표면 거침도에 따른 종이절연지의 전계분포 (Electric field distribution according to surface roughness of insulating paper)

  • 박형준;김원종;신종열;이수원;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • /
    • pp.323-326
    • /
    • 2004
  • The this paper is describing about the electric field distribution due to the roughness in Aramid insulating paper for electric machine. The insulting and pressboard paper have been used at electric insulating of traction motor and generators. There was a change investigation of the electric field distribution according to the roughness of specimen by simulation program of Electro. We studied the electric field distribution using boundary element method for Aramid insulator. We find out an optimal condition in insulating paper of electric machine.

  • PDF

부분방전 전자파 측정용 광대역 주파수 분석 시스템 개발 (The Development of wide frequency analyzing system by partial electric discharge electromagnetic-wave Receiver)

  • 박두용;신영진
    • 대한전기학회:학술대회논문집
    • /
    • /
    • pp.547-549
    • /
    • 2004
  • This system is monitors the degree of aging happened at the electric machine. It detects electromagnetic wave generated from the insulator when the voltage is applied to the machine. By analyzing the internal and external factors make the electric, mechanic, or thermal characteristics of the electric machinery deteriorate the electric insulation and eventually cause the partial electric discharge. The continuous partial electric charge accelerates the insulation aging and the insulation breakdown happens at last. This system consists of the relays connected with 10 sensors (40 total) detecting the partial electric discharge ans the temperature, the server, ans the program analyzing and storing the data.

  • PDF

고압회전기 절연진단 주기 설정에 관한 연구 (A Study on the Establishment of Insulation Diagnosis Cycle for High Voltage Rotating Machine)

  • 이영준;김희동
    • 대한전기학회:학술대회논문집
    • /
    • /
    • pp.1939-1941
    • /
    • 2000
  • Nondestructive and destructuve insulation tests were performed the high voltage rotating machine in the local thermal power plants. Nondestructive tests include measurements of insulation resistance. polarization index, AC current. tan$\delta$, partial discharge. Destructive tests include measurements of AC hipot and DC hipot. This paper propose to establish the insulation diagnosis cycle for high voltage rotating machine.

  • PDF

Batch Type Back Light Glass Unit 소성 봉착 시스템 개발 (Electric Furnace Sysetem development of Batch Type Back Light Glass Unit)

  • 김수용;이오걸;김상효
    • 대한전기학회:학술대회논문집
    • /
    • /
    • pp.1798-1800
    • /
    • 2001
  • As a batch Type device, this machine is contrive to seal glass plates for plasma BLU (Back Light Unit) by indirect heating from electric heaters. In order to maintain the heating / cooling Chambers clean, this machine uses a muffle formation. The components of the machine are listed bellow.

  • PDF

Power Quality Disturbances Identification Method Based on Novel Hybrid Kernel Function

  • Zhao, Liquan;Gai, Meijiao
    • Journal of Information Processing Systems
    • /
    • v.15 no.2
    • /
    • pp.422-432
    • /
    • 2019
  • A hybrid kernel function of support vector machine is proposed to improve the classification performance of power quality disturbances. The kernel function mathematical model of support vector machine directly affects the classification performance. Different types of kernel functions have different generalization ability and learning ability. The single kernel function cannot have better ability both in learning and generalization. To overcome this problem, we propose a hybrid kernel function that is composed of two single kernel functions to improve both the ability in generation and learning. In simulations, we respectively used the single and multiple power quality disturbances to test classification performance of support vector machine algorithm with the proposed hybrid kernel function. Compared with other support vector machine algorithms, the improved support vector machine algorithm has better performance for the classification of power quality signals with single and multiple disturbances.

Comparative Study of Flux Regulation Methods for Hybrid Permanent Magnet Axial Field Flux-switching Memory Machines

  • Yang, Gongde;Fu, Xinghe;Lin, Mingyao;Li, Nian;Li, Hao
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.158-167
    • /
    • 2019
  • This research comparatively studies three kinds of flux regulation methods, namely, stored capacitor discharge pulse (SCDP), constant current source pulse (CCSP), and quantitative flux regulation pulse (QFRP), which are used for hybrid permanent magnet (PM) axial field flux-switching memory machines (HPM-AFFSMMs). Through an analysis of the operation principle and the series hybrid PM flux regulation mechanism of the objective machine, the circuit topologies and flux regulation process of these flux regulation methods are addressed in detail. On the basis of a simulation, the flux regulation characteristics of the researched machine during the magnetization and demagnetization processes are comparatively evaluated. Then, machine performance, including back EMF, direct and quadrature axis inductances, and magnetization and demagnetization characteristics, is quantitatively investigated. Results show that the QFRP enables the HPM-AFFSMM to achieve a less harmonic component of back EMF by approximately 7.28% and 7.97% at the magnetization and demagnetization states, respectively, and a more complete magnetization process than the SCDP and CCSP.

방전가공에서 전기적 변화가 갖는 방전 특성에 관한 연구 (A Study for its Characteristics with Electric Variation in an Electrical Discharge Machining)

  • 신근하
    • 한국생산제조학회지
    • /
    • v.6 no.4
    • /
    • pp.72-79
    • /
    • 1997
  • A study is a experiment which is figure out to optimum discharge cutting condition of the surface roughness, electronic discharging speed and electrode wear ration with Ton , Toff and V(voltage) as an input condition according to the current(Ip) in an electric spark machine : 1) Electrode is utilized Cu and Graphite. 2) Work piece is used the material of carbon steel. The condition of experiment is : 1) Current is varied 0.7(A) to 50(A) and the time of electric discharging to work piece in each time is 30(min) to 60(min). 2) After the upper side of work piece was measured in radius(5$\mu$m) of stylus analyzed the surface roughness to ade the table and graph of Rmax by yielding data. 3) Electro wear ratio is : \circled1Cooper was measured ex-machining and post-machining by the electronic balance. \circled2The ex-machining of graphite measured by it, the post-machining was found the data from volume $\times$specific gravity and analyzed to made its table and graph on ground the data. 4) In order to keep the accuracy of voltage affected to the work piece was equipped with the A.V. R and the memory scope was sticked to the electric spark machine. 5) In order to preserve the precision of current, to get rid of the noise occured by internal resistance of electric spark machine and to force injecting for the discharge fluid , it made the fixed table for a work piece to minimize the work error by means of one's failure during the electric discharging.

  • PDF

고압중전기기용 절연신소재 EMNC와 EMNSC의 특성연구 (Properties of EMNC and EMNSC for Insulation New Material as Apply to High Voltage Heavy Electric Machine)

  • 박재준
    • 전기학회논문지
    • /
    • v.61 no.10
    • /
    • pp.1454-1460
    • /
    • 2012
  • In order to develop an new electric insulation material for heavy electric equipments, epoxy/micro/nano composite (EMNC) was prepared by mixing micro-silica with nano layered silicate, where the nano layered silicate was synthesized by our electric field dispersion method, EMNSC was prepared by treating the EMNC with a silane coupling agent. Thermal properties such as glass transition temperature (Tg) and thermal expansion coefficient, and DMA characteristics were studied, and mechanicla properties such as tensile and flexural tests were performed. AC electrical insulation strength was also tested. All properties of EMNSC were modified by treating EMNC with silane coupling agent and it was confirmed that our new developed composites could be used in the heavy electric equipments.