Axial compressive behaviour of circular CFFT: Experimental database and design-oriented model
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
 Title & Authors
Axial compressive behaviour of circular CFFT: Experimental database and design-oriented model
Khan, Qasim S.; Sheikh, M. Neaz; Hadi, Muhammad N.S.;
 Abstract
Concrete Filled Fibre Reinforced Polymer Tube (CFFT) for new columns construction has attracted significant research attention in recent years. The CFFT acts as a formwork for new columns and a barrier to corrosion accelerating agents. It significantly increases both the strength capacity (Strength enhancement ratio) and the ductility (Strain enhancement ratio) of reinforced concrete columns. In this study, based on predefined selection criteria, experimental investigation results of 134 circular CFFT columns under axial compression have been compiled and analysed from 599 CFFT specimens available in the literature. It has been observed that actual confinement ratio (expressed as a function of material properties of fibres, diameter of CFFT and compressive strength of concrete) has significant influence on the strength and ductility of circular CFFT columns. Design oriented models have been proposed to compute the strength and strain enhancement ratios of circular CFFT columns. The proposed strength and strain enhancement ratio models have significantly reduced Average Absolute Error (AAE), Mean Square Error (MSE), Relative Standard Error of Estimate (RSEE) and Standard Deviation (SD) as compared to other available strength and strain enhancement ratios of circular CFFT column models. The predictions of the proposed strength and strain enhancement ratio models match well with the experimental strength and strain enhancement ratios investigation results in the compiled database.
 Keywords
column;CFFT;confinement ratio;strength enhancement ratio;strain enhancement ratio;
 Language
English
 Cited by
1.
Axial-Flexural Interactions of GFRP-CFFT Columns with and without Reinforcing GFRP Bars, Journal of Composites for Construction, 2017, 21, 3, 04016109  crossref(new windwow)
2.
Concrete Filled Carbon FRP Tube (CFRP-CFFT) columns with and without CFRP reinforcing bars: Axial-flexural interactions, Composites Part B: Engineering, 2018, 133, 42  crossref(new windwow)
 References
1.
Aslani, F., Uy, B., Tao, Z. and Mashiri, F. (2015), "Predicting the axial load capacity of high-strength concrete filled steel tubular columns", Steel Compos. Struct., Int. J., 19(4), 967-99. crossref(new window)

2.
Berthet, J., Ferrier, E. and Hamelin, P. (2005), "Compressive behaviour of concrete externally confined by composite jackets. Part A: Experimental study", Construct. Build. Mater., 19(3), 223-232. crossref(new window)

3.
Choi, K. and Xiao, Y. (2010), "Analytical studies of concrete-filled circular steel tubes under axial compression", J. Struct. Eng., 136(5), 565-573. crossref(new window)

4.
Cole, B. and Fam, A. (2006), "Flexural load testing of concrete-filled FRP tubes with longitudinal steel and FRP rebar", J. Compos. Construct., 10(2), 161-171. crossref(new window)

5.
De Lorenzis, L. and Tepfers, R. (2003), "Comparative study of models on confinement of concrete cylinders with Fiber-Reinforced Polymer composites", J. Compos. Construct., 7(3), 219-237. crossref(new window)

6.
Demers, M. and Neale, K. (1994), "Strengthening of concrete columns with unidirectional composite sheets", Develop. Short Medium Span Bridge Eng., 94, 895-905.

7.
Fam, A. and Rizkalla, S. (2001a), "Concrete filled FRP tubes for flexural and axial compression members", Proceedings of ACMBS-3, 315-322.

8.
Fam, A.Z. and Rizkalla, S.H. (2001b), "Behaviour of axially loaded concrete filled circular fiber reinforced polymer tubes", ACI Struct. J., 98(3), 280-289.

9.
Fam, A. and Rizkalla, S. (2002), "Flexural behavior of concrete-filled fiber-reinforced polymer circular tubes", J. Compos. Construct., 6(2), 123-132. crossref(new window)

10.
Fam, A., Schnerch, D. and Rizkalla, S. (2005), "Rectangular filament-wound Glass Fiber Reinforced Polymer tubes filled with concrete under flexural and axial loading: Experimental investigation", J. Compos. Construct., 9(1), 25-33. crossref(new window)

11.
Hadi, M.N.S., Wang, W. and Sheikh, M.N. (2015), "Axial compressive behaviour of GFRP tube reinforced concrete columns", Construct. Build. Mater., 81, 198-207. crossref(new window)

12.
Hadi, M.N.S., Khan, Q.S. and Sheikh, M.N. (2016), "Axial and flexural behavior of unreinforced and FRP bar reinforced circular concrete filled FRP tube columns", Construct. Build. Mater., 122, 43-53. crossref(new window)

13.
Han, L., Yao, G. and Zhao, X. (2004), "Behaviour and calculation on concrete-filled steel CHS (Circular Hollow Section) beam-columns", Steel Compos. Struct., Int. J., 4(3), 169-188. crossref(new window)

14.
Harries, K.A. and Carey, S.A. (2002), "Shape and gap effects on the behaviour of variably confined concrete", Cement Concrete Res., 33(6), 881-890.

15.
Hong, W.K. and Kim, H.C. (2004), "Behaviour of concrete columns confined by carbon composites tubes", Can. J. Civil Eng., 31(2), 178-188. crossref(new window)

16.
Idris, Y. and Ozbakkaloglu, T. (2013), "Seismic behavior of high-strength concrete-filled FRP tube columns", J. Compos. Construct., 17(6), 04013013. crossref(new window)

17.
Ishizawa, T., Nakano, T. and Iura, M. (2006), "Experimental study on partially concrete-filled steel tubular columns", Steel Compos. Struct., Int. J., 6(1), 55-69. crossref(new window)

18.
Johannson, M. (2003), "Composite action in connection regions of concrete-filled steel tube columns", Steel Compos. Struct., Int. J., 3(1), 47-64. crossref(new window)

19.
Jolly, C.K. and Lillistone, D. (1998a), "Concrete filled FRP circular columns under eccentric loading", Proceedings of the 7th International conference on Fibre Reinforced Composites, (P.A.G Gibson Ed.), Woodhead Publishing Ltd., University of Newcastle upon Tyne, UK.

20.
Jolly, C.K. and Lillistone, D. (1998b), "The stress strain behaviour of concrete confined by advanced fiber composites", Proceedings of the 8th BCA Annual Conference on Higher Education and the Concrete Industry, (U.o. Southampton Ed.), England, UK, July.

21.
Karbhari, V. and Gao, Y. (1997), "Composite jacketed concrete under uniaxial compression-verification of simple design equations", J. Mater. Civil Eng., 9(4), 185-193. crossref(new window)

22.
Lam, L. and Teng, J. (2002), "Strength models for fiber-reinforced plastic-confined concrete", J. Struct. Eng., 128(5), 612-623. crossref(new window)

23.
Lam, L. and Teng, J.G. (2003), "Design-oriented stress-strain model for FRP-confined concrete", Construct. Build. Mater., 17(6-7), 471-489. crossref(new window)

24.
Lee, S. (2007), "Capacity and the moment-curvature relationship of high strength concrete filled steel tube columns under eccentric loads", Steel Compos. Struct., Int. J., 7(2), 135-160. crossref(new window)

25.
Li, y., Yan, X. and Ou, J.P. (2007), "Compressive behaviour and non linear analysis of self sensing concrete filled FRP tubes and FRP steel Composite tubes", Proceedings of the 8th International Symposium on Fiber Reinforced Polymer Reinforcement for Concrete Structures, Patras, Greece, July.

26.
Lillistone, D. and Jolly, C.K. (1997), "Concrete filled fibre reinforced plastic circular columns", Proceedings of Composite Construction-Conventional and Innovative Conference, Composite Construction-Conventional and Innovative, Innsbruck, Austria, September.

27.
Lillistone, D. and Jolly, C.K. (2000), "An innovative form of reinforcement for concrete columns using advanced composites", The Struct. Eng., 78(23-24), 20-29.

28.
Lim, J.C. and Ozbakkaloglu, T. (2014), "Confinement model for FRP-confined high-strength concrete", J. Compos. Construct., 18(4), 04013058. crossref(new window)

29.
Masmoudi, R. and Mohamed, H. (2011), "Axial behaviour of slender concrete filled FRP tube columns reinforced with steel and carbon FRP bars", Proceedings of the 10th International Symposium on Fiber- Reinforced Polymer Reinforcement for Concrete Structures, Tampa, FL, USA, April.

30.
Mastrapa, J.C. (1997), "Effect of construction bond on confinement with fibre composites", Masters; University of Florida, FL, USA.

31.
Matthys, S., Taerwe, L. and Audenaert, K. (1999), "Tests on axially loaded concrete columns confined by fibre reinforced polymer sheet wrapping", In: (C.W. Dolan, S.H. Rizkalla, A. Nanni Ed.), FRPRCS-4, American Concrete Institute, MI, USA.

32.
Mirmiran, A. and Shahawy, M. (1996), "A new concrete-filled hollow FRP composite column", Compos. Part B: Eng., 27(3-4), 263-268.

33.
Mirmiran, A. and Shahawy, M. (1997), "Behaviour of concrete columns confined by fiber composites", J. Struct. Eng., 123(5), 583-590. crossref(new window)

34.
Mirmiran, A., Samaan, M., Cabrera, S. and Shahawy, M. (1998a), "Design, manufacture and testing of a new hybrid column", Construct. Build. Mater., 12(1), 39-49. crossref(new window)

35.
Mirmiran, A., Shahawy, M. and Samaan, M. (1998b), "Strength and ductility of hybrid FRP-concrete beamcolumns", J. Struct. Eng., 125(10), 1085-1093.

36.
Mirmiran, A., Shahawy, M., Samaan, M., EL Echary, H., Mastrapa, J.C. and Pico, O, (1998c), "Effect of column parameters on FRP confined concrete", J. Compos. Construct., 2(4), 175-185. crossref(new window)

37.
Mohamed, H. and Masmoudi, R. (2008a), "Behavior of the concrete filled FRP tube columns under eccentric load", Structural Composites for Infrastructure Applications (MESC-5), Hurghada, Egypt.

38.
Mohamed, H. and Masmoudi, R. (2008b), "Compressive behaviour of reinforced concrete filled FRP tubes", Special Publication, 257, 91-108.

39.
Mohamed, H. and Masmoudi, R. (2010), "Axial load capacity of concrete-Filled FRP tube columns: Experimental versus theoretical predictions", J. Compos. Construct., 14(2), 231-243. crossref(new window)

40.
Nanni, A. and Bradford, N.M. (1995), "FRP jacketed concrete under uniaxial compression", Construct. Build. Mater., 9(2), 115-124. crossref(new window)

41.
Ozbakkaloglu, T. (2013a), "Axial compressive behavior of square and rectangular high-strength concretefilled FRP tubes", J. Compos. Construct., 17(1), 151-161. crossref(new window)

42.
Ozbakkaloglu, T. (2013b), "Compressive behavior of concrete-filled FRP tube columns: Assessment of critical column parameters", Eng. Struct., 51, 188-199. crossref(new window)

43.
Ozbakkaloglu, T. and Lim, J.C. (2013), "Axial compressive behaviour of FRP confined concrete: Experimental test database and a new design oriented model", Compos. Part B: Eng., 55, 607-634. crossref(new window)

44.
Ozbakkaloglu, T. and Oehlers, D. (2008a), "Concrete-filled square and rectangular FRP tubes under axial compression", J. Compos. Construct., 12(4), 469-477. crossref(new window)

45.
Ozbakkaloglu, T. and Oehlers, D.J. (2008b), "Manufacture and testing of a novel FRP Tube confinement system", Eng. Struct., 30(9), 2448-2459. crossref(new window)

46.
Ozbakkaloglu, T. and Saatcioglu, M. (2006), "Seismic behavior of high-strength concrete columns confined by fiber-reinforced polymer tubes", J. Compos. Construct., 10(6), 538-549. crossref(new window)

47.
Ozbakkaloglu, T. and Vincent, T. (2013), "Axial compressive behavior of circular high-strength concretefilled FRP tubes", J. Compos. Construct., 18(2), 04013037-1-11.

48.
Ozbakkaloglu, T., Lim, J.C. and Vincent, T. (2012), "FRP confined concrete in circular sections: Review and assessment of stress strain models", Eng. Struct., 49, 1068-1088.

49.
Park, J.W. and Choi, S.M. (2013), "Structural behaviour of CFRP strengthened concrete-filled steel tubes columns under axial compression loads", Steel Compos. Struct., Int. J., 14(5), 453-472. crossref(new window)

50.
Park, J.H., Jo, B.W., Yoon, S.J. and Park, S.K. (2011), "Experimental investigation on the structural behaviour of concrete filled FRP tubes with/without steel rebar", KSCE J. Civil Eng., 15(2), 337-345. crossref(new window)

51.
Pham, T. and Hadi, M. (2013), "Strain estimation of CFRP-confined concrete columns using energy approach", J. Compos. Construct., 17(6), 04013001. crossref(new window)

52.
Pham, T. and Hadi, M. (2014a), "Predicting stress and strain of FRP-confined square/rectangular columns using artificial neural networks", J. Compos. Construct., 18(6), 04014019. crossref(new window)

53.
Pham, T. and Hadi, M. (2014b), "Stress prediction model for FRP confined rectangular concrete columns with rounded corners", J. Compos. Construct., 18(1), 04013019. crossref(new window)

54.
Realfonzo, R. and Napoli, A. (2011), "Concrete confined by FRP systems: Confinement efficiency and design strength models", Compos. Part B: Eng., 42(4), 736-755. crossref(new window)

55.
Richart, F.E., Brandtzaeg, A. and Brown, R.L. (1928), "A study of the failure of concrete under combined compressive stresses", University of Illinois Bulletin; University of Illinois, Urbana, IL, USA.

56.
Saafi, M., Toutanji, H.A. and Li, Z. (1999), "Behaviour of concrete columns confined with fiber reinforced polymer tubes", ACI Mater. J., 96(4), 500-509.

57.
Saaman, M., Mirmiran, A. and Shahawy, M. (1998), "Model of concrete confined by fibre composites", Journal of Structural Engineering, 124(9), 1025-1031. crossref(new window)

58.
Sadeghian, P. and Fam, A. (2015), "Improved design-oriented confinement models for FRP-wrapped concrete cylinders based on statistical analyses", Eng. Struct., 87, 162-182. crossref(new window)

59.
Sakino, K., Nakahara, H., Morino, S. and Nishiyama, I. (2004), "Behavior of centrally loaded concrete-filled steel-tube short columns", J. Struct. Eng., 130(2), 180-188. crossref(new window)

60.
Tegola, L.A. and Manni, D. (1999), "Experimental investigation on concrete confined by fibre reinforced polymer and comparisons with theoretical model", In: (C.W. Dolan, S.H. Rizkalla, A. Nanni Ed.), FRPRCS-4; American Concrete Institute, MI, USA.

61.
Toutanji, H.A. (1999), "Stress-strain characteristics of concrete columns externally confined with advanced fibre composite sheets", ACI Mater. J., 96(3), 397-404.

62.
Vincent, T. and Ozbakkaloglu, T. (2013a), "Influence of concrete strength and confinement method on axial compressive behaviour of FRP confined high and ultra high strength concrete", Compos. Part B: Eng., 50, 413-428. crossref(new window)

63.
Vincent, T. and Ozbakkaloglu, T. (2013b), "Influence of fibre orientation and specimen end condition on axial compressive behaviour of FRP confined concrete", Construct. Build. Mater., 47, 814-826. crossref(new window)

64.
Woo, P.J., Kyun, H.Y. and Mo, C.S. (2010), "Behaviours of concrete filled square steel tubes confined by carbon fiber sheets (CFS) under compression and cyclic loads", Steel Compos. Struct., Int. J., 10(2), 187-205. crossref(new window)

65.
Wu, G., Lu, Z. and Wu, Z. (2006), "Strength and ductility of concrete cylinders confined with FRP composites", J. Construct. Build. Mater., 20(3), 134-138. crossref(new window)

66.
Wu, Y.F. and Jiang, C. (2013), "Effect of load eccentricity on the stress-strain relationship of FRP-confined concrete columns", Compos. Struct., 98, 228-241. crossref(new window)

67.
Yamakawa, T., Zhong, P. and Ohama, A. (2003), "Seismic performance of aramid fiber square tubed concrete columns with metallic and/or non-metallic reinforcement", J. Reinf. Plast. Compos., 22(13), 1221-1238. crossref(new window)

68.
Youssef, M., Feng, M. and Mosallam, A. (2007), "Stress strain model for concrete confined by FRP composites", Compos. Part B : Eng., 38(5-6), 614-628. crossref(new window)

69.
Zhao, X., Grzebieta, R. and Elchalakani, M. (2002), "Tests of concrete-filled double skin CHS composite stub columns", Steel Compos. Struct., Int. J., 2(2), 129-146. crossref(new window)