3D CACT-assisted Radiofrequency Ablation Following Transarterial Chemoembolization for Hepatocellular Carcinoma: Early Experience
Jiao, De-Chao; Han, Xin-Wei; Wu, Gang; Ren, Jian-Zhuang;
  PDF(new window)
 Abstract
Background: To explored the value of 3D C-arm CT (CACT) guidance system in performing radiofrequency ablation (RFA) following transarterial chemoembolizationon (TACE) for hepatocellular carcinomas. Materials and Methods: RFA of hepatocellular carcinomas (HCC) were performed on 15 patients (21 lesions) with the assistance of CACT guidance system. Technical success, procedure time, complications and patient radiation exposure were investigated. The puncture performance level was evaluated on a five-point scale (5-1: excellent-poor). Complete ablation rate was evaluated after two months follow-up using enhanced CT scans. Results: The technical success rate of RFA procedure under CACT navigation system was 100 %. Mean total procedure time was , resulting in a mean effective exposure dose of . The mean puncture performance level rated for CACT guided RFA procedure was . Complete ablation (CA) was achieved in 20 (95.2%) of the treated 21 tumors after the first RFA session. None of patients developed intra-procedural complications. Conclusions: 3D CACT guidance system enables reliable and efficient needle positioning by providing real-time intraoperative guidance for performing RFA on HCCs.
 Keywords
Flat detector C;arm CT;Hepatocellular carcinoma;Interventional radiology;radiofrequency ablation;
 Language
English
 Cited by
1.
Flat detector cone beam CT-guided nephrostomy using virtual navigation in patients with iatrogenic ureteral injury, La radiologia medica, 2017, 122, 8, 557  crossref(new windwow)
 References
1.
Ahmed M, Brace CL, Lee FT, et al (2011). Principles of and advances in percutaneous ablation. Radiology, 258, 351-9. crossref(new window)

2.
Bapst B,Lagadec M, Breguet R, et al (2015). Cone Beam Computed Tomography (CBCT) in the Field of Interventional Oncology of the Liver. Cardiovasc Intervent Radiol.

3.
Braak SJ, van Strijen MJ, van Es HW, et al (2011). Effective dose during needle interventions: cone-beam CT guidance compared with conventional CT guidance. J Vasc Interv Radiol, 22, 455-61. crossref(new window)

4.
Busser WM, Braak SJ, Futterer JJ, et al (2013). Cone beam CT guidance provides superior accuracy for complex needle paths compared with CT guidance. Br J Radiol, 86, 20130310. crossref(new window)

5.
Cazzato RL, Buy X, Alberti N, et al (2015). Flat-panel conebeam CT-guided radiofrequency ablation of very small ($\leq$ 1.5 cm) liver tumors: technical note on a preliminary experience. Cardiovasc Interv Radiol, 38, 206-12. crossref(new window)

6.
Cha D, Lee MW, Rhim H, et al (2013). Therapeutic efficacy and safety of percutaneous ethanol injection with or without combined radiofrequency ablation for hepatocellular carcinomas in high risk locations. Korean J Radiol, 14, 240-7. crossref(new window)

7.
Cheung JY, Kim Y, Shim SS, et al (2011). Combined fluoroscopyand CT-guided transthoracic needle biopsy using a C-arm cone-beam CT system: comparison with fluoroscopy-guided biopsy. Korean J Radiol, 12, 89-96. crossref(new window)

8.
Chiara F, Alessandra M, Federico F, et al (2014). C-arm cone-beam computed tomography needle path overlay for percutaneous biopsy of pulmonary nodules. Radiol Med, 19, 820-7.

9.
Cho YK, Rhim H, Noh S (2011). Radiofrequency ablation versus surgical resection as primary treatment of hepatocellular carcinoma meeting the Milan criteria: a systematic review. J Gastroenterol Hepatol, 26, 1354-60.

10.
Grasso RF, Cazzato RL, Luppi G, et al (2013). Percutaneous lung biopsies: performance of an optical CT-based navigation system with a low-dose protocol. Eur Radiol, 23, 3071-6. crossref(new window)

11.
Gupta R, Cheung AC, Bartling SH, et al (2008). Flat-panel volume CT: fundamental principles, technology, and applications. Radiographics, 28, 2009-22. crossref(new window)

12.
Hakime A, Deschamps F, De Carvalho EG, et al (2012). Electromagnetic-tracked biopsy under ultrasound guidance: preliminary results. Cardiovasc Intervent Radiol, 35, 898-905. crossref(new window)

13.
Hol PK (2007). Ablative therapy of liver tumors. Acta Radiol, 48, 473. crossref(new window)

14.
Jiao D, Qian L, Zhang Y, et al (2010). Microwave ablation treatment of liver cancer with 2,450-MHz cooled-shaft antenna: an experimental and clinical study. J Cancer Res Clin Oncol, 136, 1507-16. crossref(new window)

15.
Jiao de C, Li TF, Han XW, et al (2014). Clinical applications of the C-arm cone-beam CT-based 3D needle guidance system in performing percutaneous transthoracic needle biopsy of pulmonary lesions. Diagn Interv Radiol, 20, 470-4. crossref(new window)

16.
Kalender WA, Kyriakou Y (2017). Flat-detector computed tomography (FD-CT). Eur Radiol, 17, 2767-79.

17.
Lee IJ, Chung JW, Yin YH, et al (2014). Cone-beam CT hepatic arteriography in chemoembolization for hepatocellular carcinoma: angiographic image quality and its determining factors. J Vasc Interv Radiol, 25, 1369-79. crossref(new window)

18.
Lee JY, Choi BI, Chung YE, et al (2012). Clinical value of CT/MR-US fusion imaging for radiofrequency ablation of hepatic nodules. Eur J Radiol, 81, 2281-9. crossref(new window)

19.
Mettler FA Jr, Huda W, Yoshizumi TT, et al (2008). Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology, 248, 254-63. crossref(new window)

20.
Morimoto M, Numata K, Kondo M, et al (2010). C-arm cone beam CT for hepatic tumor ablation under real-time 3D imaging. Am J Roentgenol, 194, 452-4. crossref(new window)

21.
Park BK, Kim CK (2009). Complete ablation of a renal tumor abutting the inferior vena cava using a radiofrequency electrode as a lever: a case report. Acta Radiol, 50, 238-240. crossref(new window)

22.
Racadio JM, Babic D, Homan R, et al (2007). Live 3D guidance in the interventional radiology suite. Am J Roentgenol, 189, 357-64. crossref(new window)

23.
Rotolo N, Floridi C, Imperatori A, et al (2015). Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules. Eur Radiol, 2015.

24.
Schegerer AA, Lechel U, Ritter M, et al (2014). Dose and image quality of cone-beam computed tomography as compared with conventional multislice computed tomography in abdominal imaging. Invest Radiol, 49, 675-84. crossref(new window)

25.
Sun YX, Cheng W, Han X, et al (2014). In vivo experimental study on the effects of fluid in increasing the efficiency of radiofrequency ablation. Asian Pac J Cancer Prev, 15, 5799-804. crossref(new window)

26.
Wang CH, Wey KC, Mo LR, et al (2015). Current trends and recent advances in diagnosis, therapy, and prevention of hepatocellular carcinoma. Asian Pac J Cancer Prev, 16, 3595-604. crossref(new window)

27.
Wang ZJ, Wang MQ, Duan Feng, et al (2013). Clinical application of transcatheter arterial chemoembolization combined with synchronous C-arm Cone-Beam CT guided radiofrequency ablation in treatment of large hepatocellular Carcinoma. Asian Pacific J Cancer Prev, 14, 1649-54. crossref(new window)

28.
Xu C, Lv PH, Huang XE, et al (2015). Efficacy of transarterial chemoembolization combined with radiofrequency ablation in treatment of hepatocellular carcinoma. Asian Pac J Cancer Prev, 16, 6159-62. crossref(new window)