A Study on PZT-5A Probe for Nondestructive Inspection
비파괴검사를 위한 PZT 5A 탐촉자에 관한 연구
Abstract
In this study, piezoelectric transducers were designed and manufactured using PZT-5A which had relatively high electromechanical coefficient, NDT system was developed with was able to inspect automatically using stepping motors, PC-Lab, and PC-Scope The optimum design conditions for NDT were presented and verified comparing PZT-5A probes with comercial probes. It was proved with comercial probes. It was proved by simulation and experiments that Epoxy is good as material of matching and backing layers. The envelope was reduced 60% with matching layer and 76% with matching and backing layer. NDT was successfully carried out for aluminum test pieces. Distance error of PZT-5A probe was 2.8%.