JOURNAL BROWSE
Search
Advanced SearchSearch Tips
Seismic isolation performance sensitivity to potential deviations from design values
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
  • Journal title : Smart Structures and Systems
  • Volume 18, Issue 2,  2016, pp.293-315
  • Publisher : Techno-Press
  • DOI : 10.12989/sss.2016.18.2.293
 Title & Authors
Seismic isolation performance sensitivity to potential deviations from design values
Alhan, Cenk; Hisman, Kemal;
 Abstract
Seismic isolation is often used in protecting mission-critical structures including hospitals, data centers, telecommunication buildings, etc. Such structures typically house vibration-sensitive equipment which has to provide continued service but may fail in case sustained accelerations during earthquakes exceed threshold limit values. Thus, peak floor acceleration is one of the two main parameters that control the design of such structures while the other one is peak base displacement since the overall safety of the structure depends on the safety of the isolation system. And in case peak base displacement exceeds the design base displacement during an earthquake, rupture and/or buckling of isolators as well as bumping against stops around the seismic gap may occur. Therefore, obtaining accurate peak floor accelerations and peak base displacement is vital. However, although nominal design values for isolation system and superstructure parameters are calculated in order to meet target peak design base displacement and peak floor accelerations, their actual values may potentially deviate from these nominal design values. In this study, the sensitivity of the seismic performance of structures equipped with linear and nonlinear seismic isolation systems to the aforementioned potential deviations is assessed in the context of a benchmark shear building under different earthquake records with near-fault and far-fault characteristics. The results put forth the degree of sensitivity of peak top floor acceleration and peak base displacement to superstructure parameters including mass, stiffness, and damping and isolation system parameters including stiffness, damping, yield strength, yield displacement, and post-yield to pre-yield stiffness ratio.
 Keywords
sensitivity analysis;seismic isolation;linear isolation system;nonlinear isolation system;seismic performance;
 Language
English
 Cited by
 References
1.
Alhan, C. and Gavin, H.P. (2004), "A parametric study of linear and non-linear passively damped seismic isolation systems for buildings", Eng. Struct., 26(4), 485-497. crossref(new window)

2.
Alhan, C. and Ozgur, M. (2015), "Seismic responses of base-isolated buildings: efficacy of equivalent linear modeling under near-fault earthquakes", Smart Struct. Syst., 15(6), 1439-1461. crossref(new window)

3.
Alhan, C. and Surmeli, M. (2011), "Shear building representations of seismically isolated buildings", Bull. Earthq. Eng., 9, 1643-1671. crossref(new window)

4.
Benzoni, G. (editor) (2015), Proceedings on electronic key of the 14th world conference on seismic isolation, energy dissipation and active vibration control of Structures, San Diego, California, USA, September 9-11, 2015.

5.
Casciati, S., Chassiakos, A.G. and Masri, S.F. (2014), "Toward a paradigm for civil structural control", Smart Struct. Syst., 14(5), 981-1004. crossref(new window)

6.
Charmpis, D.C., Komodromos, P. and Phocas, M.C. (2012), "Optimized earthquake response of multi-storey buildings with seismic isolation at various elevations", Earthq. Eng. Struct. D., 41(15), 2289-2310.

7.
Cheng, F.Y., Jiang, H. and Lou, K. (2008), Smart structures: Innovative systems for seismic response control, CRC Press, Taylor & Francis Group, Boca Raton.

8.
Chopra, A.K. (2001), Dynamics of structures: Theory and applications to earthquake engineering, 2nd edition, Pearson Education, Inc, NJ, USA.

9.
Contento, A. and Di Egidio, A. (2014), "On the use of base isolation for the protection of rigid bodies placed on a multi-storey frame under seismic excitation", Eng. Struct., 62-63, 1-10. crossref(new window)

10.
Falsone, G. and Ferro, G. (2006), "Best performing parameters of linear and non-linear seismic base isolator systems obtained by the power flow analysis", Comput. Struct., 84(31-32), 2291-2305. crossref(new window)

11.
Gavin, H., Alhan, C. and Oka, N. (2003), "Fault-tolerance of semiactive isolation", J. Struct. Eng.-ASCE, 129(7), 922-932. crossref(new window)

12.
Guo, T., Xu, W., Song, L.L. and Wei, W. (2014), "Seismic-isolation retrofits of school buildings: Practice in china after recent devastating earthquakes", J. Perform. Constr. Fac., 9, 147-171.

13.
Hirata, K., Shiojiri, H., Mazda, T. and Kontani, O. (1989), "Response variability of isolated structure due to randomness of isolation devices", ICOSSAR 89, Proceedings of the 5th International Conference on Structural Safety and Reliability, San Francisco, 7-11 August, 1989.

14.
Hisman, K. (2011), "Sensitivity of the performances of seismic isolation platforms to small deviations in mechanical properties of seismic isolators", MSc Thesis, Department of Civil Engineering, Institute of Science, Istanbul University (in Turkish).

15.
Huang, P.C., Wan, S. and Yen, J.Y. (2009), "A novel method of searching appropriate ranges of base isolation design parameters through entropy-based classification", Struct. Control Health. Monit., 16(4), 385-405. crossref(new window)

16.
Jangid, R.S. (2007), "Optimum lead-rubber isolation bearings for near-fault motions", Eng. Struct., 29(10), 2503-2513. crossref(new window)

17.
Kamalzare, M., Johnson, E.A. and Wojtkiewicz, S.F. (2015) "Efficient optimal design of passive structural control applied to isolator design", Smart Struct. Syst., 15(3), 847-862. crossref(new window)

18.
Kasai, K., Mita, A., Kitamura, H., Matsuda, K., Morgan, T.A. and Taylor, A.W. (2013), "Performance of seismic protection technologies during the 2011 Tohoku-Oki Earthquake", Earthq. Spectra, 29(51), 265-293. crossref(new window)

19.
Komodromos, P. (2000), Seismic isolation for earthquake-resistant structures, WIT Press, Southampton, UK.

20.
Liu, T., Zordan, T., Briseghella, B. and Zhang, Q. (2014), "An improved equivalent linear model of seismic isolation system with bilinear behavior", Eng. Struct., 61, 113-126. crossref(new window)

21.
Martelli, A., Clemente, P. and De Stefano, A. (2014b), "How to ensure seismic safety of schools, hospitals, museums and other strategic or public structures if the existing buildings are monumental or simply old", PROHITECH'14, Proceedings of the 2nd International Conference on Protection of Historical Constructions, Bogazici University Publishing, Editores: F.M. Mazzolani & G. Altay, Antalya, Turkey, 7-9 May, pp. 431-437.

22.
Martelli, A., Clemente, P. and Forni, M. (2015), "Worldwide state-of-the-art of development and application of anti-seismic systems based on the information provided at the ASSISi Sendai Conference in 2013 and later and conditions for their correct use", Key-Note lecture, Proceedings of the 14th World Conference on Seismic Isolation, Energy Dissipation and Active Vibration Control of Structures, San Diego, USA, 9-11 September, Book of Abstracts, p. 9.

23.
Martelli, A., Clemente, P., De Stefano, A., Forni, M. and Salvatori, A. (2014a), "Recent development and application of seismic isolation and energy dissipation and conditions for their correct use", Perspectives on European Engineering and Seismology, Editor: Atilla Ansal, Book Series: Geotechnical, Geological and Earthquake Engineering, 1, 449-488, Springer.

24.
Mazza, F. and Vulcano, A. (2012), "Effects of near-fault ground motions on the nonlinear dynamic response of base-isolated r.c. framed buildings", Earthq. Eng. Struct. D., 41(2), 211-232. crossref(new window)

25.
Morgan, T.A. and Mahin, S.A. (2008), "Performance-based design of seismic isolated buildings considering multiple performance objectives," Smart Struct. Syst., 4(5), 655-666. crossref(new window)

26.
Naeim, F. and Kelly, J.M. (1999), Design of seismic isolated structures: From theory to practice, John Wiley & Sons, Inc., USA.

27.
Nagarajaiah, S. and Xiaohong, S. (2000), "Response of base-isolated USC hospital building in Northridge earthquake", J. Struct. Eng. - ASCE, 126(10), 1177-1186. crossref(new window)

28.
Nagarajaiah, S., Reinhorn, A.M. and Constantinou, M.C. (1991), "3D-Basis: Nonlinear dynamic analysis of three-dimensional base isolated structures: Part II," Techical Report NCEER-91-0005, National Center for Earthquake Engineering, State University of New York at Buffalo.

29.
Nigdeli, S.M., Bekdas, G. and Alhan C. (2014), "Optimization of seismic isolation systems via harmony search", Eng. Optim., 46(11), 1553-1569. crossref(new window)

30.
Pan, P., Ye, L., Shi, W. and Cao, H.Y. (2012), "Engineering practice of seismic isolation and energy dissipation structures in China", Sci. China-Technol. Sci., 55(11), 3036-3046. crossref(new window)

31.
Pan, P., Zamfirescu, D., Nakashima, M., Nakayasu, N. and Kashiwa, H. (2005), "Base-isolation design practice in Japan: Introduction to the Post-Kobe approach", J. Earthq. Eng., 9(1), 147-171.

32.
Park Y.J., Wen Y.K. and Ang A.H.S. (1986), "Random vibration of hysteretic systems under bi-directional ground motions", Earthq. Eng. Struct. D., 14(4), 543-557. crossref(new window)

33.
PEER (2005), http://peer.berkeley.edu/smcat/search.html, Peer Strong Motion Databank

34.
Petti, L., Giannattasio, G., De Iuliis, M. and Palazzo, B. (2010), "Small scale experimental testing to verify the effectiveness of the base isolation and tuned massdampers combined control strategy", Smart Struct. Syst., 6(1), 57-72. crossref(new window)

35.
Shenton III, H.W. and Holloway, E.S. (2000), "Effect of stiffness variability on the response of isolated structures", Earthq. Eng. Struct. D., 29(1), 19-36. crossref(new window)

36.
Siringoringo, D. and Fujino, Y. (2015), "Seismic response analyses of an asymmetric base-isolated building during the 2011 Great East Japan (Tohoku) Earthquake", Struct. Control Health Monit., 22(1), 71-90. crossref(new window)

37.
Vassiliou, M.F., Tsiavos, A. and Stojadinovic, B. (2013) "Dynamics of inelastic base-isolated structures subjected to analytical pulse ground motions", Earthq. Eng. Struct. D., 42(14), 2043-2060.