DOI QR코드

DOI QR Code

Ottonello Projection Techniques using the Metronome

메트로놈을 이용한 Ottonello 촬영 기법

  • 임인철 (가야대학교 방사선학과) ;
  • 김창수 (부산가톨릭대학교 보건과학대학 방사선학과)
  • Published : 2009.12.28

Abstract

The ottonello method is used to see a front view image of cervical 1-7 number. The study found a systematic examination method to find a better image through an experiment using metronome. The results are as follows: In an evaluation of MTF, when used 0.5 standard of MTF, oral explanation resulted 1.2 LP/mm, Moderato-100 1.4 LP/mm, Allegro-138 1.6 LP/mm, Presto-184 2.4 LP/mm. Among them presto-184 showed the highest sharpness with 2.4 LP/mm. In an image reading by a medicine doctor of radiology, when oral explanation was 17%, Moderato-100 15%, Allegro-138 18%, Presto-184 50%. Among themprest-184 was evaluated as the best image. The result of was a method to reduce an image repeat, patients radiation exposure, patients waiting time for examination, material and so on.

Keywords

Ottonello;Metronome;MTF(Modulation Transfer Function);Repeat

References

  1. 김현수, 김화선, 문희석, 방사선영상학, 대학서림, p.296, 2008.
  2. http://100.naver.com/100.nhn?docid=61739
  3. http://jnjmuse.cnei.or.kr/theory006_low.htm
  4. 김영근, 김영일, 김화곤, 의료영상정보학 실험, 신광출판사, p.344, 2007.
  5. 권덕문, 김성수, 김영근, 의료영상정보학, 대학서림, p.173, 2008.
  6. 강세식, 고성진, 고인호, TEXTBOOK of Radiographic Positioning and Clinical Diagnosis(2nd Edition), 청구문화사, p.236, 2004.
  7. 의료영상정보연구회, 의료영상정보학, 청구문화사, pp.161-174, 2008.
  8. Jerry L. Prince, Jonathan M. Links, Medical Imaging Signals and Systems, Prentice-hall, pp.63-101, 2006.
  9. L. Yves, C. Alessandra, and R. Ghita, Physics for Medical Imaging Applications, pp.3-22, 2007.