• Title, Summary, Keyword: 펄스레이저

Search Result 827, Processing Time 0.047 seconds

Theoretical analysis improved cavitity design of a 10 GHz harmonically mode-locked Er-doped fiber laser (10GHz로 고조모드록킹된 고리형 어븀첨가 광섬유 레이저의 이론적 해석 및 향상된 공진기 설계)

  • 이유승
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.5
    • /
    • pp.353-359
    • /
    • 2000
  • A harmonically mode-locked fiber ring laser cavlty was theoretically analyzed. The measured charactenstlcs of a 10 GHz erbium-doped fiber ring laser were used as a basis of the theoretical analysis. From the nonlinear Schroedinger equation of an actively mode-locked erblUm-doped fiber laser. the effects of the components inside the laser cavity have been analyzed includmg nonlinear effects from group-velocity dispersion (GVD) and self-phase modulation (SPM). Usmg the analysls. we have designed a laser cavity with minimum pulsewidth and chirp by changing the intracavity optical intensity and the bandwidth of the filter. In the new design, the chirp i, reduced by 2 times and the pulsewidth by 2A times. compared to the laser used in the experiment. iment.

  • PDF

Single Longitudinal Mode Operation of a Pulsed Dye Laser Injection-seeded with a CW Ring Dye Laser (인젝션 록킹 방법에 의한 펄스 색소레이저의 단일 종모우드 발진)

  • 김재완;공홍진;한재원;박승남
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.84-89
    • /
    • 1994
  • A tunable pulsed dye laser was operated in a single longitudinal mode by injection locking with a cw ring dye laser. A doubled Nd:YAG laser was used as the pumping source. Phase sensitive detection technique was applied to maintain the required match between the master laser frequency and the slave resonator cavity length. The fluctuation of the center frequency of the pulsed laser was < 10 MHz, and the pulse duration (FWHM) was 6 ns. The linewidth measured by scanning confocal interferometer was 130 MHz. When pumped by 50 mJ of the doubled Nd:YAG laser, the output energy of the pulsed dye laser was 2 mJ and the peak power was 330 kW. 30 kW.

  • PDF

Pulse Shortening by a Kerr Cell in an Iodine Laser and the Amplification of a Shortened Pulse (Kerr cell을 이용한 옥소 레이저의 펄스폭 단축과 압축된 펄스의 증폭)

  • ;;;;M.R.Motchalov
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.26-32
    • /
    • 1995
  • A Kerr cell was utilized as an optical shutter to generate a shortened pulse and as an isolator between amplifiers in an iodine laser system. By rotating the polarization of incident laser pulse only during the timing window of high voltage applied to the Kerr cell, shortened pulses of 5 ns and 1 ns, corresponding to the difference in propagation time of two coaxial cables, were obtained. It was also noticed that more than one timing window of Kerr cell was produced with a long incident laser pulse from the oscillator. The measured transmittance of Kerr cell with respect to applied voltage was compared with the theoretical estimation using the electro-optic Kerr effect theory. Through the amplification of the shortened pulse in iodine amplifiers. a pulse of 0.5 GW(2 J in 4 ns) was obtained. ained.

  • PDF

Design and evalution of pulsed $CO_2$ laser system using high repetition ratio and high precision (고반복율 및 고정밀방식을 이용한 펄스형 $CO_2$ Laser 시스템 설계 및 평가)

  • 김흥수;김휘영
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.8
    • /
    • pp.1055-1062
    • /
    • 2001
  • Study, it is the purpose to develope a cheap and compact pulsed $CO_2$ laser with pulse repetition rate range of 1 KHz. We used a IGBT switched power supply as a power supply, which is cheap and simple comparing to others. PIC one-chip microprocessor was used for precise control of a laser power supply on the control part. And the laser cavity was fabricated as an axial and water cooled type. The laser performance characteristics as various parameters, such as pulse repetition rate, gas pressure, and gas mixture rate have been investigated. The experiment was done under the condition of total pressure of $CO_2$$N_2$:He = 1:3:10, 1:1.5:5, 1:9:15 from 6 Torr to 15 Torr and pulse repetition rate from 100 Hz to 900 Hz. As a result, the maximum average outpu was about 20.5 W at the total pressure of 15 Torr, the gas mixture $CO_2$$N_2$:He = 1:9:15 and the pulse repetition rate of 700 Hz.

  • PDF

Cr:YAG 포화 흡수체를 이용한 Nd:YVO$_4$ 레이저의 수동형 Q-switching 특성

  • 이희철;김규욱;김칠민
    • Proceedings of the Optical Society of Korea Conference
    • /
    • /
    • pp.42-43
    • /
    • 2001
  • Nd:YVO$_4$ 결정은 들뜬 상태의 발광 평균 수명이 90-100 $\mu\textrm{s}$로 아주 짧아서 Nd:YAG나 Nd:YLF 레이저 매질에 비해 짧은 펄스폭과 빠른 반복율을 가진 펄스들을 만들어 내는 Q-switching에 적합한 레이저 매질이다. 또한 Nd:YAG 결정에 비해 아주 큰 흡수 계수 및 이득 단면적을 지니고 있어 반도체 레이저로 펌핑하는 고체 레이저에 아주 적합한 레이저 이득 매질이다. (중략)

  • PDF

Study on the Core Loss Improvement of SiFe Plate in Relation with Laser Pulse Width in the Laser Scribing (레이저 스크라이빙에 있어서 레이저의 펄스폭에 따른 규소강판의 코어손실 개선 연구)

  • Ahn, Seung-Joon;Park, Chul-Geun;Ahn, Seong-Joon
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.6
    • /
    • pp.320-324
    • /
    • 2005
  • The core loss of $3\%$ SiFe is strongly dependent on silicon content, impurities, permeability, and domain structure of the SiFe. Domain refining has been proved to be very good method for reduction of core loss in high permeability grain oriented SiFe, and laser scribing is well-blown as an effective and industrially important method of domain refinement. In this work, magnetic domain refinement has been carried out by using a pulsed Nd : YAG laser, and the core losses have been measured and analyzed to and optimal parameters of the laser treatment. The laser hem was focused with a spot size of $100{\mu}m$ and pulse energy of 10${\~}$35mJ and the lines were scribed with a period of ${\~}$5mm. The core loss was improved up to $17\%$ with 30 ns-Nd : YAG laser beam in $3\%$ SiFe.

Ablation Effects of Er:YAG Laser at Various Energy Levels, Different Repetition Rates and Irradiation Time on Enamel (Er:YAG 레이저를 법랑질에 조사 시 에너지수준, 조사반복율 및 조사시간에 따른 삭제효과)

  • Lee, Sae-Yong;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.4
    • /
    • pp.395-406
    • /
    • 2001
  • 지난 수십년동안, 다양한 레이저기기를 이용하여 치아 경조직에 대한 응용 실험을 수행되었다. 그러나, 발생한 주요한 문제는 열발생과 플라즈마 형성과 같은 부작용이 지속된다는 점이었다. 실망스러운 실험결과에 따라 치아 삭제에 대한 레이저의 응용에 대한 연구가 거의 진행되지 못하였다. 본 연구의 목적은 국내에서 처음으로 개발된 얼비움레이저기기를 사용하여 다양한 에너지 수준과 다양한 펄스빈도에서 법랑질의 삭제율을 비교하고자 하였다. 본 연구에 사용된 레이저기기는 국내에서 최초로 개발된 $2.94{\mu}m$ 펄스를 $250{\mu}s$ 방출하는 얼비움야그레이저 기기이다. 기기의 에너지는 20 mJ에서 350 mJ까지 다양하게 방출하며, 최대 출력은 3.5 W이다. 22개의 치아를 에폭시 레진에 포매하고 경화하였다. 치아의 법랑질을 회전 다이아몬드 칼을 흐르는 물과 함께 사용하여 협측 또는 설측으로 평탄하게 삭제하였다. 제작된 법랑질표면은 6개의 구획으로 구분하여 에너지 수준과 펄스빈도에 따라 조사하였다. 본 연구에서 사용된 표본 수는 132개이며, 삭제율을 조사하기 위한 모든 표본은 22개의 실험 군으로 분류하였다. 실험결과는 다음과 같다. 1. 에너지 수준간에는 유의한 삭제율의 차이가 있었다. 2. 40 및 80 mJ로 조사한 경우에는 펄스빈도 간에 차이가 없었지만, 120 mJ의 출력으로 동일한 에너지를 조사한 경우에는 20 Hz가 40 또는 80 mJ로 조사한 경우 보다 가장 삭제효과가 높았다. 3. 연속조사 한 경우 조사시간 경과에 따라 법랑질의 삭제율은 증가되지 않았다. 결론적으로 효과적으로 법랑질을 삭제하기 위해서는 적절한 에너지와 펄스의 레이저를 사용해야 하며, 또한 항상 정확한 초점거리를 유지해야 할 것으로 사료된다.

  • PDF

Characteeristics of a Ultrashort Pulse Dye Laser and its Application (극초단 펄스 색소레이저의 특성과 응용)

  • 임용식;김광훈;문희종;고춘수;이재형;장준성
    • Proceedings of the Optical Society of Korea Conference
    • /
    • /
    • pp.177-184
    • /
    • 1995
  • 피고초 및 펨퍼초 펄스를 얻기 위한 동기형(Synchrous mode-locking) 및 혼합형 모드결합(Hybrid mode-locking) 방식이 색소레이저에서의 출력특성에 대하여 연구하였다. 피고초 및 펨퍼스 펄스의 발생원리에 대하여 논하고, 군속도 분산과 자기위상변조와 같은 펨퍼토 펄스의 형성원리 사이의 연관성에 대하여 논한다. 또한 펨도초 펄스의 시분해 응용으로 축퇴 4광파 혼합법으로 미소반도체 CdSSe(Re645)에서 위상이완시간(Dephasing time)의 측정에 관하여 논한다.

  • PDF

간단한 양자계와 빛의 상호작용

  • Kim, Jun-Hyeong;Jang, Bo-Yeong;Sin, Seok-Min
    • Proceeding of EDISON Challenge
    • /
    • /
    • pp.132-144
    • /
    • 2017
  • 현재, 빛을 이용한 화학 연구가 활발히 진행되고 있고 이러한 연구는 양자역학을 기반으로 화학에서 상당히 중요한 부분을 차지하고 있다. 또한 컴퓨터의 발전에 따라 여러 계산 모델들이 개발되고 있다. 본 논문에서는 회전파 근사(Rotating Wave Approximation, RWA)를 통해 라비 진동을 이론적으로 확인하고, 가장 간단한 연속파 레이저와 두 에너지 준위에서 시작하여 레이저 펄스와 두 에너지 준위, 레이저 펄스와 이원자분자인 $Na_2$ 분자의 두 전자에너지 퍼텐셜 준위, 그리고 실제 시간 밀도 범함수 이론(Real-Time Time Dependent Density Functional Theory, RT-TDDFT)이란 제일원리계산을 통해 연속파 레이저와 $H_2$ 분자와 $C_2H_4$ 분자에서까지 관찰하였다. 이 연구를 통해 공명 전이의 경우 펄스의 면적이 ${\pi}$의 홀수 배일 때 완전한 입자수 전이가 일어나는 펄스 면적 정리를 확인할 수 있었고, 이원자분자인 $Na_2$의 경우엔 펄스의 지속시간도 입자수 전이에 영향을 미친다는 것을 확인하였다. 더 나아가 $H_2$ 분자와 $C_2H_4$ 분자에서는 RT-TDDFT 계산을 통해 라비 진동을 확인할 수 있었고, 두 종류의 기저함수간의 대조를 통해 기저함수 선택의 중요성을 알아보았고, 가장 중요하게는 레이저를 잘 조작하면 입자를 원하는 상태로 들뜨게 할 수 있다는 것이란 결론을 얻게 되었다.

  • PDF

Effects of Low-Level Laser Irradiation on the ALP Activity and Calcified Module Formation of Rat Osteoblastic Cell (저수준레이저(GaAs 반도체)조사가 골모세포의 알칼리성 인산분해효소의 활성과 석회화결절의 형성에 미치는 영향)

  • Kyung-Hun Lee;Ki-Suk Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.2
    • /
    • pp.279-291
    • /
    • 1996
  • 저수준레에저요법에 대해서는 지난 10여년간 의학계 및 치과계에서 임상적으로 사용하여 좋은 결과가 있다고 많은 보고가 발표되고 있다. 특히 치근의 골결손에 관한 연구에서는 전기요법, 초음파요법, 전자장요법 등 뿐만아니라 저수준레이저를 사용하여 골절부내 Callus형성이 촉진되었음을 보고하고 새로운 치료법의 하나가 될 수 있음을 제안한 바도 있다. 본 연구에서는 칼륨비소를 다이오드로 사용한 저수준레이저조사가 골결손의 치유에 어떠한 영향을 미치는지 확인하고자 골모세포의 알칼리성 인산분해효소의 활성화와 석회화결절의 형성을 평가함으로 골모세포의 기능을 조사코저하였다. 실험은 첫째, 9개군으로 나누어 레이저 조사기간에 따른 알칼리성 인산분해효소의 활성화를 조사하였고, 둘째, 이를 근거로 9일간 계속 매일 1회 1.3 J/cm2의 레이저를 조사한 후 펄스의 종류별 차이를 비교하였으며, 세째,레이저펄스별 석회차 결절의 형성 정도를 광학현미경으로 관찰하여 비교분석하였다. 결과, 7일 계속 레이저를 조사한 경우 다른 군에 비해 서서히 ALP의 활성이 증가하였으나 유의한 차이는 없었으며. 따라서 9일동안 레이저를 계속 조사한 경우에는 전체 에너지량이 5.895 J/cm2 인 펄스13과 15가 뚜렷하게 유의한 증가를 보여주었다. 그러나 석회화결절의 형성은 전체 에너지량이 2.546 J/cm2 인 펄스11에서 가장 많았다. 결론적으로 골형성이나 알칼리성 인산분해효소의 활성을 촉진하는 데에는 적절한 레이저 조사조건이 필요하나, 알칼리성 인산분해효소의 활성을 촉진한 펄스와 석회화결절의 형성을 촉진하는 펄스가 서로 다르게 나타난 것은 골형성을 촉진하는 여러요인 들이 저수준레이저에 자극받았을 가능성이 높음을 보여준다 이러한 결과들로 보아 저수준레이저는 골모세포의 기능을 자극하여 골결손의 치유를 개선하는 데 도움될 것이라 사료된다.다. 각 백서의 양측 창상중 하나는 1,3,5,7일 마다 각 실험의 방법에 따라 레이저를 조사하고 실험동물의 다른 창상은 대조군으로서 사용하였다. 모든 창상의 면적은 실험 1,3,5,7 일째에 일정한 거리에서 사진촬영하여 면적계를 이용, 측정한 후 통계적인 의의를 조사하였다. 본 연구의 결과는 저수준레이저는 특정 조건하에서 S. aureus의 증식을 촉진하였다. 그러나 S. aureus에 감염된 창상을 저수준레이저로 조사시 치유가 촉진되었다. 중앙 조사법고 주변조사법에 의한 창상치유효과는 통계적인 의의가 보이지 않았다. 따라서 결론적으로 S. aureus 에 감염된 창상에 직접 또는 간접적이든 pulse의 종류에 관계없이 조사하는 경우 치유효과가 나타나는 것은 정사주위 조직의 LLLI 자극효과가 염증의 확산을 억제한다고 말할수 있다.4/1$0^{\circ}C$에서는 Shoa-Nan-Tsan과 Lenkwang이 가장 높았으며 백앙벼는 3 온도 조건 모두에서 활성이 낮았다. 발아소요일수와 amylase 활성과는 유의적인 정의 상관관계를 보였다., 다다조, 미국의 건답직파재배 품종 등이었으며 우리 나라 육성종들은 모두 지중에서 신장이 멈추어 제1본엽이 지중에서 추출하였으며, Scm파종심에서 불완전엽이 지면을 뚫고 나오는 품종은 Chinsura Boro뿐이었고 Nato, Labelle, Weld Pally, Italliconaverneco 등도 지면 가까이 까지 신장하였다. 6. 50% 출아일수는 제2절간장을 제외 한 모든 유아 형질의 신장도와 유의한 부의 상관을 보였는데 가장 높은 상관을 보인 것은 중배축장+제1절간장+불완전옆장이었으며, 다음이 불완전엽장이 었다. 7. 출아율은 중배축장+제1절간장+불완전엽장, 중배축장+초엽 장과 모든 파종심에서 높은 정의 상관을 보여 제1본엽의 추출 위치가 높을수록

  • PDF