Evluation of Sensing Performance of Stroke Sensing Cylinder under Various Temperature Conditions

자기센서를 이용한 위치검출 실린더의 온도변화에 따른 성능평가

  • Published : 1996.04.01

Abstract

We developed a part of hydraulic stroke sensing cylinder for te purpose of position controlbyusing magnetic sensor and evaluated variously its performance its performance. In this paper, for the evaluation of the developed cylinder under various temperature change, thermal control systems are designed and controlled. It is composed of an heater case, temperature sensor, and interface circuits which included SCR(silicon controlled rectifier) for the control of the voltage's phase. To obtain various temperature conditions, the thermal systems are controlled by using Ziegler-Nichols PED tuning method. The thermalcontrol systems are used to experiment to evaluate whether the developed cylinder can obtain a stable output signal for detecting a stroke of the cylinder under the controlled temperature condition.

Keywords