Abstract

This study provides comprehensive design improvements covering technical issues concerning life safety matter In case of fire train stoppage in the middle of a tunnel. Recently Government announced that most of subway platforms will have screen doors in 3 years. Therefore, many fire safety engineers considered that they may contribute on life safety on train stoppage in tunnel. Especially The screen door can protect platform from smoke along tunnel ceiling when fire train stopped in tunnel. The study showed that platform ventilation ducts and the a tunnel ventilation chimney in the middle of tunnel in exiting subway tunnel could not guarantee life safety ability in terms of RSET vs. ASET comparison. Furthermore during evacuation process many peoples may be threatened from the smoke spread from the origin of fire. Although only additional vertical route can be installed in tunnels In order to decrease RSET, it will costs high or no spaces remains in outside on the road. The study suggested that increase of ASET can be best solution without additional escape route, therefore alternative design methods suggested on the base of simulation results. Finally the study shows alternative methods can give good result in terms of evacuation performance evaluation. The evacuation performance evaluation helps the decision-maker to determine the preferred alternatives or upgrades to existing tunnel infrastructure and other measure to meet safety objectives. Finally, the study details the effectiveness of measures the can be taken to reduce the risk of incidents in subway tunnels.

References

  1. Geoff Cox and Suresh Kumar, 'Modeling Enclosure Fires Using CFD', The SFPE Handbook of Fire Protection Engineering, Third Edition, 2002
  2. 박형주, 서울특별시 도시철도공사, '도시철도공사 고심도 및 환승역의 화재영향평가', 2005. 12
  3. John H. Klote, 'Design Manual For Smoke Control Systems', 1991.10
  4. Klaus Kruse, 'Fire And Disaster Control', Deutsche Bahn AG, 2002.12
  5. Ronald Barham, 'Fire Engineering and Emergency Planning, E&FN SPON, 1995