Novel soft switching FB DC-DC converter for reducing conduction losses

도전손실 저감을 위한 새로운 소프트 스위칭 FB DC-DC 컨버터

  • Published : 1996.07.22

Abstract

The conventional high frequency phase-shifted full bridge DC-DC converter has a disadavantage that a circulating current flows through transformer and switching devices during the freewheeling interval Due to this circulating current, RMS current stress, conduction losses of transformer and switching devices are increased. To alleviate this problem, this study provides a novel circulating current free type high frequency soft switching phase-shifted full bridge DC-DC converter which applies the energy recovery snubber(ERS) attached at the secondary side of transformer. The ERS adopted in this study is consisted of three fast recovery diode($Ds_1$, $Ds_2$, $Ds_3$), two resonant capacitor($Cs_1$, $Cs_2$) and a small resonant inductor [(Lr) : It can be ignored because the transformer leakage inductance(Ll) is able to use in stead of inserting the resonant inductor(Lr)]

Keywords