An Experimental Study on Measurement of the Reaction Order of a Liquid Fuel with Various Components

혼합 액체연료의 화학반응차수 계측에 관한 실험적 연구

  • 최효현 (세종대학교 대학원 기계공학과) ;
  • 임준석 (세종대학교 대학원 기계공학과) ;
  • 김철진 (세종대학교 대학원 기계공학과) ;
  • 손채훈 (세종대학교 기계항공우주공학부)
  • Published : 2011.04.28

Abstract

Thermal Analyses are conducted to measure various factors of a liquid fuel required for numerical analysis. Thermal Analyses are divided into two different methods of TGA (Thermo Gravimetric Analysis) and DSC (Differential Scanning Calorimetry). Non-isothermal experimental results are analyzed using by TGA. The results are filtered by a Freeman Carroll method. At the same time, chemical parameters of unknown liquid fuel, activation temperature and reaction order are measured to 6128.2 K and 1.4, respectively. Furthermore, the parameters can be obtained by various mathematical methods. It is found that tha parameters depend on the processing method.