• Title, Summary, Keyword: 연계된 제어력

Search Result 39, Processing Time 0.074 seconds

Dynamic Characteristic of A Bi-dirctional Damper Using A Tuned Mass Damper and A Tuned Liquid Column Damper (TMD와 TLCD를 이용한 2방향 감쇠기의 동적특성)

  • Lee, Sung-Kyung;Min, Kyung-Won;Park, Eun-Churn
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.6
    • /
    • pp.589-596
    • /
    • 2008
  • This study introduces the design of a bi-directional damper using a tuned mass damper(TMD) and a tuned liquid column damper(TLCD) and presents experimental verifications to confirm its control performance. The damper used in this study behaves as a TMD in a specific translational direction and acts as a TLCD in the other orthogonal direction. First, shaking table test is performed to investigate the coupled effect of control forces produced by TMD and TLCD. Then, the parameters that affect to dynamic characteristics of the proposed damper are quantitatively evaluated based on the experimental results. Testing results shows that the damper used in this study produces control forces coupled by TLCD and TMD, as it is excited by waves with an incident angle. Also, it is observed that the damper can be used to reduce bi-directional responses of building structures.

A Control Method and Test Results of Utility-Interactive Photovoltaic Power Generation Systems (계통연계 태양광발전시스템의 제어기법 및 연계운전특성)

  • 황인호;안교상;임희천;김신섭
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.123-129
    • /
    • 2000
  • This paper desclibes a design method and test results of grid-connected photovoltaic power 당eneration s systems, which consists of solar cells, DCI AC inverter, utility grid. A 50 kW photovoltaic power generation s system including a 3-phase DCI AC inverter is designed and made in order to investigate the system l pelionnance for glid connection. Also the control scheme of a three phase cmrent-controlled PWM inverter W with PI controller is presented by using d-q transformation. The experimental waveforms show that the p proposed system has stable behavior with em unit power factor in utility-interactive operation.

  • PDF

Theory and Application of SVC (Thyristor제어 정지형 무효전력 보상기(SVC)의 원리 및 응용)

  • 윤성병
    • Journal of the Korean Professional Engineers Association
    • /
    • v.22 no.3
    • /
    • pp.14-20
    • /
    • 1989
  • 전력수요의 급증에 따라 단위기의 용량 및 전력계통의 규모가 대형화되어 지속적인 안전운전이 계통운용의 최우선 과제가 되였으며, 신뢰도향상 및 계통간전력수급의 원활한 융통을 위하석 계통간의 연계는 물론 다계통간의 다중연계에 이어 국가간의 연계도 이루어지고 있다. 본고에서는 전력계통의 대형화 및 연계화 추세에 따라 계통 무효전력 조류의 신속한 조절과 속응전압조정의 필요성이 증대되어 그 응용이 확산되고 있는 Thyristor제어 정지형 무효전력 보상기(이하 SVC라 칭함)의 원리, 특성, 응용 및 계통에 미치는 효과에 대하여 고찰하였다.

  • PDF

A Study of linking methodology of Direct Load Control and Unit Commitment Considering System Spinning Reserve Characteristics (계통운전예비력특성을 감안한 직접부하제어와 기동정지계획의 연계방법에 관한 연구)

  • Lee, Buhm
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.4
    • /
    • pp.826-832
    • /
    • 2003
  • This paper presents a new linking methodology of direct load control(DLC) and unit commitment(UC) considering system spinning reserve characteristics. To consider system spinning reserve characteristics, we formulate new constraints. And to link DLC and UC, we employed 3-Dimensional dynamic programming which has DLC state, UC state, and stage. As a result, economical DLC and UC schedule of the power system is possible. This method is applied to the test system, and the usefulness of the method is verified.

Study of Required Frequency Ancillary Service Reserve for DC Distribution Connected Power System (직류 배전 투입 증가에 따른 필요 계통 주파수 조정 예비력 변동성 연구)

  • Suh, Jaewan;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • /
    • pp.274-275
    • /
    • 2015
  • 에너지저장장치, 태양광 발전기, 전기자동차 등 직류 사용설비의 급증으로 인해 직류 배전 혹은 직류 마이크로그리드에 대한 관심이 증가하고 있다. 직류 배전은 전력변환을 최소화하여 효율이 높고 수변전 설비 공간이 절약되는 장점이 있다. 하지만 직류를 통해 계통에 연계된 부하와 설비들은 별도의 제어가 없으면 관성과 주파수-부하 반응을 제공할 수 없다. 따라서 직류 배전 투입이 늘어날수록 전력계통의 관성과 주파수-부하 반응이 감소하게 되어 계통 주파수 변동 발생 시 변동 속도와 크기가 증가하게 된다. 때문에 계통 운영자는 더 많은 주파수 조정 예비력을 확보하여야 한다. 본 논문에서는 동요방정식을 이용하여 직류 배전 투입에 따라 계통 관성과 주파수-부하반응이 줄어듦에 따라 변하는 필요 주파수 조정 예비력 량을 계산하는 방법을 제시하고 있으며 MATLAB을 이용하여 직류배전 투입 비율에 따른 필요 주파수 조정 예비력 량 변화를 모의하였다.

  • PDF

Development of Linking Methodology of Direct Load Control and System Economic Operation (직접부하제어와 계통경제운용의 연계기법 개발)

  • Lee, Buhm
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • /
    • pp.594-597
    • /
    • 2003
  • To link direct load control and economic operation considering system spinning reserve characteristics, this paper presents a new metholodogy. By formulating new constraints, considering system spinning reserve characteristics is possible. And by employing 3-D dynamic programming, linking direct load control and economic operation is possible. As a result, economical DLC and operation schedule of the power system is possible. The usefulness of the method is verified by applying to the test system.

  • PDF

A Development on Reserve Monitoring Algorithm for K-EMS (K-EMS 예비력감시 알고리즘 개발)

  • Lee, Jeong-Ho;Oh, Tae-Kyoo;Lee, Jin-Su;Seo, Eun-Sung;Kim, Ki-Woon
    • Proceedings of the KIEE Conference
    • /
    • /
    • pp.42-43
    • /
    • 2008
  • 본 논문은 한국형 에너지관리시스템 (K-EMS)의 발전계획 응용프로그램 기능중 하나인 예비력감시 응용프로그램 개발을 위한 예비력감시 알고리즘 개발에 관한 것이다. 예비력감시 응용프로그램은 EMS에서 실시간으로 수행되어 급전원에게 제어지역별, 발전소별, 발전기별로 현재 전력계통의 유효전력 예비력을 제시한다. 본 예비력감시 알고리즘은 국내 전력시장운영규칙의 예비력 항목으로 정의된 주파수조정 예비력, 운전상태 대기예비력, 정지상태 대기예비력, 대체예비력, 운영예비력을 계산한다. K-EMS에서는 경제급전 응용프로그램과 예비력감시 응용프로그램을 연계하여, 요구된 주파수 조정예비력 확보량을 만족하도록 경제급전에서 발전력을 조정한다. 국내 전국계통 실시간 데이터를 이용하여 K-EMS 실시간 예비력감시 알고리즘을 시험하였다.

  • PDF

직류송전의 현황과 전망

  • 유인근;이형권
    • 전기의세계
    • /
    • v.35 no.11
    • /
    • pp.710-715
    • /
    • 1986
  • 직류송전은 선로의 건설비가 저렴하고 안정도의 문제가 없어 대전력 장거리송전이 가능하며, 비동기 연계를 할 수 있고, 조류제어가 신속.용이할 뿐만 아니라 단락용량을 증가시키지 않고도 계통의 연계강화가 가능한 점등의 잇점이 있으며, 특히 케이블 송전에 매우 유리한 송전방식이다. 그러나 선로의 건설비는 교류송전방식에 비해 저렴한 반면, 교직변환소의 건설비가 고가이므로 소용량 근거리 송전에는 경제성이 없으며, 고조파 및 고주파 장해대책이 필요하고, 전력계통 구성의 자유도가 떨어지는 점등의 문제가 있다. 본고에서는 직류송전의 역사적 배경과 설비의 현황, 운전실적 및 연구추진현황, 금후의 전망등에 관해서 기술하였다.

  • PDF

The System Frequency Impact of an Increasing Amount of Wind Power in Weak Grids (소규모 전력계통에서 풍력발전 증대에 따른 계통주파수 영향)

  • Lee, Seung-Keu;Lee, Jong-Soon;Park, Jin-Woo;Lee, Kang-Wan
    • Proceedings of the KIEE Conference
    • /
    • /
    • pp.210-213
    • /
    • 2007
  • 오늘날 풍력발전은 신재생에너지 중에서 실효성 및 경제성이 우수한 에너지원으로 지속적인 기술개발에 따라 규모의 대형화와 더불어 이의 확산이 빠르게 진행되고 있어 전력계통에서 차지하는 비중이 점점 증대되고 있다. 바람이 많은 제주도는 풍력발전에서 비교적 유리한 지역으로 평가되고 있어 앞으로 많은 풍력발전설비가 설치될 전망이다. 그러나 풍력발전은 특성상 전력품질 적정 유지 및 전력공급 신뢰도 측면에서 취약한 형태이며 특히 HVDC로 내륙 전력계통과 연계된 제주 전력계통은 HVDC 운전 형태에 따라 순동예비력 확보가 다르게 되어 계통주파수 제어에 어려움이 있게 된다. 본 논문은 HVDC로 연계된 소규모 전력계통인 제주 전력계통의 풍력발전 중대에 따른 계통주파수 변화 특성을 과도안정도 해석프로그램으로 분석하여 풍력발전시스템 계통 연계관련 안전성 등을 조사한 것이다.

  • PDF

Digital Control System Validation using the Simulator Models for 500MW Standard Type Fossil Power Plant (500MW급 표준화력발전소 시뮬레이터 모델을 이용한 디지털 제어시스템 검증)

  • Suh, Jeong-Kwan;Lee, Myeong-Soo;Hong, Jin-Hyuk
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.3
    • /
    • pp.71-79
    • /
    • 2010
  • The simulator models for 500MW fossil power plant have been developed, and interconnected with the turbine control system to test and validate the digital instrumentation & control (I&C) systems before they are implemented in operating power plants. When the performance of a selected digital I&C system is tested, the corresponding simulator model is replaced by the plant digital I&C systems which is considered as a non-tunable system. The input/out variables of simulator models and control systems were mapped using the LabView in interface systems. This paper describes the interconnection method between the simulator model and the digital I&C system, and summarizes the validation test results performed at the condition of steady-state operation, normal evolution, and malfunction. The integrated validation method of digital I&C systems using the simulator models showed that the simulator can be used as a test bed for the implementation of digital I&C systems in power plants.