Investigation of the link beam length of a coupled steel plate shear wall
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
 Title & Authors
Investigation of the link beam length of a coupled steel plate shear wall
Gholhaki, M.; Ghadaksaz, M.B.;
 Abstract
Steel shear wall system has been used in recent years in tall buildings due to its appropriate behavior advantages such as stiffness, high strength, economic feasibility and high energy absorption capability. Coupled steel plate shear walls consist of two steel shear walls that are connected to each other by steel link beam at each floor level. In this article the frames of 3, 10, and 15 of (C-SPSW) floor with rigid connection were considered in three different lengths of 1.25, 2.5 and 3.75 meters and link beams with plastic section modulus of 100% to the panel beam at each floor level and analyzed using three pairs of accelerograms based on nonlinear dynamic analysis through ABAQUS software and then the performance of walls and link beams at base shear, drift, the period of structure, degree of coupling (DC) and dissipated energy evaluated. The results show that the (C-SPSW) system base shear increases with a decrease in the link beam length, and the drift, main period and dissipated energy of structure decreases. Also the link beam length has different effects on parameters of coupling degrees.
 Keywords
coupled steel plate shear wall;link beam;nonlinear dynamic analysis;plastic section modulus;
 Language
English
 Cited by
1.
Hysteretic behavior of coupled steel plate shear walls, Journal of Constructional Steel Research, 2017, 133, 19  crossref(new windwow)
 References
1.
ABAQUS (2011), Standard Version 6.11, and ABAQUS standard user's manual.

2.
AISC (2005), Seismic Provisions for Structural Steel Buildings, American Institute of Steel Construction; Chicago, IL, USA.

3.
AISC (2010), Seismic Provisions for Structural Steel Building, American Institute of Steel Construction; Chicago, IL, USA.

4.
Borello, D.J. and Fahnestock, L.A. (2011), "Design and testing of coupled steel plate shear walls", Structures Congress 2011, ASCE, Las Vegas, NV, USA, April, pp. 736-747.

5.
Borello, D.J. and Fahnestock, L.A. (2012a), "Behavior and mechanisms of steel plate shear walls with coupling", J. Construct. Steel Res., 74, 8-16. crossref(new window)

6.
Borello, D.J. and Fahnestock, L.A. (2012b), "Seismic design and analysis of steel plate shear walls with coupling", Journal of Structural Engineering, 139, 1263-1273.

7.
CSA (2001), Limit states design of steel structures, Canadian Standards Association; CAN/CSA S16-01, Willowdale, ON, Canada.

8.
Gholhaki, M. (2007), "Investigating the behavior of ductile SPSW and the effect of beam-to-column connection type on them", Ph.D. Dissertation; Civil Engineering Department, Khajeh Nasir Toosi University of Technology.

9.
Harries, K.A., Moulton, J.D. and Clemson, R.L. (2004), "Parametric study of coupled wall Behavior-implications for the design of coupling beams", J. Struct. Eng., 130(3), 480-488. crossref(new window)

10.
Jadhav, M.B. and Patil, G.R. (2014), "Review on steel plate shear wall for tall buildings", Int. J. Sci. Res. (IJSR), 973-978.

11.
Li, C.H., Tsai, K.C., Chang, J.T. and Lin, C.H. (2011), "Cyclic test of a coupled steel plate shear wall substructure", Procedia Eng., 14(1), 582-589. crossref(new window)

12.
Li, C.-H., Chang, J.-T., Tsai, K.-C. and Lin, C.-H. (2011), "Recent experimental researches on steel plate shear walls in NCREE", Structures Congress 2011, ASCE, Las Vegas, NV, USA, April, pp. 724-735.

13.
Regulations for seismic design of buildings (2005), 2800, (3rd edition), Building and Housing Research Center.

14.
The sixth issue of the Iranian National Building Regulations (loads on the building) (2009).

15.
Thorburn, L.J., Kulak, G.L. and Montgomery, C.J. (1983), "Analysis of Steel Plate Shear Walls", Structural Engineering Report No. 107, Department of Civil Engineering, University of Alberta, Edmonton, AL, Canada.

16.
Vatansever, C. and yardimci, N. (2011), "Experimental investigation of thin steel plate shear walls with different infill-to-boundary frame connections", Steel Compos. Struct., Int. J., 11(3), 251-271. crossref(new window)

17.
Zhao, Q. and Astaneh-Asl, A. (2004), "Cyclic behavior of traditional and innovative composite shear walls", J. Struct. Eng., 130(2), 271-284. crossref(new window)