JOURNAL BROWSE
Search
Advanced SearchSearch Tips
GOOSE Traffic Generator Using Network Emulation
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
 Title & Authors
GOOSE Traffic Generator Using Network Emulation
Hwang, Sung-Ho;
  PDF(new window)
 Abstract
IEC 61850 is a protocol used to reduce the cost of design, installation and maintenance of the Substation Automation System. GOOSE traffic used in IEC 61850 plays an important role for control, protection and automation of the substation. This study implemented a GOOSE traffic generator using the emulation function of NS-3 network simulator, by using protocols provided by a network simulator and another protocols provided by real communication equipment. The generated GOOSE traffic was analyzed with Wireshark, and it was found that the traffic was generated exactly as expected. Besides, this study measured the GOOSE traffic delay due to the increase of the number of switches according to network topology. It is expected that the GOOSE traffic generator implemented by this study will be efficiently used when experiments are performed on actual substation environments.
 Keywords
GOOSE;IEC 61850;Network Emulation;
 Language
Korean
 Cited by
 References
1.
IEC 61850-8-1.; Communication networks and systems in substations - Specific Communication Service Mapping (SCSM) Mappings to MMS (ISO 9506-1 and ISO 9506-2) and to ISO/IEC 8802-3, International Electrotechnical Commission (IEC), 2003.

2.
NS-3 Open-Source Network Simulator, version 3.23. [Online]. Available:http://www.nsnam.org. [Accessed: October. 15, 2015].

3.
Wireshark Network Protocol Analyzer, version 2.0.1 [Online]. Available: http://www.wireshark.org. [Accessed: Dec. 15, 2015].

4.
Kee-Min Kim, et al 4, "Wireless Sensor Network based Remote Power Monitoring System for Anti Islanding application in Smart-Grid", The Journal of The Institute of Internet, Broadcasting and Communication (JIIBC), vol. 10, no. 4, pp. 57-62, 2010. 8.

5.
Sunny Ro, et al 4, "Development of a Smart Grid Monitoring System with Anti-Islanding Function for Electric Vehicle Charging", The Journal of The Institute of Internet, Broadcasting and Communication(JIIBC), vol. 12, no. 5, pp. 31-37, 2012. 10. DOI: http://dx.doi.org/10.7236/JIWIT. 2012.12.5.31 crossref(new window)

6.
Sami S. et al 3, "Performance analysis of Centralized, Distributed and Hybrid Demand Load Control architecture for Smart power Grid" Journal of the Korea Academia-Industrial cooperation Society (JKAIS), Smart Computing Review, vol. 2, no. 5, pp. 370-378, 2012. 10. DOI: http://dx.doi.org/10.6029/smartcr.2012.05.007 crossref(new window)