Detection of chlorine in tap water using a metal gold electrode

금속 Au 전극을 이용한 먹는 물 속 염소 이온 검출

  • Received : 2011.04.04
  • Accepted : 2011.05.12
  • Published : 2011.06.25

Abstract

Voltammetric analysis of Cl(I) ion was performed using a metal gold (Au) electrode (AE) and a carbon nanotube electrode (CNTE). After the examination, the AE was found to have more sensitively detected Cl(I) than CNTE. The optimum analytical conditions for the cyclic voltammetry (CV) and the square wave (SW) stripping voltammetry were performed using AE. The detection limit of $6.5\;{\mu}g/L$ Cl(I) was attained. The developed techniques were compared with the common Cl meter and applied to water systems.

Keywords

Cl;Tap water;voltammetry;detection

References

  1. X. Liang, F. Liu, T. Zhong, B. Wang, B. Quan and G. Lu. Solid. State. Ionics., 179, 1636 (2008). https://doi.org/10.1016/j.ssi.2008.01.004
  2. L. Trnkova, V. Adam, J. Hubalek, P. Babula and R. Kizek, Sensors 2008, 8, 5619 (2008).
  3. X. A. Li, D. M. Zhou, J. J. Xu and H. Y. Chen, Talanta, 75, 157 (2008). https://doi.org/10.1016/j.talanta.2007.10.054
  4. H. S. Shin and D. G. Jung, J. Chromatogr. A, 1123, 92 (2006). https://doi.org/10.1016/j.chroma.2006.04.089
  5. G. Jin, J. Yang and J. F. Li, Microchim. Acta, 148, 171 (2004). https://doi.org/10.1007/s00604-004-0255-x
  6. Z. X. Gao, H. F. Li, J. Liu and J. M. Lin, Anal. Chim. Acta, 622, 143 (2008). https://doi.org/10.1016/j.aca.2008.05.067
  7. E. V. Polyakova and O. V. Shuvaeva, J. Anal. Chem., 63, 391 (2008). https://doi.org/10.1134/S106193480804014X
  8. J. E. Presta, M. S. Beardahb, S. J. Baldocka, S. P. Doyleb, P. R. Fieldena, N. J. Goddarda and B. J. T. Browna, J. Chromatogr. A, 1195, 157 (2008). https://doi.org/10.1016/j.chroma.2008.05.013
  9. T. V. Belysheva and L. P. Bogovtseva, J. Anal Chem., 61, 494 (2006). https://doi.org/10.1134/S106193480605011X
  10. B. Saad, W. T. Wai, S. Jab, W. S. W. Ngah, M. I. Saleh and J. M. Slater, Anal. Chim. Acta, 537, 197 (2005). https://doi.org/10.1016/j.aca.2005.01.002
  11. G. Pezzatini, I. Midili, G. T. F. Loglio and M. Innocenti, Anal. Bioanal. Chem., 380, 650 (2004). https://doi.org/10.1007/s00216-004-2732-9
  12. G. Sun, S. Liu, K. Hua, X. Lv, L. Huang and Y. Wang, Electrochem. Commun., 9, 2436 (2007). https://doi.org/10.1016/j.elecom.2007.07.015
  13. A. Fanigliulo and B. Bozzini, Electrochim Acta 47, 4511 (2002). https://doi.org/10.1016/S0013-4686(02)00538-8
  14. Y. Bonfil, M. Brand and E. Kirowa-Eisner, Anal. Chim. Acta, 464, 99 (2002). https://doi.org/10.1016/S0003-2670(02)00489-0
  15. L. Baldrianova, I. Svancara, M. Vlcek, A. Economouc and S. Sotiropoulos, Electrochim. Acta, 52, 481 (2006). https://doi.org/10.1016/j.electacta.2006.05.029
  16. G. Carpini, F. Lucarelli, G. Marrazza and M. Mascini, Biosens Bioelectron., 20, 167 (2004). https://doi.org/10.1016/j.bios.2004.02.021