Korean Journal of Materials Research (한국재료학회지)
- Volume 5 Issue 7
- /
- Pages.842-849
- /
- 1995
- /
- 1225-0562(pISSN)
- /
- 2287-7258(eISSN)
Abstract
The effect of cathodic protection by the sacrificial anode attached to condenser waterbox of power plant was investigated using numerical analysis. The condenser is consisted of various materials. So in case of no protection, the serious galvanic corrosion between waterbox and tubesheet was observed. If sacrificial anodes were attached to the wall of waterbox or the area corroded galvanically, the large protection effect was showed. To demonstrate the validity of numerical analysis results, model test was executed. The numerical solution was consistent with the experimental vague well.
Keywords
File
References
- Electrochim. Acta. v.9 J.A. Klingert;S. Lynn;C.W. Tobias
- Corrosion v.1 G. Prentice;R.A. Holser;V.J. Farozic;R.B. Pond,Jr;K.L. Cramblitt
- 火力原子力發展 v.11 S. Ingaki;S. Wado;N. Kikuna;S. Shiode;T. Sasamoro;M. Miyazaki;Y. Nishino
- 火力原子力發展 v.4 S. Inagaki;N. Kikuna;T. Satou;Y. Nishino;M. Miyazaki
- Computer Modeling in Corrosion R.A. Adey;s.M. Niku
- Computer Modeling in Corrosion K.R. Trethewey;J.S. Keenan
- Electrical Engineering Applications v.7 Topics in Boundary Element Research C.A. Brebbia
- 中間報告書 Studies on the Current and Potential Distributions of Cathodic Protection Systems 韓國電氣硏究所
- 復水器工學 handbook 川邊允志;荒木道郞;藤井哲;靑水潮