, 김화정, 류현미, 이나리, 이무송, "보건의료계 종사자들의 전자기장에 대한 위험 인식", 대한임상건강증진학회지, 15(2), pp. 39-46, 2015년.

15.
KEPCO KDN, "Transmission & Substation Geographic Information System". [Accessed March 31, 2015]. https://www.kdn.com/home3/we/gs/WEGS_0311.jsp

16.
Road Name Address, Ministry of Government Administration and Home Affairs. [Accessed March 31, 2015]. http://www.juso.go.kr/openEngPage.do

17.
V. Wunsch-Filho, D. M. Pelissari, F. E. Barbieri, L. Sant'Anna, C. T. de Oliveira, J. F. de Mata, L. G. Tone, M. L. Lee, M. L. de Andrea, P. Bruniera, S. Epelman, V. O. Filho, and L. Kheifets, "Exposure to magnetic fields and childhood acute lymphocytic leukemia in São Paulo, Brazil", Cancer Epidemiol., vol. 35, no. 6, pp. 534-539, Dec 2011. crossref(new window)

18.
김현봉, 김완기, 이영수, 전완표, "이동 통신 기지국 주변 전자파강도 인체 노출량 분석", 한국전자파학회논문지, 24(5), pp. 525-533, 2003년 5월.

19.
송해주, 김순영, 이문호, "이동 통신용 기지국 환경에서 전자파 강도 노출량 측정 결과 분석", 한국전자파학회논문지, 21(6), pp. 601-609, 2010년 6월.

20.
C. Sermage-Faure, C. Demoury, J. Rudant, S. Goujon-Bellec, A. Guyot-Goubin, F. Deschamps, D. Hemon, and J. Clavel, "Childhood leukaemia close to high-voltage power lines-the Geocap study, 2002-2007", Br. J. Cancer, vol. 108, no. 9, pp. 1899-1906, May 2013. crossref(new window)

21.
M. R. Sohrabi, T. Tarjoman, A. Abadi, and P. Yavari, "Living near overhead high voltage transmission power lines as a risk factor for childhood acute lymphoblastic leukemia: a case-control study", Asian Pac. J. Cancer. Prev., vol. 11, no. 2, pp. 423-427, 2010.

22.
송해룡, 김원제, 정세일, "과학기술 위험에 대한 인지 및 태도: 전자파 위험을 중심으로", 한국콘텐츠학회논문지, 10(5), pp. 436-445, 2010년 5월.

23.
김경희, 송대종, 최재욱, "휴대전화 전자파 위험인식과 리스크커뮤니케이션: 여성의 위험인식을 중심으로", 한국전자통신학회논문지 8(7), pp. 1065-1074. 2013년 7월.

24.
조성은, 유선욱, "위험지각태도와 규범이 자궁경부암 예방행동의도에 미치는 영향에 대한 연구: 우리나라 여대생을 대상으로 한 RPA 모델 적용을 중심으로", 홍보학연구, 15(1), pp. 58-98. 2011년 2월.