Dynamic Characteristic of A Bi-dirctional Damper Using A Tuned Mass Damper and A Tuned Liquid Column Damper

TMD와 TLCD를 이용한 2방향 감쇠기의 동적특성

  • Published : 2008.12.30

Abstract

This study introduces the design of a bi-directional damper using a tuned mass damper(TMD) and a tuned liquid column damper(TLCD) and presents experimental verifications to confirm its control performance. The damper used in this study behaves as a TMD in a specific translational direction and acts as a TLCD in the other orthogonal direction. First, shaking table test is performed to investigate the coupled effect of control forces produced by TMD and TLCD. Then, the parameters that affect to dynamic characteristics of the proposed damper are quantitatively evaluated based on the experimental results. Testing results shows that the damper used in this study produces control forces coupled by TLCD and TMD, as it is excited by waves with an incident angle. Also, it is observed that the damper can be used to reduce bi-directional responses of building structures.

References

  1. 허재성, 박은천, 이성경, 이상현, 김홍진, 조지성, 조봉호, 주석준, 민경원 (2008c) 실물크기 구조물에 설치된 동조액 체질량감쇠기의 성능실험, 한국전산구조공학회 논문집, 21(2), pp.161-168
  2. Den Hartog, J. P. (1956) Mechanical vibrations, McGraw-Hill
  3. Soong, T. T., Dargush, G. F. (1997) Passive Energy Dissipation Systems in Structural Enginnering, John Wiley & Sons
  4. Hitchcock, P. A., Kwok, K. C. S., Watkins, R. D. (1997b) Characteristics of liquid column vibration absorbers (LCVA)- II, Engineering Structures, 19(2), pp.135-144 https://doi.org/10.1016/S0141-0296(96)00044-2
  5. Zhang, X. T., Zhang, R. C., Xu, Y. L. (1993a) Analysis on control of flow-induced vibration by tuned liquid damper with crossed tube-like containers, Journal of Wind Engineering and Industrial Aerodynamics, 50, pp.351-360 https://doi.org/10.1016/0167-6105(93)90090-B
  6. Desu, N. B., Deb, S. K., Dutta, A. (2006) Coupled tuned mass dampers for control of coupled vibrations in asymmetric buildings. Struct. Control Health Monit., 13, pp.897-916 https://doi.org/10.1002/stc.64
  7. Reiterer, M., Ziegler, F. (2005) Bi-axial seismic activation of civil engineering structures equipped with tuned liquid column dampers, JSEE: Spring, 7(1), pp.45-60
  8. Xu, Y. L., Samali, B., Kwok, K. C. S. (1992) Control of along-wind response of structures by mass and liquid dampers, Journal of Engineering Mechanics, 118(1), pp.20-39 https://doi.org/10.1061/(ASCE)0733-9399(1992)118:1(20)
  9. Yalla, S. K., Kareem, A. (2000) Optimum absorber parameters for tuned liquid column dampers, Journal of Structural Engineering, 126(8), pp.906-915 https://doi.org/10.1061/(ASCE)0733-9445(2000)126:8(906)
  10. Gao, H., Kwok, K. C. S. (1997) Optimization of tuned liquid column dampers, Engineering Structures, 19(6), pp.476-486 https://doi.org/10.1016/S0141-0296(96)00099-5
  11. Ueng, J. M., Lin, C. C., Wang, J. F. (2008) Practical design issues of tuned mass dampers for torsionally coupled buildings under earthquake loadings, Struct. Design Tall Spec. Build., 17, pp.133-165 https://doi.org/10.1002/tal.336
  12. Hitchcock, P. A., Kwok, K C. S., Watkins, R. D. (1997a) Characteristics of liquid column vibration absorbers (LCVA)-I, Engineering Structures, 19(2), pp.126-134 https://doi.org/10.1016/S0141-0296(96)00042-9
  13. Sakai, F., Takaeda, S., Tamaki, T. (1989) Tuned Liquid Column Damper - New Type Device for Suppression of Building Vibrations, Proc. Int. ConI. on Higbrise Buildings, Nanjing. China, pp.926-931
  14. 허재성, 박은천, 이상현, 이성경, 김홍진, 조봉호, 조지성, 김동영, 민경원 (2008a) 건축구조물의 2방향 진동제어를 위한 동조액체질량감쇠기, 한국소음진동공학회 논문집, 18(3), pp.345-355 https://doi.org/10.5050/KSNVN.2008.18.3.345
  15. 허재성, 이성경, 박은천, 이상현, 김홍진, 조지성, 조봉호, 민경원 (2008b) 실시간 하이브리드 진동대 실험법에 의한 양방향 TLMD의 진동제어 성능평가, 한국소음진동공학회 논문집, 18(5), pp.485-495 https://doi.org/10.5050/KSNVN.2008.18.5.485
  16. Shum, K. M. (2008) Closed form optimal solution of a tuned liquid column damper for supressing harmonic vibration of structures, Engineering Structures, doi:10.1016/j.engstruct. 2008.07. 015, in press
  17. Almazan, J. L., Llera, J. C., Inaudi, J. A., Garcia, D. L., Izquierdo, L. E. (2007) A bidirectional and homogeneous tuned mass damper: A new device for passive control of vibrations. Engineering Structures. 29. pp.1548-1560 https://doi.org/10.1016/j.engstruct.2006.09.005
  18. Zhang, X. T., Zhang, R. C. (1993b) On control of along-wind and across-wind vibrations of structure by crossed dampers, Proc. Third Asia-Pacific Symp. on Wind Engineering, Hong Kong, 2, pp.859-864