• Title, Summary, Keyword: 펄스레이저

Search Result 827, Processing Time 0.044 seconds

Ablation characteristics of femtosecond laser pulse-induced pressure waves in biological tissue (펨토초 펄스로 인한 조직 제거시 생성된 압력파의 특성 연구)

  • ;A. Komashko;M. Feit;A. Rubenchik
    • Proceedings of the Optical Society of Korea Conference
    • /
    • /
    • pp.244-245
    • /
    • 2002
  • 1 picosecond 보다 짧은 펄스길이를 갖는 초단파길이 레이저 펄스 (Ultrashort laser pulse, USLP)를 이용한 물질의 절제 (ablation)는 여타 nanosecond 영역의 레이저 절제와 많은 차이를 보인다(1). USLP는 순간 파워가 매우 높기 때문에 직접적으로 물질의 원자를 분리시켜 자유전자를 형성한다 이들 자유전자는 일반 선형흡수체 (linear absorbing chromophore)보다 흡수계수가 몇 십 배로 높아 대부분의 펄스 에너지가 표면 100-200 m 이내의 극히 작은 지역에 밀집되게 된다. (중략)

  • PDF

Laser Diode Pumped Mode-Locked $1.3{\mu}m$ Nd-YAG Laser (모드록킹된 다이오드 여기 $1.3{\mu}m$ Nd:YAG 레이저)

  • Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • /
    • pp.271-274
    • /
    • 2007
  • 본 연구는 $1.3{\mu}m$ 파장의 초고속 Nd:YAG레이저 펄스를 얻기 위해 AOM을 이용하여 모드록킹 Nd:YAG레이저 공진기를 구성하였다. 여기용 반도체 레이저는 중심파장 810nm, 출력 1.2W이며, 레이저 매질은 직경 3mm, 길이 10mm로 $Nd^{3+}$가 1.0at%로 도핑된 Nd:YAG Rod를 사용하였다. 모드록킹에는 음향광학 변조기(변조 주파수 40MHz)를 사용하여 펄스폭 ${\tau}p=80ps$의 극초단 펄스를 얻었다.

  • PDF

Laser Induced Microjet Drug Delivery System: Drug Permeation Depending on Laser Wavelength and Pulse Duration (레이저 유도 마이크로젯을 활용한 약물 전달 방식: 레이저 파장 및 펄스길이에 따른 약물 침투 분석)

  • Jang, Hun jae;Ham, Hwi chan;Yoh, Jai ick
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.7
    • /
    • pp.463-468
    • /
    • 2017
  • For transdermal drug delivery, needless injection system is composed of laser and microjet injector. Main mechanism of microjet injector is the laser-induced bubble. Nd:YAG and Er:YAG laser are used as a power source. Laser parameters such as pulse duration and wavelength are considered, which are core parameters to control the bubble motion. The Nd:YAG laser, pulse duration is short than bubble life time making cavitation like bubble while in Er:YAG laser, long pulse duration and high absorption in water drive bubble as a boiling bubble. Detailed motion of bubble and microjet is captured by the high speed camera. So it is observed that microjet characteristics are determined by the bubble behavior. The performance of drug delivery system is evaluated by fluorescent staining of guinea pig skin.

Theoretical Analysis of Impact of Q-switch Rise Time on Output Pulse Performance in an Ytterbium-doped Actively Q-switched Fiber Laser (이터븀 첨가 능동형 Q-스위칭 광섬유 레이저에서 Q-스위치 상승 시간이 출력 펄스에 미치는 영향에 대한 이론적 분석)

  • Jeon, Jinwoo;Lee, Junsu;Lee, Ju Han
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.2
    • /
    • pp.58-63
    • /
    • 2013
  • A theoretical analysis of the impact of rise time of a Q-switch on the output pulse performance is carried out in an Ytterbium-doped actively Q-switched fiber laser. The finite difference time domain (FDTD) method is used to numerically simulate the Q-switched fiber laser. It is shown that stable Gaussian-like pulse shape can be generated when the Q-switch rise time is increased and pulse repetition rate is enlarged.

Comparison of Wound Healing in Porcine Skin with Continuous-Wave and Pulsed Mode $CO_2$ Laser Incisions (돼지에서 연속형 $CO_2$ 레이저와 펄스형 $CO_2$ 레이저를 이용한 피부절개시 창상치유 평가)

  • Lee, Jae-Yeon;Cho, Sung-Whan;Park, Chang-Sik;Kim, Myung-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.27 no.6
    • /
    • pp.647-651
    • /
    • 2010
  • The advantages of the $CO_2$ laser are offset by the delay in laser wound healing secondary to thermal damage. To minimize the undesirable thermal damage of the $CO_2$ laser, investigators have developed technical advances in the delivery system of the laser energy. This study compared tissue healing of the continuous and the pulsed modes $CO_2$ laser wounds in an animal surgery model. Five healthy Landrace and Yorkshire mixed breeds of both genders were used (45-51 kg, 4-6 months old, three males and two females). A full thickness wound of skin ($2{\times}2{\times}2cm^2$) was made over on the each pig's both sides of dorsal midline at 0, 7, 14, and 18 days. The wounds created at 18, 14, 7 and 0 days were named post-wounding day (PWD) 3, 7, 14 and 21, respectively. In each pig, one wound (left side) was treated pulsed $CO_2$ laser and the other wound (right side) was treated continuous wave $CO_2$ laser. Each wound was closed with two interrupted suture of 3-0 sutures. At 21 days after initial wounding, each wound was taken for histological evaluations. The degrees of reepithelialization were performed more prominently in the pulsed mode group than in the continuous mode group. The degrees of granulation were greater significantly in pulsed mode group than those in the continuous mode on PWD 3 (p < 0.05). The degrees of fibroblasts in the pulsed mode group were greater significantly in comparison to those in the continuous mode group on PWD 7, (p < 0.05). In conclusion, reepithelialization, granulation and fibroblasts in the pulsed mode group were greater markedly in comparison to those in the continuous mode group. It was considered that pulsed mode $CO_2$ laser was more suitable for the skin incision than the continuous mode $CO_2$ laser.

Characteristics of Nd:YAG Laser Pumped by cw Ti:sapphire Laser and Its Passive Q-switching with Cr4+:YAG as Saturable Absorber (Cr4+:YAG 포화 흡수체를 이용한 Ti:sapphire 레이저 여기 Nd:YAG 레이저의 수동형 Q-switching 특성)

  • 안범수;추한태;김규욱
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.263-267
    • /
    • 2004
  • We have investigated the characteristics of a Nd:YAG laser pumped by a cw Ti:sapphire laser. When the pumping power of the Ti:sapphire laser was 850 ㎽, the maximum output power of the Nd:YAG laser was 450 ㎽. As a result, the slope efficiency for the output power of the Nd:YAG laser was measured to be 56%. We have also investigated the characteristics of a passively Q-switched Nd:YAG laser by using a Cr$^{4+}$:YAG as saturable absorber with initial transmission of 90%. The maximum average output power of 200 ㎽ was obtained with repetition rate of 23.8 KHz and pulse width of 17.0 ns.

펄스레이저 증착법의 원리와 응용

  • 이상렬
    • 전기의세계
    • /
    • v.45 no.5
    • /
    • pp.17-22
    • /
    • 1996
  • PLD 장치는 진공 또는 반응가스가 채워진 챔버안에 다층 박막을 증착시킬 수 있는 여러개의 타겟홀더와 기판홀더가 존재하고 물질을 기화시켜 박막을 증착시키기 위해 외부 에너지원으로 고출력 레이저가 사용되며, 일련의 광학장치들은 타겟표면에 레이저 빔을 접속시키고 주사하기 위해 사용된다. 타겟표면에 접속된 레이저 빔은 타겟표면 물질을 플라즈마 (또는 플룸) 상태로 만들고 이 플룸이 결정화에 알맞는 온도로 가열된 기판위에서 결정구조를 가진 박막을 형성한다. 진공장치와 기화에너지원의 분리는 PLD 시스템을 유연하게 해서 내부적으로 기화에너지원의 사용에 의한 제한없이 다른 동작 모드에 쉽게 적용할 수 있다.

  • PDF

펄스 레이저를 이용한 고온 초전도박막 증착의 레이저-타깃 반응 기구

  • Seo, Jeong-Dae;Gang, Gwang-Yong;Seong, Geon-Yong
    • Electronics and Telecommunications Trends
    • /
    • v.7 no.3
    • /
    • pp.84-95
    • /
    • 1992
  • 본 고에서는 $YBa_2Cu_3O_7_x$ 고온초전도 물질의 박막제조에 있어서 현재 가장 각광을 받고 있는 펄스 레이저 증착공정의 원리, 특징등을 살펴보았다. 특히, 이 공정에서 입사 레이저와 고체 타깃간의 상호작용으로 인한 플룸의 발생, 물질의 방출, 기판상의 증착 등과 관련된 반응기구를 중점적으로 기술하였다.

Ultrafast Laser Micro-machining Technology (극초단 펄스 레이저 응용 미세가공기술)

  • Lee, Jae-Hoon;Sohn, Hyon-Kee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.2
    • /
    • pp.7-12
    • /
    • 2010
  • Due to the extremely short interaction time (< $10\times10^{-12}$sec) between laser pulse and material, which enables the minimization of heat affection, ultrafast laser micro-machining has rapidly widened its applications. In this paper, the characteristics of ultrafast laser micro-machining have been reviewed and experimentally demonstrated in laser drilling of silicon wafer and in laser cutting of rigid PCB.

펨토초 레이저를 이용한 극미세 가공에의 응용

  • 조성학
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • /
    • pp.8-8
    • /
    • 2004
  • 펨토기술은 펨토초영역에서 일어나는 물리화학적 현상을 이용하여 공학적으로 이용하는 학문이다. 펨토초(femtosecond)는 시간의 단위로서 1펨토초는 1000조분의 1초($10^{-15}$)에 해당된다. 일반적으로 사람의 머리카락 두께는 약 100fm 인데 100 펨토초라고 하더라도 빛이 머리카락 두께의 1/2도 진행하지 못하는 극도의 짧은 시간에 불과하다. 이러한 펨토기술은 극초단 레이저의 발달로 가능해졌다. 1960년대 초 레이저 펄스폭을 줄일 수 있는 기술이 개발돼 나노초 시대가 열린 이후 60년대 중반에 펄스폭을 더욱 줄일 수 있는 모든 잠금기술이 개발돼 피코초 시대가 도래했다.(중략)

  • PDF