Abstract

Purpose: To evaluate the changes of OSI value according to tear-film instability measured serially by OQAS(Optical Quality Analysis System, Visiometrics, Spain) every seconds. The presented study analyzed the relationship of the OQAS parameter with the results of the tear-film break-up time, Schirmer test, and the McMonies score. Methods: 147 eyes of 82 subjects were randomly selected from university students (age: $21.51{\pm}3.97$, male 45, female 37). Subjects were measured tear-film break-up time, Schirmer test, McMonies score and once every second for 15 seconds after blinking by continuous measurements from OQAS system. Results: The normal eye groups presented OSI values of $2.13{\pm}1.16$ while the dry eye groups had OSI values of $3.76{\pm}1.42$. Therefore, a significant difference between the normal eye group and dry eye group was discovered (p<0.05). In addition, the OSI value of all subjects increased over time. The OSI value, which was measured every second after blinking occurred, significantly increased between 6 seconds and 7 seconds after the start of the measurement (p<0.05). OSI cut off of 30% (sec.) showed a greater correlation; TBUT (r = 0.855, p = 0.000), McMonies test (r = -0.351, p = 0.003), Schirmer (r = 0.316, p = 0.012). Conclusions: Continuous measurement of OQAS showed a high correlation with the value of the existing dry eye tests. Therefore, Analysis of OSI values by utilization of OQAS could be useful in objectively evaluation of tear film in patients.

Keywords

OSI;Dry eye;TBUT;McMonnies test;Schirmer test

References

  1. Kim JS, Shin JA, Lee OJ. Ocular anatomy, 1st Ed. Seoul: Chungkumunhwasa, 2005;240-243.
  2. Albarrn C, Pons AM, Lorente A, Montes R, Artigas JM. Influence of the tear film on optical quality of the eye. Contact Lens Anterior Eye. 1997;20(4):129-135. https://doi.org/10.1016/S1367-0484(97)80011-2
  3. The definition and classification of dry eye disease: Report of the Definition and Classification Subcommittee of the International Dry Eye Workshop(2007). Ocul Surf. 2007;5(2):75-92. https://doi.org/10.1016/S1542-0124(12)70081-2
  4. Pflugfelder SC, Tseng SC, Sanabria O, Kell H, Garcia CG, Felix C et al. Evaluation of subjective assessments and objective diagnostic tests for diagnosing tear-film disorders known to cause ocular irritation. Cornea. 1998;17(1):38-56. https://doi.org/10.1097/00003226-199801000-00007
  5. Byun YS, Jeon EJ, Chung SK. Clinical effect of cyclosporine 0.05% eye drops in dry eye syndrome patients. J Korean Ophthalmol Soc. 2008;49(10):1583-1588. https://doi.org/10.3341/jkos.2008.49.10.1583
  6. Begley CG, Caffery B, Nichols K, Mitchell GL, Chalmers R. Results of a dry eye questionnarire from optometric practices in North America. Adv Exp Med Biol. 2002; 506(Pt B):1009-1016. https://doi.org/10.1007/978-1-4615-0717-8_40
  7. Thomson WD. Eye problems and visual display terminals-the facts and the fallacies. Ophthalmic Physiol Opt. 1998;18(2):111-119. https://doi.org/10.1016/S0275-5408(97)00067-7
  8. Mah KC, Park M., Kim HJ, Kim DP, Back SS, Eom JH. Contact lens complications, 1st Ed. Seoul: Elsevier Korea L.L.C, 2008;54-69.
  9. Chung SH, Na KS, Kwon HG, Lee HS, Kim SY, Kim EC. Levels of severity in dry eye syndrome according to Delphi panel classification. J Korean Ophthalmol Soc. 2010; 51(9): 1179-1183. https://doi.org/10.3341/jkos.2010.51.9.1179
  10. Moss SE, Klein R, Klein BE. Incidence of dry eye in an older population. Arch Ophthalmol. 2004;122(3):369-373. https://doi.org/10.1001/archopht.122.3.369
  11. Health Insurance Review & Assessment Service : Dry eye syndrome. It can still occur during spring and summer, 2014. http://www.hira.or.kr/dummy.do?pgmid=HIRAA020041000000&cmsurl=/cms/notice/02/1324964_24959.html&subject= (5 April 2015).
  12. Paschides CA, Kitsios G, Karakostas KX, Psillas C, Moutsopoulos HM. Evaluation of tear break-up time, Schirmer's-I test and rose bengal staining as confirmatory tests for keratoconjunctivitis sicca. Clin Exp Rheumatol. 1989;7(2):155-157.
  13. Morgan PB, Tullo AB, Efron N. Infrared thermography of the tear film in dry eye. Eye(Lond). 1985;9(Pt5):615-618.
  14. Benito A, Prez GM, Mirabet S, Vilaseca M, Pujol J, Marn JM et al. Objective optical assessment of tear-film quality dynamics in normal and mildly symptomatic dry eyes. J Cataract Refract Surg. 2011;37(8):1481-1487. https://doi.org/10.1016/j.jcrs.2011.03.036
  15. Thibos LN, Hong X. Clinical applications of the Shack-Hartmann aberrometer. Optom Vis Sci. 1999;76(12):817-825. https://doi.org/10.1097/00006324-199912000-00016
  16. Koh S, Maeda N, Kuroda T, Hori Y, Watanabe H, Fujikado T et al. Effect of tear film break-up on higher-order aberrations measured with wavefront sensor. Am J Ophthalmol. 2002;134(1):115-117. https://doi.org/10.1016/S0002-9394(02)01430-7
  17. Maeda N. Clinical applications of wavefront aberrometry - a review. Clin Experiment Ophthalmol. 2009;37(1):118-129. https://doi.org/10.1111/j.1442-9071.2009.02005.x
  18. Choi SH, Shin YI. Changes in higher order aberration according to tear-film instability analyzed by continuous measurement using wavefront. J Korean Ophthalmol Soc. 2012;53(8):1076-1080. https://doi.org/10.3341/jkos.2012.53.8.1076
  19. Park CW, Lee YE, Joo CK. Changes in optical quality of cataract patients' corrected visual acuity before and after phacoemulsification. J Korean Ophthalmol Soc. 2013; 54(8): 1208-1212. https://doi.org/10.3341/jkos.2013.54.8.1208
  20. Park CW, Kim GY, Kim HJ, Hwang JH, Joo CK. Objective clinical evaluation of ocular optical instrument according to the type of lens opacity. J Korean Ophthalmol Soc. 2014; 55(1):79-84. https://doi.org/10.3341/jkos.2014.55.1.79
  21. Artal P, Benito A, Prez GM, Alcn E, De Casas A, Pujol J et al. An objective scatter index based on double-pass retinal images of a point source to classify cataracts. PLOS One. 2011;6(2):e16823. https://doi.org/10.1371/journal.pone.0016823
  22. Calonge M, Diebold Y, Sez V, Enrquez de Salamanca A, Garca-Vzquez C, Corrales RM et al. Impression cytology of the ocular surface: a review. Exp Eye Res. 2004; 78(3):457-472. https://doi.org/10.1016/j.exer.2003.09.009
  23. Jung NY, Baek JW, Shin SJ, Chung SK. Tear meniscus evaluation using optical coherence tomography in dry eye patients. J Korean Ophthalmol Soc. 2015;56(3): 323-330. https://doi.org/10.3341/jkos.2015.56.3.323
  24. Simpson TL, Situ P, Jones LW, Fonn D. Dry eye symptoms assessed by four questionnaires. Optom Vis Sci. 2008;85(8):692-699. https://doi.org/10.1097/OPX.0b013e318181ae36
  25. Begley CG, Caffery B, Chalmers RL, Mitchell GL. Use of the dry eye questionnaire to measure symptoms of ocular irritation in patients with aqueous tear deficient dry eye. Cornea. 2002;21(7):664-670. https://doi.org/10.1097/00003226-200210000-00007
  26. Hamano H, Hori M, Hamano T, Mitsunaga S, Maeshima J, Kojima S et al. A new method for measuring tears. CLAO J. 1983;9(3):281-289.
  27. Mengher LS, Bron AJ, Tonge SR, Gilbert DJ. Effect of fluorescein instillation on the pre-corneal tear film stability. Curr Eye Res. 1985;4(1):9-12. https://doi.org/10.3109/02713688508999961
  28. Lee JH, Hyun PM. The reproducibility of the Schirmer test. Korean J Ophthalmol. 1988;2(1):5-8. https://doi.org/10.3341/kjo.1988.2.1.5
  29. Monts-MicR, AliJL, Muoz G, Prez-Santonja JJ, Charman WN. Postblink changes in total and corneal ocular aberrations. Ophthalmology. 2004;111(4):758-767. https://doi.org/10.1016/j.ophtha.2003.06.027
  30. Jeon HM, Lee DJ. Objective optical quality analysis in dry eye syndrome. J Korean Ophthalmol Soc. 2014;55(11): 1600-1605. https://doi.org/10.3341/jkos.2014.55.11.1600
  31. Lee BJ, Hong JH, Jung DI, Park M. A study on the confidence of dry eye diagnosis methods. J Korean Ophthalmic Opt Soc. 2008;13(1):15-20.

Cited by

  1. Evaluation of the dermatologic life quality among cleanroom workers in a secondary battery factory vol.28, pp.1, 2016, https://doi.org/10.1186/s40557-016-0125-0
  2. Analysis of Tear Meniscus using Optical Coherence Tomography after Cataract Surgery vol.23, pp.4, 2018, https://doi.org/10.14479/jkoos.2018.23.4.503