 Abstract
The progressive collapse phenomenon in structures has been interested by civil engineers and the building standards organizations. This is particularly true for the tall and special buildings ever since local collapse of the Ronan Point tower in UK in 1968. When initial or secondary defects of main load carrying elements, overloads or unpredicted loads occur in the structure, a local collapse may be arise that could be distributed through entire structure and cause global collapse. One is not able to prevent the reason of failure as well as the prevention of propagation of the collapse. Also, one is not able to predict the start point of collapse. Therefore we should generalize design guides to whole or the part of structure based on the risk analysis and use of load carrying elements removal scenario. There are some new guides and criteria for elements and connections to be designed to resist progressive collapse. In this paper, codes and recommendations by various researchers are presented, classified and compared for steel structures. Two current design methods are described in this paper and some retrofitting methods are summarized. Finally a steel building with special moment resistant frame is analyzed as a case study based on two standards guidelines. This includes consideration of codes recommendations. It is shown that progressive collapse potential of the building depends on the removal scenario selection and type of analysis. Different results are obtained based on two guidelines.
 Keywords
progressive collapse;steel frame structures;direct and indirect design;AP method;retrofitting methods;
 Language
English
 Cited by
1.
Effects of damping ratio on dynamic increase factor in progressive collapse,;;

Steel and Composite Structures, 2016. vol.22. 3, pp.677-690 crossref(new window)
2.
Progressive collapse analysis of steel building considering effects of infill panels,;;

Structural Engineering and Mechanics, 2016. vol.59. 1, pp.59-82 crossref(new window)
3.
Progressive collapse analysis of steel frame structure based on the energy principle,;;;;

Steel and Composite Structures, 2016. vol.21. 3, pp.553-571 crossref(new window)
1.
Effects of damping ratio on dynamic increase factor in progressive collapse, Steel and Composite Structures, 2016, 22, 3, 677  crossref(new windwow)
2.
Progressive collapse analysis of steel building considering effects of infill panels, Structural Engineering and Mechanics, 2016, 59, 1, 59  crossref(new windwow)
3.
Effects of Postelastic Stiffness Ratio on Dynamic Increase Factor in Progressive Collapse, Journal of Performance of Constructed Facilities, 2017, 31, 6, 04017107  crossref(new windwow)
4.
Progressive collapse analysis of steel frame structure based on the energy principle, Steel and Composite Structures, 2016, 21, 3, 553  crossref(new windwow)
 References
1.
AISC (2005), American Institute of Steel Construction, Seismic provisions for structural steel buildings, Chicago, IL, USA.

2.
ASCE 7-02 (2006), Minimum Design Loads for Buildings and other Structures.

3.
Crawford, J.E. (2002), "Retrofit methods to mitigate progressive collapse, the multi hazard mitigation council of the national institute of building sciences", Report on the National Workshop and Recommendations for Future Effort.

4.
DoD (2013), UFC 4-023-03: Design of Building to Resist Progressive Collapse, Department of Defense, Washington, D.C., USA.

5.
FEMA 356 (2000), Pre-standard and Commentary for the Seismic Rehabilitation of Buildings, Building Seismic Safety Council for the Federal Emergency Management Agency.

6.
GSA (General Services Administration) (2003), Progressive Collapse Analysis and Design Guidelines for New Federal Office Buildings and Major Modernization Projects, Washington, DC.

7.
Kaewkulchai, G. and Williamson, E.B. (2003), "Dynamic behavior of planar frames during progressive collapse", Proceedings of the 16th ASCE Engineering Mechanics Conference.

8.
Kandil, K.S., El Fattah Ellobody, E.A. and Eldehemy, H. (2013), "Progressive collapse of steel frames", World J. Eng. Technol., 1, 39-48. crossref(new window)

9.
Kim, J.K. and Park, J.H. (2008), "Design of steel moment frames considering progressive collapse", Steel Compos. Struct., Int. J., 8(1), 85-98. crossref(new window)

10.
Kim, J.K., Park, J.H. and Lee, T.H. (2011), "Sensitivity analysis of steel buildings subjected to column loss", Eng. Struct., 33(2), 421-432. crossref(new window)

11.
Leyendecker, E.V. and Burnett, E. (1976), The incidence of abnormal loading in residential buildings, Building Science Series No. 89; National Bureau of Standards, Washington, D.C., USA.

12.
Liu, M. (2011), "Progressive collapse design of seismic steel frames using structural optimization", J. Construct. Steel Res., 67(3), 322-332. crossref(new window)

13.
Lu, X.Z., Li, Y., Ye, L.P., Ma, Y.F. and Liang, Y. (2008), "Study on the design methods to resist progressive collapse for structures", Proceedings of the 10th International Symposium on Structural Engineering for Young Experts, Changsha, China, October.

14.
Marjanishvili, S.M. (2004), "Progressive analysis procedure for progressive collapse", J. Perform. Construct. Facil., 18(2), 79-85. crossref(new window)

15.
Marjanishvili, S. and Agnew, E. (2006), "Comparison of Various Procedures for Progressive Collapse Analysis", ASCE J. Perform. Construct. Facil., 20(4), 356-374.

16.
Mirtaheri, M. and Abbasi Zoghi, M. (2012), "On the analysis and design of steel structure to mitigate progressive collapse", Adv. Mater. Res., 378-379, 775-779.

17.
National Building Code of Canada (1995), National Research Council of Canada, OT, Canada.

18.
National Institute of Standards and Technology (2006), Best Practices for Reducing the Potential for Progressive Collapse in Buildings.

19.
Rezvani, F.H. and Asarian, B. (2014), "Effect of seismic design level on safety against progressive collapse of concentrically braced frames", Steel Compos. Struct., Int. J., 16(2), 135-156. crossref(new window)

20.
Rezvani, F.H., Yousefi, A. and Ronagh, H. (2015), "Effect of span length on progressive collapse behaviour of steel moment resisting frames", Structures, 3, 81-89. DOI: 10.1016/j.istruc.2015.03.004 crossref(new window)

21.
Sasani, M. and Sagiroglu, S. (2008), "Progressive collapse resistance of Hotel San Diego", ASCE J. Struct. Eng., 134(3), 478-488. crossref(new window)

22.
SCE (2006), Standard 7-05: Minimum design loads for buildings and other structures.