대형 회전기의 절연진단결과와 경년 특성과의 상관관계에 관한 연구

A Study on the Correlation between the Lapse of Time and Diagnostic Test Results of Large Rotating Machine Windings

  • 김광화 (한국전기연구소 고전압연구실) ;
  • 조연옥 (한국전기연구소 고전압연구실) ;
  • 선종호 (한국전기연구소 고전압연구실) ;
  • 김영배 (한국전기연구소 고전압연구실) ;
  • 류희석 (한국전기연구소 고전압연구실)
  • Kim, K.H. (Korea Electrotechnology Research Institute) ;
  • Cho, Y.O. (Korea Electrotechnology Research Institute) ;
  • Sun, J.H. (Korea Electrotechnology Research Institute) ;
  • Kim, Y.B. (Korea Electrotechnology Research Institute) ;
  • Ryu, H.S. (Korea Electrotechnology Research Institute)
  • 발행 : 1992.07.23

초록

We have done the insulation diagnostic test of generators in domestic five power plants since 1987 and tested A.C. current increasing rate($\Delta$I), $\Delta$tan$\delta$ and partial discharge in generator winding insulation. This study is described the correlation between nondestructive result(A.C. current increasing rate, $\Delta$tan$\delta$ and partial discharge) and lapse of time in generators.

키워드