Reynolds Number를 변수로한 유동공기의 방전특성에 관한 연구

Characteristics of Sparkover Discharge in Flowing Air with Reynolds Number's Variable

  • 김영훈 (영남대학교 전기공학과) ;
  • 이동인 (영남대학교 전기공학과) ;
  • 이광식 (영남대학교 전기공학과) ;
  • 김상구 (영남대학교 전기공학과)
  • 발행 : 1990.10.01

초록

This paper shows the characteristics of sparkover discharge in flowing air ranging from O(Reynolds number, Re to 10.52$\times$104(Re). Also, we investigated changes of dis-charge pattern for constant input power by adjustment of the Re. The important results obtained from this paper are as followers. The maxinum sparkover voltage of flowing air are about 6.3[kV] higher than those of static air. The discharge pattern can be controlled by adjustment of the Re.

키워드