Mutual Inductance of the Non-Coaxial Coils in Coil Gun

  • 발행 : 1994.11.18

초록

The purpose of this paper is to describe the mutual inductance between two non-coaxial circular coils in coil gun. As being in many electromagnetic applications, one of them is fixed and the other one is moving and, being not supported, its axis may not coincide with the axis of the fixed coil. This paper presents a method for the calculation of the mutual inductance in case of non-coaxial coupled coils, the characteristics of this inductance and experimental results. For the computation, the complete elliptic integrals formula and mesh matrix technique were introduced. This method enables accurate results from relatively simple procedure and calculation program.

키워드