SH-EMAT에 의한 Digital 신호처리에 관한 연구

  • 김재열 (조선대 정밀기계공학과) ;
  • 박환규 (조선대 정밀기계공학과) ;
  • 조영태 (조선대 대학원 기계설계공학과) ;
  • 김형일 (조선대 대학원 기계설계공학과)
  • Published : 1993.04.01

Abstract

In this study, byusing EMAT(Electro Magnetic Acoustic Transducer) the artificial slit is installed on 12B-SUS pipe test piece. By mading 4 cycle SH-bust wave (EMA) incidence to 45 .deg. angle, the signaldata of pulse, which is recevied from EMAT translated intodigital-signal-processing-method SSP and Deconvolution method by using FACOM. Results of these indicated that (1) this method of this study shows exellent result more than Ultrasonic testing method; (2) noise is well removed by SSP using signal dataa and resolving power and S/N ratio are advanced; (3) regradless of Ultrasonic wave, whichhas properties of generalstainless steel is generated into multiscattering and reflection phenomena, the resolving power of more than two times is progressed by being translated into Decon-volution method; and (4) as addition-averaging-processing number is increaing, the resolving power and S/N ratio are improved and the satisfactory signal is obtained.