Present Status of Soil Contamination Facilities
facebook(new window)  Pirnt(new window) E-mail(new window) Excel Download
 Title & Authors
Present Status of Soil Contamination Facilities
Kim, Ki-Ho; Park, Jae-Soo; Kim, Hae-Keum; Choi, Sang-Il;
  PDF(new window)
 Abstract
This study was to build the database by collecting the results of legal leak test and self-test conducted by the owners of soil contamination facilities at soil-related specialized agency to grip objective status on soil contamination facilities and evaluate classification results. The results of the study showed that the unsuitable rate of business unit is 53.6%, the business with leak that could cause actual pollution is 25.7%, the unsuitable rate of the voluntary self-test is 57.3%, that of the compulsory inspection is 17.2% depending on the test motivation, that of the direct-test is 58.9%, and that of the indirect-test is 22.5% depending on the test methods. There was a significant difference between the test motivation conducted and the test methods applied. From the results of the unsuitable reasons obtained we could assume that about 20% of the whole target tanks became potential sources with natural defects occurred when such tanks were made, and 2.2% of the whole tankers examined that persisting period was caused by progressing corrosion below the minimum thickness.
 Keywords
Leak test;Oil storage tank;Soil contamination facilities;
 Language
Korean
 Cited by
 References
1.
Bae, W.K., J.C. Hong, W.J. Kang, and J.W. Chung, 1999. Prevention of soil contamination from underground storage facilities. Bulletin of Environmental Science, Vol. 20, 1999, EERI. Hanyang Univ.

2.
Choi, M.J. 2006. The characterization and management of leaking underground storage tank in gas station. Univ. of Seoul.

3.
Fleischer, D.W. 1993. Error sources in automatic tank gauging system. ASTM. Leak detection for underground storage tanks, pp. 17-29.

4.
Jeong, C.W. 2010. A study on interference of the stray current induced by electric railways on adjacent buried pipelines. SNU of S. and T.

5.
Jeong, J.S. 2000. A study of soil contamination sources and countermeasures in gas Station. Thesis. Yonsei Univ.

6.
Kim, B.R. 2003. An empirical study on safety management underground hazardous facilities. Thesis. Univ. of Seoul

7.
Kim, M.J. 2003. Plants of management reinforcement for underground storage tank. KIPE.

8.
Park, J.S. 2003. Comparison of leak testing methods for underground storage tanks. Hanyang Univ.

9.
Yoon, T.G. and S. Lee. 2006. A case study on the method to improve on the structure of oil tank. KSMI, Book 10 Vol. 2, pp. 185-190.