In this study, to investigate the feasibility of malodorous substance and organic matter removal by digest sludge in sewage treatment plants, ammonia, methyl mercaptan(MMC), and hydrogen sulfide() in a reactor submerged with BIO-CLOD(BIO-CLOD) and a reactor not submerged with BIO-CLOD(Non BIO-CLOD) were measured at 24 hours, 48 hours, and 72 hours after the submergence of BIO-CLOD. Whereas the reactor in which BIO-CLOD was submerged showed an ammonia removal rate of 48% and high and MMC removal rates exceeding 98% in 24 hours, the reactor in which BIO-CLOD was not submerged showed an ammonia removal rate of 45%, an removal rate of 71%, and an MMC removal rate of 84% in 24 hours indicating the possibility of removal of malodor using BIO-CLOD. A nitrification was shown in which ammonia concentrations decreased over time while nitrate nitrogen concentrations increased and sulfur based malodor components were oxidation decomposed indicating that BIO-CLOD had effects to increase sulfate concentrations in the solution and that sulfate concentration increases and atmospheric removal rates were correlated with each other. With regard to decreases in organic matter in reactor effluents, BIO-CLOD did not affect in a short period of time and when reactors were operated with HRT 12 hours and HRT 24 hours, HRT 12 hours was considered desirable in terms of economy.
BIO-CLOD;digested sludge;;odor removal;
 Cited by
Ministry of Environment, Malodor prevention act, 2014. 9. 25

Chen L., Hoff S., Cai L.,Koziel J., Zelle B.,"Evaluation of wood chip-based biofilters to reduce odor, hydrogen sulfide, and ammonia from swine barn", J. Air & Waste Manege. Assoc., 59(5), pp. 520-530, 2009. DOI: crossref(new window)

Lee T.J., Kweon O. Y., An S. J., " Removal of odor causing compounds using adsorption of crushed refuse-tire and phenol oxidizing bacteria, cryptoccus terreus A",J. of Korean Soc of Environ Eng, 22(9), pp.1601-1607, 2000.

Ko B. C., Park Y. H., Kim D. I., Lee M. G., Kam S. K., "Odor removal characteristics of biofilters in domestic sewage treatment facilities analyzing composite odor and odor quotient" J. of the Environ Scienses , 22(1), pp. 109-117, 2013. DOI: crossref(new window)

Park W.C., Lee M.A., Sung I.W., "Nutrient removal in an advanced treatment process using the BIO-CLOD". J. of Environ Health Science, 40(4), pp.1-8, 2014. DOI: crossref(new window)

Jung B. G., Seong D. H., Bin J. I., Lee B. H., "Removal of odorfrom food wastes by nightsoil treatment sludge including Bacillus", J. of Water Treatment, 22(5), pp.49-58, 2014.

APHA, AWWA, WEF, Standard Methods for the Examination of Water and Wastewater, 21th Ed., Washington DC, AHPA Pub., 2005 p.5-18.

Kim J. W., Sekyama K., Lee D. W., KIm H. O., "Odors from wastewater treatment plants", Korean Journal of Odor Research and Engineering, 5(3), pp.180-192, 2006.

Huh M., Park C. K., "Odor control for the nightsoil treatment plant by a biological submerged deodorator with air lift aeration", J. of Korean Soc of Environ Eng, 11(1), pp. 1-11, 1989.

Choi I., Lee H. J., Shin J. D., Kim H. O., "Evaluation of effectiveness of five odor reducing agents for sewer system osors using an on-line total reduced sulfur analyzer", Sensors, 12, pp. 16892-16906, 2012. crossref(new window)

Jeon J. M., Seo Y. S., Jeong M. H., Lee H. S., Lee M. D., Han J. S., Kang B. W.," The emission characteristics of odor compounds from environment fundamental facilities", Korean Journal of Odor Research and Engineering, 9(2), pp. 80-89, 2010. DOI: